ISLA BONITA

ISLA BONITA is a 2012 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2016, most recently in February 2026, along with 126 deficiencies, 12 operational controls, 1 with no removal date recorded and 3 casualty investigations between 2013 and 2023.

Records from 2013 to 2026. Most recent: inspection, 24 February 2026.

Built
2012
Last inspected
24 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Identity

WDG5554
1167874
Flag
UNITED STATES
Maury page id
psix-1167874

Inspections, by type

…with no type recorded2
Years with a record 10 calendar years (2016–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)158.4 ft × 46.0 ft × 11.8 ft
Registered tonnagegross 94 / net 57
ITC dimensions (L × B × D)158.4 ft × 46.0 ft × 11.8 ft
ITC tonnagegross 768 / net 245
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
768 - Convention (Subpart B), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
245 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAYO LARGO Passenger (Inspected) · MISLE 877846 · 15 December 2020 · activity 7116905

Inspection history · 37

24 February 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8314247
30 January 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8071634
18 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7880891
5 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7860475
17 November 2023 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7827523
15 September 2023 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7792272
18 July 2023 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7745240
20 December 2022 Annual Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7610796
3 January 2022 DAPI Audit · Deficiency Check · Administrative Inspection · MTSA Verification · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7364048
15 December 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7116905
25 November 2020 Deficiency Check · Administrative Inspection · Deadweight Survey · Load Line/Change of Employment · Inclining Experiment · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7094979
21 October 2020 Load Line/Change of Employment
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7081714
14 October 2020 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7077738
15 June 2020 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6974637
27 September 2019 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6822497
14 April 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6662095
4 March 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6635823
4 March 2019 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6636025
31 January 2019 Drydock Extension · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6616818
23 December 2018 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6602062
30 November 2018 Drydock Extension · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6590118
24 November 2018 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6585809
31 October 2018 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6571667
24 September 2018 Drydock Extension · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6547509
28 August 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6525568
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512619
27 June 2018 Deficiency Check · Drydock Extension · Internal Structural Exam · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6457747
20 March 2018 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6375473
9 October 2017 Examination of Repairs · Administrative Inspection · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6285408
12 July 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6206921
7 April 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6121184
16 March 2017 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6108099
28 February 2017 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6096345
1 September 2016 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5989902
22 June 2016 DAPI Audit · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5915128
7 March 2016 Administrative Inspection · Construction Oversight · Hull Examination · Internal Structural Exam · Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5828714
28 January 2016 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5804978

Deficiency record · 126

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 February 2026 Resolved
A space containing diesel machinery must be fitted with adequate means, such as dripproof ventilators, ducts, or louvers, to provide sufficient air for proper operation of main engines and auxiliary engines. Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The portside forward ventilation damper louvers was found inoperable. 46 CFR 119.465 (a)/ 46 CFR 119.465 (h) Corrected on the spot 10C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 February 2026 Resolved
All engines must have at least two means for stopping the engine(s) under any operating conditions. The Main Diesel Engines Emergency Stop actuator button at the operating station was found inoperable. 46 CFR 199.200 (b) Corrected on the spot 10C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2026
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2026 Resolved
A door in a stairtower, stairway, and main vertical zone bulkhead must meet the following additional requirements:(i) A door must be of the self-closing type capable of closing against a 3.5 list of the vessel; and(ii) Holdback hooks are not allowed. 05 fire doors were found not closing, 02 did not latched, and two holdbacks were found two plastic cones and one yellow rope to tampering with the door closing operation to hold the door open. 46 CFR 116.435 (6) Corrected on the spot 10C.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2026
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 February 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Both aft port and starboard engine room ventilation ducts and piping insulation lagging were found saturated in oil.46 CFR 119.465.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 26 February 2026
Resolution: All oil was cleaned in both areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2026 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gear temperature gauges for main diesel engines number 3 and 4 (stbd) were found inoperable. 46 CFR 119.410 (b). 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026
Resolved 26 February 2026
Resolution: Both gauges were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 24 February 2026 Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator (RAI) must be independent of control systems for steering gear. The emergency steering rudder angle indicator in the engine room has a difference between 4 to 5 degrees, and needs calibration to read as close as possible to the main RAI at the operating station. 46 CFR 119.600/ 46 CFR 58-25-25. 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 March 2026
Resolved 10 July 2026
Resolution: Calibration was conducted and electronic board was replaced. Certification of calibration provided by a 33rd party contracted electrical engineer.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 February 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The portside forward powered ventilation fan bottom protective guard was found corroded, laying on top of the ventilation louvers. Install missing bottom cover during next dry dock in APRIL 2026. 46 CFR 115.830(a) 705C Next Dry Dock.
Action required: 705 - Other - as specified
Resolved 26 February 2026
Resolution: The motor was replaced for a new one.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 30 January 2025 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system: (a) A space containing propulsion machinery. Hatch door access in the engine room, and both port and starboard engine room escape hatches were found with minor areas that the rubber gasket seal is not making and airtight seal. Properly adjust closing devises, rubber gasket seals and clear hatch coamings of rusted areas that prevents it from sealing. 46 CFR 118.400.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 13 February 2025
Resolution: Rubber gaskets were fixed and able to make a seal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 30 January 2025 Resolved
A hatch exposed to the weather must be watertight. Access hatch deck cover located on top of main diesel engine was found leaking water upon testing with water. 46 CFR 116.1160. Code 17 C, crrected on the spot 10C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2025
Resolution: Corrected on the spot by resealing the hatch cover.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 January 2025 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Port & stbd aft negative ventilation damper fan ducts and louvers were found covered in oil.46 CFR 115.830 (b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 20 February 2025
Resolution: Cleaned and degreased.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 30 January 2025 Resolved
Indication of the rudder angle must be provided both at the main steering station in the pilothouse and in the steering-gear compartment. The rudder-angle indicator must be independent of control systems for steering gear. Rudder angle indicator gauge was found inoperable in the emergency steering at the engine room. 46 CFR 58.25-25 (a).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 13 February 2025
Resolution: Witnessed video of operational rudder angle indicator.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 January 2025 Resolved
The fire detection and alarm system must be so arranged and installed that the presence of a fire in any of the protected spaces will be automatically registered visibly and audibly in the pilot house or fire control station. The visible notice must indicate the zone in which the alarm originated. The vessel fire control panel did not indicate which zone and location in the alarms detected. 46 CFR 118.400(e) 46 CFR 76.27-5(f).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 13 February 2025
Resolution: Tested alarms 14 and 15. Showed number and zone on fire panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared for inspection of each life jacket. 08 adult life jacket with faulty retro tapes and 27 adult life jackets without vessel name marking. 46 CFR 115.808(2).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 13 February 2025
Resolution: New lifejackets were purchased and presented to inspection team.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2025 Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements including: be able to meet the requirements of an A-15 Class bulkhead, and have a latch with a minimum throw of 20 millimeters (0.75 inches). Both port and starboard accommodation fire doors were missing a latch striker plate. 46 CFR 116.435(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2025
Resolved 20 February 2025
Resolution: Latching striker plates have been installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 January 2025 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel. Stbd side rudder tube assembly, underneath the packing gland, was leaking water into the steering lazzarette room through a faulty gasket. 46 CFR 115.814.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2025
Resolved 13 February 2025
Resolution: Stbd side rudder tube no longer leaking. Tested with operation of steering system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Main deck fire doors, and luggage fire doors port and starboard were found with chains and lanyard acting as holdback to ease the access to the these accommodation spaces, but preventing the fire door to close as designed. 46 CFR 115.830 Deficiency corrected on the spot prior finishing the exam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2025
Resolution: Corrected on the spot, holdbacks have been removed prior finishing the exam.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 March 2024 Resolved
Code 02105: The main steering gear must be operable from the pilothouse by mechanical, hydraulic, electrical or other means acceptable by OCMI. This gear and its component must give full follow-up control of the rudder. Operating station main steering device (wheel) was found inoperable. Prove proper operation of main steering device within 7 days. Is not corrected in 7 days, deficiency will change to code 17 (prior to departure). 46 CFR 115.814 Code 705C (7 days, due 04APRIL2024).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 April 2024
Resolved 4 April 2024
Resolution: Once the cards were installed in the correct sequential order, the inputs in the helm were interpreted by the potentiometer (sender units) hence moving the steering rudders
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2024 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. During testing of the CO2 Fixed fire extinguishing system, all 4 main diesel engines and both port and starboard generators failed to shut off. Prove proper operation of main diesel engines and main diesel generators shut-off during the testing of the Co2 Fixed Fire Extinguishing System to the satisfaction of an attending USCG Marine Inspector. 46 CFR 118.410(b)(10).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2024
Resolution: Tested two times successfully the engine shut-off during the simulated activation of the CO2 fixed gas system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 March 2024 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Steering pumps testing could not be carried out due to a problem with steering pump number two, and rudder angle indicator set at 45 degrees port, while all rudder angle indicators at the operating station are indicates midship cero degrees. Prove proper operation of both #1 and #2 steering pumps from local controls at the emergency steering in the engine room, and from the operating station; including the proper operation of the rudder angle indicators. 46 CFR 115.814 Code 17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 March 2024
Resolution: Tested both pumps successfully.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 March 2024 Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. (2) Protection of passengers, crew, other persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved. Multiple electric cables were found cut, and not being connected to an equipment, nor protected in an electrical protection box for the operating station deck lighting panel. 46 CFR 111.01-1, Code 16C.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 26 March 2024
Resolution: All dead-end wires have been removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2024 Resolved
CO2 locker relief valve is painted over on main bulkhead weather main deck. 46 CFR 115.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 27 March 2024
Resolution: Paint was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2024 Resolved
Verify CO2 system operational before carriage of pax. Bottles are being serviced in Puerto Rico. Key and break glass are not on board. 46 CFR 115.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 27 March 2024
Resolution: Witnessed the servicing of CO2 cylinders, and a new box with the keys was installed in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 February 2024 Resolved
Demonstrate operation of firefighting system valve within HVAC compartment forward main passenger cabin. 46 CFR 115.810
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2024
Resolved 27 March 2024
Resolution: Valve was repaird and retested satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 July 2023 Resolved
11110 - Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Inspector noticed 03 inflatable life rafts on the to deck did not have their weak link attached properly. In the case that the vessel sink, those life rafts would have sank with the ship and not automatically disconnected as intended. 46 CFR 117.130 (a)(2) 10C
Action required: 10 - Deficiency Rectified
Resolved 18 July 2023
Resolution: Operator fixed weak links by reattaching them properly. Def cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2023 Resolved
11117 - Each ring life buoy on a vessel must be approved in accordance with 46 CFR 169.050 Subchapter Q. Inspector noticed starboard midship aft ring life buoy was missing the plug, starboard midship ring life buoy reflective tape was wasted. 46 CFR 117.70 (b) (1) 10C
Action required: 10 - Deficiency Rectified
Resolved 18 July 2023
Resolution: Operator replaced new ring life buoys with a fully serviced extra one that was stored on the vessel locker and put reflective tape to the wasted one. Def cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 December 2022 Resolved
At each inspection the operator shall have the vessel ready for testing of smoke and fire detecting systems. Heat detectors were unable to be tested. Provide manufacturer instructions and means to test heat detectors.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2023
Resolved 27 January 2023
Resolution: Rcvd email correspondence from the company in the form of photos and videos correcting deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 December 2022 Resolved
Nonmetallic piping materials must meet the requirements of 46CFR56.60-25 and SAE J1942. 02 lube oil hoses were chaffed on the port side outboard engine and require replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2023
Resolved 27 January 2023
Resolution: Rcvd email correspondence from the company in the form of photos and videos correcting deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 December 2022 Resolved
At each inspection the operator shall have the vessel ready for inspection of its fire protection equipment. 01 heat detector between number 1 and 2 port engines requires remounting.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2023
Resolved 27 January 2023
Resolution: Rcvd email correspondence from the company in the form of photos and videos correcting deficiency.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 20 December 2022 Resolved
The station bill must set forth the special duties and duty station of each crew member listed on the certificate of inspection for various emergencies. Multiple station bills found on board that failed to address each crew member’s duties during an emergency.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 January 2023
Resolved 27 January 2023
Resolution: Rcvd email correspondence from the company in the form of photos and videos correcting deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2022 Resolved
Electrical installations shall be installed to protect crew from electrical hazards. A circuit breaker was missing on the port side electrical panel located in the main passenger deck area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Verified installation of breaker cover on electrical panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 January 2022 Resolved
Electrical installations shall be installed to protect crew from electrical hazards. Address electrical cables on the #2 & #3 MDE (Aft). The electrical cables are not connected to anything or have any apparent use.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Verified that cables were removed/secured.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 6 January 2022 Resolved
A fire control plan must be posted on the vessel on a location that is accessible and visible to all passengers. The plan must be current. The attending marine inspectors noticed that the currently approved fire control plan is not current and needs updating. Make proper corrections and submit to the OCMI for local approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Fire control plan was approved at the local OCMI level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 January 2022 Resolved
Prove satisfactory function of MDE’s High Jacket Water and Low Lube Oil Alarms. Provide objective evidence that the test were conducted during dry dock OR have the tests conducted IAC/w manufacturer specifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 20 December 2022
Resolution: Satisfactory evidence of alarm testing was provided.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 6 January 2022 Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers. The employer may establish the EAP as part of its internal personnel services or the employer may contract with an entity that will provide the EAP services. Each EAP must include education and training on drug use for crewmembers and the employer’s supervisory personnel as provided in 46 CFR 16.401. The crew was unfamiliar with testing location of the closest specimen collection facility, and unfamiliar with the employer’s Employee Assistance Program. Conduct EAP training for all crewmembers and provide evidence of training for the satisfaction of the USCG
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Trainings had been conducted.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 January 2022 Resolved
A framed chart or diagram shall be installed in the wheelhouse or control station adjacent to the detecting cabinet indicating the location of the various detecting zones and giving instructions for the operation, maintenance, and testing of the system. U.S. Coast Guard inspector found that there is no Fire Detection Diagram or chart posted at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Diagram and booklet were posted at the operating station.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 January 2022 Resolved
The Cognizant OCMI may require that a vessel and its equipment undergo additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. The “low battery” voltage led light for the watertight door control panel located at the bridge was found to be inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Watertight door panel at bridge was operating properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 January 2022 Resolved
The owner and operator of a non-tank vessel response plan must review the vessel response plan (VRP) annually. A VRP prepared and submitted must be revised and amended as necessary in accordance with 155.1070. The Non-tank Vessel Response plan last update was YR2014 and all points of contacts responsible of the plan are not current. Conduct a review of the Vessel Response Plan and submit the amendments for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 27 March 2024
Resolution: An updated version of the NTVRP was found on board.
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Ship security plan
Issued 6 January 2022 Resolved
Each vessel owner or operator must designate in writing a Company Security Officer (CSO). The Vessel Security Plan’s listed CSO is no longer an employee of the company. Provide a current CSO letter of designation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 5 October 2022
Resolution: The CSO was updated and VSOs are aware of the change and have the contact information.
16 - International Ship & Port Facility Security (ISPS) › N/A - No Subsystem › Ship security plan
Issued 6 January 2022 Resolved
If the owner or operator has changed, the Vessel Security Officer (VSO) must amend the Vessel Security Plan to include the name and contact information of the new vessel owner. USCG marine Inspector found that the Vessel Security Plan placed on board was not updated and contained information that was not current.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 20 December 2022
Resolution: Secuirty plan was updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 January 2022 Resolved
A vessel must comply with the minimum manning specified on the Certificate of Inspection. Vessel was found not having a letter of designation for a Senior Deck Hand. Provide a Letter of Designation for Senior Deckhand as required by the Certificate of Inspection or a licensed mate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Senior deckhand letter of designation was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 6 January 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. The modified deck plate over the shaft on the #2 MDE contacts the shaft while in motion. Modify deck plate to ensure it does not contact the shaft.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Deck plates have been reinstalled so that they don't make contact with shaft.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 January 2022 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable. Structural fire protection insulation was falling off on the port side emergency escape from the engine room.
Action required: 10 - Deficiency Rectified
Due 2 February 2022
Resolved 16 March 2022
Resolution: SFP was properly replaced and installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 January 2022 Resolved
Detectors must be capable of being triggered or tested and restored to service without the replacement of any component. No smoke or method for testing detectors was available on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2022
Resolved 16 March 2022
Resolution: Smoke cannister was made available and several smoke detectors were satisfactorily tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Identify coolant leak on #1 MDE turbocharger. Provide corrective action and conduct sea trials in the presence of the attending marine inspector.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2022
Resolved 4 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2021 Resolved
Holdback hooks are not allowed on A-Class fire control boundary doors. Both passenger space access doors on main deck have holdbacks. 46 CFR 116.435(c)(6)(ii)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2021
Resolved 3 December 2021
Resolution: Holdbacks removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 November 2021 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side. Main deck doors with locks have no means to unlock from the inside. 46 CFR 116.500(i)
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 November 2021
Resolved 3 December 2021
Resolution: Internal lock releases installed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 September 2021 Resolved
Each accommodation space, control space, and service space must be fitted with a smoke actuated fire detection system of a type approved by the Commandant that is installed in accordance with 46 CFR part 76. Port and stbd luggage spaces on main deck do not have fire detection systems. 46 CFR 118.400(e)
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 September 2021
Resolved 3 December 2021
Resolution: Installed fire detection.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 October 2020 Resolved
Alterations to the equipment of the vessel must not be made without the approval of the cognizant [name withheld] that affect the safety of the vessel include alteration of lifesaving equipment. U.S. Coast Guard Inspectors found two large life jackets storage cabinets made of aluminum in both port & starboard main deck passenger accommodation, close to both only main access doors; and a large aluminum storage bin containing life jackets in the second deck outside of the passenger accommodation, next to the stairways. Submit plans or drawings containing the modifications made for the approval of the U.S. Coast Guard Marine Safety Center. If this deficiency is not cleared within 30 days (Code 50) from the date of issuance, it will automatically will be reclassified to Rectify Deficiencies Prior to Departure (Code 17).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 January 2022
Resolution: Plan has been amended to include new life jackets storage cabinets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 16 April 2019 Resolved
Vehicle decks on a vehicle ferry must be subdivided. Where main vertical zones are impractical due to the vehicle carrying configuration, main horizontal zones may be provided. The decks bounding such a zone must be of at least A–30 construction or meet the requirements of paragraph (c) of this section, whichever is greater. Insulation above #1 & #2 MDE were found to be salt water saturated from non-watertight deck plugs for the cooling water deck plugs.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Plugs welded.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 April 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in the hull, decks, and bulkheads. The watertight bulkhead door leading down into the passageway leading to the engine room was not able to be properly secured.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Door repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 April 2019 Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a watertight trunk that extends at least 305 millimeters (12 inches) above the weather deck. The hatch to the starboard steering gear compartment is not weathertight. In addition, the portside engine room escape hatch can’t be secured due to possible misalignment of the hatch or some other different condition that needs to be addressed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Hatch repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 April 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Inspectors found two of the four deck plugs for the cooling water filling port to have missing threads and making them non-watertight.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Plugs repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, aterials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The #1 shaft was found to be leaking at approximately one gallon per minute and the #2 and #3 shafts were missing double nuts.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: All four Shafts Packings have been replaced new and no water intrusion was found.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2019 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Oil soaked wiring was observed under two of the MDEs, oil soaked absorbent pads were also observed under the MDEs, oily water was found in the #1 MDE fuel filter flame bowl, and machinery space bilges had a coating of oil in numerous areas.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: Engine room was found with an acceptable bilge oily water level and no rags found in the bilges. No trash was found in the engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2019 Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail. Oily waste pump was missing guard around rotating shaft.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 April 2019 Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. All MDE turbos were found without any lagging.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 December 2021
Resolution: Lagging installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2019 Resolved
At least one ring buoy must be fitted with a floating waterlight. The ship has two floating waterlights aft of the navigation bridge with batteries that are marked have to expired on November 2018.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: Waterlights have been removed as the vessel is out of operations with no passengers on board, Vessel is going for dry dock and a COI inspection will be conducted prior returning for service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019 Resolved
Life jackets must be stored in convenient places distributed throughout accommodation spaces. The ship’s procedure is to stow life jackets under passenger seating. The general arrangement plan indicates seating/accommodation for 218 passengers on the first deck; however, only 173 life jackets were stowed under the seats, leaving 45 missing from designated stowage positions.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: A new lifejackets racks have been installed in the back of the main deck at each port and stbdsides that will resolve the problem of missing lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 April 2019 Resolved
Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft. One of the launching instructions was so faded as to be nearly illegible in broad daylight.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 January 2022
Resolution: Placards have been installed in the IBAs cylinders.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 April 2019 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. Three of the ship’s ring life buoys were missing manufacturer specification plugs to prevent water ingress and degradation of buoyant material. One of these ring life buoys was stuffed with a paper napkin in the plug hole.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: All life rings have been removed as the vessel is not in operation, a new set of liferings will be placed for passenger service after dry dock.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 April 2019 Resolved
Each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door. The two required means of escape must be widely separated and, if possible, at opposite ends or sides to minimize the possibility of one incident blocking both escapes. Each door, hatch or scuttle, used as a means of escape must be capable of being opened by one person from either side. The method of opening a means of escape must be rapid and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door or hatch must open towards the expected direction of escape from the space served. The escape hatch located on the portside steering room was blocked with a round piece of steel on top of the hatch, which prevented the means to exit through the hatch, forcing him to return and exit through the starboard side hatch for which he entered in the first place.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: Means of escapes in both port & stbdside steering room were found free of obstructions.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 April 2019 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. There are no records of fire fighting drills onboard and the master could not recall the last time drills had been performed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: Vessel has been out of operation and no passengers for hire have been conducted. Upon return from dry dock a new COI inspection will be conducted and drills must be carried out.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 April 2019 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. There are no records of abandon ship and man overboard drills onboard and the master could not recall the last time drills had been performed.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 23 October 2020
Resolution: Vessel has been out of operations and no passengers for hire. Vessel must undergo a new COI exam upon returniog from dry dock.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 16 April 2019 Resolved
The station bill of a vessel of more than 19.8 meters (65 feet) in length required to have more than four crewmembers, must set forth the special duties and duty station of each crewmember for various emergencies. The crew onboard did not know what a station bill is and therefore were unfamiliar with their station bill emergency duties.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 January 2022
Resolution: A new station bill was posted and crewmembers showed proficiency in implementing the designated roles.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 April 2019 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. U.S. Coast Guard marine inspector did not find any navigation chart to scale or updated, accessible at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Vessel crew taking the vessel for dry dock will provide teir own charts and navigation equipment for the voyage.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 16 April 2019 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant OCMI. The anchor hold was excessively corroded, preventing it from being ratcheted loose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Proved proper operation of the nchor motor winch by launching and retrieving the anchor.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 April 2019 Resolved
A framed chart or diagram shall be installed in the wheelhouse or control station adjacent to the detecting cabinet indicating the location of the various detecting zones and giving instructions for the operation, maintenance, and testing of the system. This chart, or separate card or booklet to be kept near the chart, shall have tabulated spaces for the date and signature of the licensed officer of the vessel who shall witnessed or conduct the periodic test. In addition, a fire control plan must be posted on the vessel in a location that is accessible and visible. The plan must show escape routes, areas of refuge, embarkation statins, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and services spaces, and structural fire protection boundaries. U.S. Coast Guard inspector found that there is no Fire Detection Diagram or chart posted at the operating station, nor did the vessel captain have knowledge that the diagram was in a binder on board the vessel. In addition, the fire control plan located in the lower passenger deck was found to be faded due to water or moisture intrusion, damaging the impression and making it unreadable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2022
Resolution: This deficiency has been re-issued in a new deficiency 03JAN2022 (activity 7364048).
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 16 April 2019 Resolved
The vessel owner or operator must ensure that they maintain one English language copy of the VRP, at a minimum the contents listed in paragraph (c)(1), (2), (3), (5), (6), (7), (9) and (10) of this section and a copy of the Coast Guard approval letter, onboard the vessel. Vessel has no copy of the NTVRP onboard.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: A copy of the NTVRP plan was found on board in the documents binder.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019 Resolved
The stop valve or the stop-check valve is accessible for both manual operation and repair under all operating conditions, and the space used for access contains no expansion joint or flexible coupling that, upon failure, would cause flooding and prevent access to the valve. The bilge suction valve in the #3 port void space is seized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Bilge suction valve was re-tested and found fully operational
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2019 Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. U.S. Coast Guard inspector found that the currently displayed Certificate of Inspection is a copy and is not the most current issued certificate for this vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 October 2020
Resolution: Vessel is out of passenger service, pending for dry dock, upon returning from Dry Dock a new COI inspection will be conducted and new COI will be issued.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 April 2019 Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part. The master was unfamiliar with required serious marine incident testing requirements and the location of the closest specimen collection facility, and the master and crew were unfamiliar with the employer’s Employee [name withheld] indicating noncompliance with 46 CFR 16.401. A DAPI audit is required.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 January 2022
Resolution: A new deficiency was issued for EAP program training. Master proof proficiency in reporting procedures.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 April 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The vessel’s first aid kit is missing aspirin and bandages.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 October 2020
Resolution: Vessel has been out of service pending for Dry Dock. A new COI inspection will be conducted and first aid kit will be verified during COI Inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 April 2019 Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: (i) A self- propelled vessel of 65 feet or more in length, engaged in commercial service. The vessel was not broadcasting an IMO number, Zero Length or Beam, No dimension information for any of the antennas, Zero Draft and no static draft information.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 January 2022
Resolution: AIS was found to be operating normally.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 16 April 2019 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. The cross connect valve for the oily waste tanks was seized and unable to open.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2021
Resolution: Valve repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 April 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The #1 engine high exhaust temperature alarm is activated whenever the captain tries to run at 1,400 RPM, and the vessel was taken out of service. The operator must prove proper operation of the #1 engine prior to getting underway to the satisfaction of the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2021
Resolution: Engine renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 March 2019 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's main diesel engine number 4 has a transmission failure preventing normal operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2019
Resolved 5 March 2019
Resolution: Clutch was replaced and routine maintenance was preformed on the transmission.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 December 2018 Resolved
Vessel's #1 MDE will not clutch into forward. Properly repair to the satisfaction of the local OCMI the proper operation of the #1 MDE prior to departure. Vessel allowed to sail one time from ATM terminal in Ceiba to ATM Facilities in Fajardo to complete the repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2019
Resolution: Clutch was replaced. Sea trials were observed with no issues noted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2018 Resolved
A crew member must man the engine room serving as fire patrol watch and report the captain that no fire is found. Vessel captain must log it in the vessel log in 15 minutes intervals. Properly re-install missing heat detector #2-6 at the engine room, test all 4 detectors and fire control panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 4 March 2019
Resolution: Received fire technician system report attesting that the heat detector was replaced and the fire detection panel was found operational after being re-programmed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 24 September 2018 Resolved
Each individual bilge suction shall be fitted with a suitable bilge strainer having an open having an open area of not less than three times at the suction pipe. A bilge suction pipe located forward of the sliding watertight at the engine room was found with the strainer disconnected of the pipe. Properly repair or replace the strainer back into the bilge suction.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 2 October 2018
Resolution: Bilge strainer was re-installed properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 September 2018 Resolved
The termination of each battery cable must be sealed to prevent the entrance of electrolyte by spray or creepage. The battery cables which provide charge to Main Diesel Engines numbers 3 and 4, were found to be worn and damaged, exposing the wires. Properly replace the damaged cables with new ones that meets the Code of Federal Regulation to the satisfaction of an attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2018
Resolved 2 October 2018
Resolution: Cables were replaced with integral cables.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 August 2018 Resolved
Code 04103: Each fully charged lead-acid battery must have a specific gravity that meets section 22 of IEEE 45-2002. Battery charger on # 1 and #2 Main Diesel Engines starting batteries is showing it is running at 10 Amps when batteries have not been in use. Check all batteries to find if batteries have a bad cell and replace batteries if necessary and report to the USCG which ones have been replaced. 46CFR 111.15-2(b) 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 28 September 2018
Resolution: One battery was replaced, including the battery charger.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 August 2018 Resolved
Code 04103: Batteries must be mounted in tray lined with, or constructed of, a material that is resistant to damage by the electrolyte. Properly mount both batteries boxes for port and starboard-side diesel generators. 46CFR 120.350(e) & 111-15.5(d) 50C.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 28 September 2018
Resolution: All batteries were found to be inside of tray liners.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 August 2018 Resolved
Code 04103: The emergency lighting must automatically actuate upon failure of the main lighting system. Replace the emergency lights identified in the engine room failed to operate upon testing the emergency lighting system. 46CFR 120.432 (a) & (b) 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 28 September 2018
Resolution: Emergency lighting was found to be repaired and in working order upon testing.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 August 2018 Resolved
Code 07122: Fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. Provide and make visible as required the missing section of the fire control plan, as is listed in the location of the remaining plan on board.46CFR116.530/ 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 January 2022
Resolution: Deficiency has been re-issued on a new CG835V (activity 7364048).
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 August 2018 Resolved
Code 07122: The owner and operator of a non-tank vessel response plan must review the vessel response plan (VRP) annually. A VRP prepared and submitted must be revised and amended as necessary in accordance with 155.1070. The Non-tank Vessel Response plan last update was YR2014, conduct a review of the Vessel Response Plan and submit the amendments for approval to Commandant (CG-CVC-1), Attn: Vessel Response Plans, U.S. Coast Guard Stop 7501, 273 [name withheld] King Jr. Avenue SE., Washington, DC 20593-7501 or via Email https://homeport.uscg.mil/vrpexpress. 33CFR155.5065 & 5070.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 January 2022
Resolution: Deficiency has been re-issued in a new CG835 V (Activity 7364048).
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 August 2018 Resolved
Code 0511: The master of the vessel shall ensure that the EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that is operative and test shall be logged or otherwise documented. No EPIRB's testing has been conducted in months, Conduct monthly EPIRB testing and recorded in the log.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 28 September 2018
Resolution: Epirb was last tested and logged on 08SEPT28018.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 30 August 2018 Resolved
Code 10133: The Station Bill must be posted at the operating station. Crew must familiarize and know their assigned duties in accordance with the emergency procedures as indicated in the Station Bill. Provide and post the Station Bill for the view of all crew and conduct training for the required duties as indicated in the Station Bill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 28 September 2018
Resolution: During the ISE crew members on board were questioned about the duties assigned in the station bill and the responses were found in accordance with the current station bill.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 30 August 2018 Resolved
Code 15113: Employee Assistance Program training must be conducted for the employer's crew members and supervisory personnel. The training must include at least: effects and consequences of drug and alcohol use on personal health, safety, and work environment: the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crew members and the employer's supervisory personnel. Upon request, no proof of training was provided and crew upon questioning provided contradictory information on how the current EAP program works. Conduct EAP training and provide evidence that training has been given. 46 CFR 16.401/ 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 January 2022
Resolution: Deficiency has been re-issued in a new CG835V (activity 7364048).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 30 August 2018 Resolved
Code 15113: The Marine employer shall ensure that all individuals engaged on employed on board the vessel are fully indoctrinated in the requirements of 46CFR4.06-1 & 4.06-3. None of vessel or shore personnel knew the process or who is the employee representative was. 46CFR 4.06/ 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 3 January 2022
Resolution: This deficiency has been cleared as a new deficiency requiring DAPI and EAP training must be provided, on which this topic will be covered.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2018 Resolved
Code 10113: An AIS class A device must be installed on self propelled vessels of 65 feet or more in length, engaged in commercial service and must be operational. Vessel is broadcasting no IMO number, zero length or beam, no dimension information (AIS antenna Position ABCD values equals 0), zero draft, no static draft information as notified by the USCG Navigation Center. Properly conduct an AIS system assessment and conduct corrective actions to prove proper operation of the vessel AIS system. 33CFR 164.46/ 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2018
Resolved 28 September 2018
Resolution: A local comms techinican attended the vessel and checked the unit. Checked the USCG NAVCEN Webstie and Marine Traffic Website and found that discrepancies issued by the NAVCEN were corrected. Vessel has no IMO number, only official number.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 22 February 2019
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 29 May 2018 Resolved
08107-At each subsequent inspection of a vessel, the owner/operator shall be prepared to conduct inspection of all machinery essential to the routine operation of the vessel, including the test of machinery alarms. Main Diesel Engine Number 4 was found with an alarm indicating a fault (error) in the crank case oil pressure sensor previously replaced with a new sensor. However, the the alarms is still active, indicating a different problem that needs to be resolved. Provide a corrective resolution of the problem and prove proper operation during sea trials. 46CFR115.804(1).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 29 June 2018
Resolution: Conducted a test on the engine and found no code or alarm being displayed. Cable connecting the sensor was replaced and connection was cleaned.
Electrical › Electric Generation Source (service) › Generator
Issued 21 March 2018 Resolved
Electric equipment on a vessel must be maintained to provide services necessary for safety under normal and emergency conditions. Prove proper operation of port side generator which failed to operate. 46CFR120.220(a) & 115.804(c). Prior Carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Resolution: Witnessed the proper operation of the generator for more than 3 hours.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 21 March 2018 Resolved
At each subsequent inspection of a vessel, the owner/operator shall be prepared to conduct inspection of all machinery essential to the routine operation of a vessel cooling systems. Main Diesel Engine #4 was found with an alarm indicating a fault in the crank case sensor, Properly correct the cause of the problem as indicated by the alarm and prove proper operation of main diesel engine #4. 46CFR115.804(i). Due in 7 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 29 May 2018
Resolution: Deficiency was re-issued in a new CG835V as a different problem was found in this particular engine and with the same sensor.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 March 2018 Resolved
At each subsequent inspection of a vessel, the owner/operator shall be prepared to conduct inspection of all machinery essential to the routine operation of a vessel cooling systems. Main Diesel Engine #2 was found to have multiple alarms indicating a high temperature of the exhaust gas system. Properly correct the cause of the problem as indicated in the alarms and prove proper operation of main diesel engine #2. (46CFR115.804(c) and 119.200(a). Prior Carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Resolution: Witnessed the proper operation of engine during sea trials for 1 hours approximatly and no signs of alarms were displayed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 March 2018 Resolved
At each inspection all observed unsafe practices must be corrected and must be in satisfactory conditions. Mechanics indicated that all 4 main diesel engines were 11,000 hrs overdue for maintenance and engine #2 was being operated at lower RPMs to prevent overheating. Conduct maintenance in all engines in accordance with engine manufacturer's instructions, following a statement from vessel chief of mechanics that all engines are over 11,000 hrs overdue for maintenance. 46CFR115.830 & 800. Prior Carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2018
Resolution: Vessel owner/operator performed an extensive maintenance on all four main diesel engines.
Engineering › Bilge Water Management System › Pump
Issued 20 March 2018 Resolved
Prove proper operation of bilge pump after finding the seal and connecting shaft from the pump to the centrifugal to be broken.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2018
Resolution: Conducted operational test of repaired bilge pump with new connected link/coupling by emptying the collision bulkhead which was filled with fresh water. Successful operational test.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 20 March 2018 Resolved
13101-At each subsequent inspection of a vessel, the owner/operator shall be prepared to conduct inspection of all machinery essential to the routine operation of a vessel. The Main Diesel Engine number 1 was found to have a severe oil leak located between the crank case and the engine block. Properly correct the cause for the oil leak and prove proper operation during sea trials. 46CFR115.804
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2018
Resolution: Witnessed the proper operation of main diesel engine under load during sea trials an no evidence was found of oil leaks coming from the crank case pan.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 October 2017 Resolved
FCC Radio Safety & Vessel Bridge-to-Bridge Certificate must be renewed and valid, vessel is restricted to not more than 1,000 FT from shore. 46CFR121.502.
Action required: 705 - Other - as specified
Resolved 20 October 2017
Resolution: A new FCC Radio Safety Certificate and Vessel Bridge to Bridge Safety Certificate have been issued to the vessel by a local FCC authorized technician (CRT Coomunications [name withheld].
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 10 October 2017 Resolved
Prove proper operations on both port & stbdside bridge wings rudder agnle indicators. 46CFR58.25-25.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2017
Resolved 27 December 2017
Resolution: Tested all rudder angle indicators on the navigation bridge satisfactorily.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 10 October 2017 Resolved
Replace anchor chain and windlass rope wire. 46CFR122.320.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2017
Resolved 27 December 2017
Resolution: Verified that new anchor wire was installed and old one was removed.
Fire Fighting › Fire Main › Condition
Issued 10 October 2017 Resolved
A path was found in fire main piping, replace with an integral pipe as in kind. 46CFR119.710.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 December 2017
Resolved 27 December 2017
Resolution: New section of fire main piping was inspected and tested.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 10 October 2017 Resolved
Voyage Data Recorder must be serviced and certified in accordance with manufacturer's instructions and recommendations.46CFR115.816.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 22 March 2018
Resolution: Vessel is not required to have a VDR due to the route that is currently operating IAW with their current COI. Deficiency has been cleared due to lack of applicability for a SVDR.
Fire Fighting › Fire Main › Condition
Issued 7 April 2017 Resolved
Repair fire main pipe rupture located at the engine room. 46CFR 118.310 & 119.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2017
Resolution: Section of pipe that was wasted and a new section was welded in place. Performe a fire pump pressure test, no leaks detected and all fire hydrants were tested satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 7 April 2017 Resolved
Repair bilge pipe rupture located at the engine room next to the pump. 46CFR119.510 & 119.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: A new flange and valve was installed in place. Bilge pump tested sat.
Fire Fighting › Fire Hoses › Condition
Issued 7 April 2017 Resolved
Prove propr operation of all exterior fire hydrants, fire hoses and nozzles.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2017
Resolution: all exterior fire hoses were replaced for new ones, all fire hydrants, including the ones in the interior of the vessel and engine room were tested under pressure satisfactory.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 17 March 2017 Resolved
Correct excessive water intrussion on shafts #4, #3, #2.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2017
Resolution: Corrected on the spot, all packing seals were replaced with new seals and packing glands were adjusted until excessive water intrussion was controlled to a normal drip flow.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 17 March 2017 Resolved
Properly correct overload alarm on steering panel in accordance with manufacturer's instructions.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: The overload alarm was corrected, no visual alarms was found after performing steering sea trials.
Engineering › Steering Gear System › Rudder
Issued 17 March 2017 Resolved
Properly correct excessive water intrusion on faulty seals and packings in both port and starboard steering posts.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Packings were replaced and packing glands were adjusted.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 March 2017 Resolved
Remove excessive bilge water in both engine and steering rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2017
Resolution: Corrected on the spot, a total of 6 drumms of fifty gallons were removed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 March 2017 Resolved
Access door leading to the cargo deck on portside must meet A-60 in accordance with Fire Control Plan, vessel is restricted of carrying fuel trucks.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Inside pannel was repaired as in kind, restriction has been released.
Engineering › Steering Gear System › Trick Wheel
Issued 17 March 2017 Resolved
Properly secure steering drive wheel that secures the wheel to the control station.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 17 March 2017
Resolution: Corrected on the spot, a total of 3 screws were lose.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 March 2017 Resolved
VHF radio must be connected to a GPS Receiver IAW 47CFR. Vessel was issued this deficiency during COI on June 2016 and failed to correct it.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: Both VHF radios were found to be connected to a GPS, showing coordinates and MMSI numbers entered.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 March 2017 Resolved
Wiring on all four main diesel engines must be installed with metal supports spaced not more than 24 inches apart and as high of the bilges as practicable.
Action required: 705 - Other - as specified
Due 24 March 2017
Resolved 24 March 2017
Resolution: All electrical wiring underneath the engines were secured with metal hangers and 24" apart, above the bilges on all 4 main diesel engines.
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 17 March 2017 Resolved
Sensors indicating open/close position for the following compartments, hatches and doors must be replaced and prove proper operation: a. stern loading ramp; b. bow thruster hatch; c. port & stbd steering room hatches.
Action required: 705 - Other - as specified
Due 17 April 2017
Resolved 24 March 2017
Resolution: All sensors were either replaced (loading ramp) and the rest were re-adjusted to show open/close by adjusting the indicator bar connected to sensors.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 16 March 2017 Resolved
Prove proper operation of Main Diesel Engine # 2 (port-inboard).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2017
Resolution: Main ECU computer was replaced at the engine, performed sea trial and was found operational, no alarms or codes were displayed.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 28 February 2017 Resolved
Provide a repair proposal to address the repair or replacement of port-outboard main diesel engine and associated modifications required to the main deck for engine access. In addition, prove proper operation of main diesel engine to the satisfaction of an attending USCG Marine Inspector IAW 46CFR119.100 & 119.200(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2017
Resolution: Vessel was able to repair transmission casing without removal of engine or shafts.
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 September 2016 Resolved
Sentinel System control panel with bilge alarms was not found working, Prove proper operations.IAW 46 CFR 128.220 & 46 CFR 62.25-20.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: Tested the communications panel and tested the bilge alarms and all was found to be in good operating service.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 June 2016 Resolved
Demonstrate to Sector San [name withheld] that vessel can serve as own rescue platform as per 46 CFR 117.210
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2016
Resolved 12 July 2016
Resolution: Witnessed successful Man Overboard drills.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 June 2016 Resolved
Prove that DSC function is correctly connected on all VHF radios.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 28 June 2016
Resolution: Proved proper operation of DSC function on all VHF radios.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 June 2016 Resolved
Vessel must complete drills upon arrival back to Puerto Rico 46 CFR 122.520 & 524
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 12 July 2016
Resolution: Conducted satisfacotry fire and man overboard drill.
Lifesaving › Rescue Boat › Construction
Issued 7 June 2016 Resolved
Demonstrate that vessel can act as own rescue boat to local OCMI 46 CFR 117.210
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 12 July 2016
Resolution: Conducted satisfacotry man overboard drill where the attending marine inspectors concluded that vessel can act as its own rescue boat.
Construction/Loadline › Structures › Door
Issued 7 June 2016 Resolved
Sliding Class III WTD would not operate properly. 46 CFR 122.330
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2016
Resolution: Batteries were replaced. Completed a function test from local and both remote operation stations. Test was sat.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 June 2016 Resolved
Install non-conductive mat or grating in front of switchboard. 46 CFR 120.330(g)
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 June 2016
Resolution: Crew installed non-conductive mat in front of switchboard.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 June 2016 Resolved
Both frequency meters would not operate properly. 46 CFR 120.330
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 22 June 2016
Resolution: Witnessed proper operation of both frequency meters.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 June 2016 Resolved
Demonstrate to local OCMI that the DSC function on all VHF radios is connected correctly.
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 12 July 2016
Resolution: Conducted satisfactory man overboard drill. Cleared deficiency.

Casualty record · 3

6 October 2013Routine · role: Involved in a Marine Casualty · activity 4736202
15 December 2020Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7116905
15 September 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7792272
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.