← All vessels
ROGER WHITE
Offshore Supply Vessel · Offshore class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named ROGER WHITE
ROGER WHITE is a 2012 offshore supply vessel. The Coast Guard has recorded 24 inspections since 2012, most recently in June 2026, along with 21 deficiencies and 1 operational control.
Records from 2012 to 2026. Most recent: inspection, 3 June 2026.
- Built
- 2012
- Last inspected
- 3 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1240194
9529994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG4445
1173896
Flag
UNITED STATES
366017000
Maury page id
psix-1173896
Inspections, by type
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Registered dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,242 / net 1,447
ITC dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,242 / net 1,447
BuilderGULF SHIP LLC · GULFPORT, MS, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7549 - Displacement, Gross Ton
4942 - Dead Weight, Gross Ton
3242 - Convention (Subpart B), Gross Ton
1447 - Convention (Subpart B), Net Ton
4942 - Dead Weight, Gross Ton
3242 - Convention (Subpart B), Gross Ton
1447 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
EX350MMSI 366017000 · active · exemption · granted 11 December 2025, expires 11 December 2029
EX327MMSI 366017000 · expired · exemption · granted 16 December 2024, cancelled 20 December 2025
WDG4445MMSI 366017000 · active · compulsorily equipped · granted 6 April 2022, expires 22 June 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 24
3 June 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8390615
7 May 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8134859
14 February 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8088534
20 November 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8037638
28 August 2024
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7999220
26 June 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7943035
24 July 2023
ACP Periodic Oversight · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7751262
22 June 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7724559
27 December 2022
ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7616300
14 October 2022
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7577331
9 November 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7199291
5 October 2020
Administrative Inspection · ACP COI Oversight · COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7070325
12 September 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6810498
14 November 2018
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6580889
17 May 2018
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6416685
5 September 2017
ACP COI Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6260199
14 December 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6057978
8 August 2016
Administrative Inspection · ACP Periodic Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5966514
29 June 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5923865
28 August 2015
Administrative Inspection · ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5228911
14 August 2014
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4954762
3 March 2014
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4810209
17 June 2012
Initial Certification · Welding Related Inspections Qualification Testing · Administrative Inspection · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4347558
11 June 2012
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4398451
Deficiency record · 21
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 February 2025
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship, and protection of the environment. Marine Inspector found 134 overdue maintenance items to include critical items such as: Water tight doors, Water mist system, fire dampers, emergency generator load test, fire detection system and critical spares review. 74 SOLAS (2020) IX/2.1 ISM Code 7
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 February 2025
Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that 1) appropriate corrective actions are taken when required and 2) inspections are held at required intervals. Master did not make appropriate notifications to Flag State and ABS prior to replacing the rescue boat engine with a non-approved type engine. Furthermore, the non approved engine was not equipped
the safety kill lanyard, prop guard, and throttle was
held together with duct tape. Additionally, vessel
conducted FMEA trails offshore in this condition. Recommend an additional SMS external verification of the vessels safety management system. 74 SOLAS (2020) IX/5 ISM Code 10
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 February 2025
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship, and protection of the environment. Marine Inspector identified falsified monthly maintenance tasks logged in their preventive maintenance system in regards to the rescue boat davit. 74 SOLAS (2020) IX/2.1 ISM Code 7
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate us. The main fire pump is not operating as designed. Marine inspector observed the mechanical seal leaking. 74 SOLAS (2020) II/2 14.2.2.1.2
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate us. Marine Inspector identified that the A60 fire doors in the Galley were overdue for their annual servicing. 74 SOLAS (2020) II/2 14.2.2.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 1 February 2025
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Marine inspectors found the search light, flash light and spare batteries inoperable. 74 SOLAS (2020) III/20
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 February 2025
Resolved
Performance of crew members assigned fire-fighting duties shall be periodically evaluated by conducting on-board training and drills to identify areas in need of improvement, to ensure competency in fire-fighting skills is maintained, and to ensure the operational readiness of the fire-fighting organization. While conducing drills, Marine Inspector identified communication failures from the U.S. Master to the Brazilian Chief Mate due to a language barrier. Master is unable to commutate to the crew without a translator, resulting in poor drill performance and training. 74 SOLAS (2020) II/2 15.2.2.2.3
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 February 2025
Resolved
Each operation and failure required to be recorded in the oil record book (ORB) shall be completed in accordance with the convention. During review of the ORB, Marine Inspector identified inconsistency regarding log entries to include sulfur content, tagged out OWS, and using "white out" for corrections. MARPOL Annex I/17
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2025
Resolved
Lifebuoys - Life buoy lights were found with unapproved batteries. 74 SOLAS (2020) III/7.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate
use. MI found fire main isolation valves inoperable. 74 SOLAS (2020) II/2 14.2.2.1.2
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2022
Resolved
F?ire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessels E-Gen room's fire suppression relay box has a damaged toggle switch that prevents system from operating properly.
Repair and prove proper operation to the satisfaction of the attending RO.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 November 2021
Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operable locally from each side of the bulkhead. Observed leaks on hydraulic actuators for the FWD and AFT sliding watertight doors. 74 SOLAS 2020 II-1/13-1.2 50a
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 November 2021
Resolved
Unless expressly provided otherwise, launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided for all survival craft. Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent over stressing the falls or davit, unless the motor is designed to prevent such over stressing.Observed limit switch on davit no operating as designed. 74 SOLAS III/16.1
LSA Code 6.1.2.7 10c
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 November 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Water mist system is not working in automatic mode preventing the the fuel purifier sections from activating by smoke and heat detection system.74 SOLAS 2020 II-2/14.2.1.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020
Resolved
Means shall be provided to control leaks of flammable liquids. MI noted wasted & chafed fuel oil lines on the forward generator prime mover and aft generator prime mover. MI also noted excessive oil leak on port main engine by propulsion shaft connection to the clutch. Master shall provide evidence of effective repairs to the RO before departure.
74SOLAS(2014)II-2/4.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 October 2020
Resolved
All external openings leadings to watertight compartments below the waterline must be watertight. MI noted deficient gasket on bow thruster watertight hatch. Master shall provide evidence of repairs to RO within 14 days.
74SOLAS(2014)II-1/15-1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020
Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high pressure line failure. SOLAS tape or covers were not provided at the aft high pressure fuel line connections on both the starboard and port main diesel engines. Master shall provide evidence of protection for high pressure fuel lines to RO within 14 days.
74SOLAS(2014)II-2/2.2.5.2
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 5 October 2020
Resolved
Ships over 400 ITC GT shall be fitted with oil filtering equipment meeting the requirements of the organization. Vessel is fitted with two (02) MEPC.107(49) oil water separators (OWS) that have an arrangement for overboard discharge that allows a connection after the oil content meter (OCM) controlled overboard discharge valve. This connection is not fitted with a check valve and could allow for a direct connection to the overboard discharge from the OWS without passing through the OCM first. Master shall install check valves at the test connections after the OCM overboard discharge valve to the satisfaction of the RO within 30 days.
73/78MARPOL(2017)I/14.6
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2020
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Wire connections with exposed wire nuts outside of a junction box were made below the diesel filters for the port generator and were immersed in liquid within the containment underneath the filters. Chief Engineer corrected during inspection and removed the liquid from the containment.
74SOLAS(2014)II-1/40.1.1.3
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 October 2020
Resolved
Each liferaft shall be stowed with a float-free arrangement so that each floats free and, if inflatable, inflates automatically when the sink ships. The top liferafts on each side of the vessel were configured improperly with the hydrostatic release units for float-free release. Master corrected on the spot.
74SOLAS(2014)III/13.4.2
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 17 June 2012
Resolved
Conduct audit for issuance of Safety Management Certificate. Complete during period of DP testing in Fourchon, LA prior to employment of vessel.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.