Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
Inspection history · 19
3 June 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8390615
7 May 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8134859
14 February 2025
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8088534
20 November 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8037638
28 August 2024
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7999220
26 June 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7943035
24 July 2023
ACP Periodic Oversight · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7751262
22 June 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7724559
27 December 2022
ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7616300
14 October 2022
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7577331
9 November 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7199291
5 October 2020
Administrative Inspection · ACP COI Oversight · COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7070325
12 September 2019
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6810498
14 November 2018
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6580889
17 May 2018
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6416685
5 September 2017
ACP COI Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6260199
14 December 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6057978
8 August 2016
Administrative Inspection · ACP Periodic Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5966514
29 June 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5923865
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 February 2025
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship, and protection of the environment. Marine Inspector found 134 overdue maintenance items to include critical items such as: Water tight doors, Water mist system, fire dampers, emergency generator load test, fire detection system and critical spares review. 74 SOLAS (2020) IX/2.1 ISM Code 7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 March 2025
Resolution: ABS accepted as a condition of class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 1 February 2025
Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that 1) appropriate corrective actions are taken when required and 2) inspections are held at required intervals. Master did not make appropriate notifications to Flag State and ABS prior to replacing the rescue boat engine with a non-approved type engine. Furthermore, the non approved engine was not equipped
the safety kill lanyard, prop guard, and throttle was
held together with duct tape. Additionally, vessel
conducted FMEA trails offshore in this condition. Recommend an additional SMS external verification of the vessels safety management system. 74 SOLAS (2020) IX/5 ISM Code 10
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 March 2025
Resolution: ABS accepted as a condition of class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 February 2025
Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of personnel, ship, and protection of the environment. Marine Inspector identified falsified monthly maintenance tasks logged in their preventive maintenance system in regards to the rescue boat davit. 74 SOLAS (2020) IX/2.1 ISM Code 7
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 March 2025
Resolution: ABS accepted as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate us. The main fire pump is not operating as designed. Marine inspector observed the mechanical seal leaking. 74 SOLAS (2020) II/2 14.2.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2025
Resolution: ABS accepted as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate us. Marine Inspector identified that the A60 fire doors in the Galley were overdue for their annual servicing. 74 SOLAS (2020) II/2 14.2.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2025
Resolution: ABS accepted as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 1 February 2025
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Marine inspectors found the search light, flash light and spare batteries inoperable. 74 SOLAS (2020) III/20
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2025
Resolution: ABS accepted as a condition of class.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 1 February 2025
Resolved
Performance of crew members assigned fire-fighting duties shall be periodically evaluated by conducting on-board training and drills to identify areas in need of improvement, to ensure competency in fire-fighting skills is maintained, and to ensure the operational readiness of the fire-fighting organization. While conducing drills, Marine Inspector identified communication failures from the U.S. Master to the Brazilian Chief Mate due to a language barrier. Master is unable to commutate to the crew without a translator, resulting in poor drill performance and training. 74 SOLAS (2020) II/2 15.2.2.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2025
Resolution: ABS accepted as a condition of class.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 1 February 2025
Resolved
Each operation and failure required to be recorded in the oil record book (ORB) shall be completed in accordance with the convention. During review of the ORB, Marine Inspector identified inconsistency regarding log entries to include sulfur content, tagged out OWS, and using "white out" for corrections. MARPOL Annex I/17
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 February 2025
Resolution: ABS accepted as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2025
Resolved
Lifebuoys - Life buoy lights were found with unapproved batteries. 74 SOLAS (2020) III/7.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 February 2025
Resolution: Prior to departing vessel the unapproved batteries were replaced with approved batteries.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 February 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate
use. MI found fire main isolation valves inoperable. 74 SOLAS (2020) II/2 14.2.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 February 2025
Resolution: Prior to departing vessel a satisfactory test was witnessed of the isolation valves.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 November 2022
Resolved
F?ire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessels E-Gen room's fire suppression relay box has a damaged toggle switch that prevents system from operating properly.
Repair and prove proper operation to the satisfaction of the attending RO.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2022
Resolved 20 November 2022
Resolution: Damaged toggle switch to the relay box for the EDG room fire suppression system was repaired, tested and found operational.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 November 2021
Resolved
Doors provided to ensure the watertight integrity of internal openings which are used while at sea are to be sliding watertight doors capable of being remotely closed from the bridge and are also to be operable locally from each side of the bulkhead. Observed leaks on hydraulic actuators for the FWD and AFT sliding watertight doors. 74 SOLAS 2020 II-1/13-1.2 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Resolution: Class Surveyor [name withheld] accepted deficiency as a condition of class.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 10 November 2021
Resolved
Unless expressly provided otherwise, launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided for all survival craft. Where davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent over stressing the falls or davit, unless the motor is designed to prevent such over stressing.Observed limit switch on davit no operating as designed. 74 SOLAS III/16.1
LSA Code 6.1.2.7 10c
Action required: 10 - Deficiency Rectified
Resolved 10 November 2021
Resolution: Limit switch was adjusted by vessel personnel, system tested with satisfactory results.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 November 2021
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Water mist system is not working in automatic mode preventing the the fuel purifier sections from activating by smoke and heat detection system.74 SOLAS 2020 II-2/14.2.1.2
Action required: 10 - Deficiency Rectified
Resolved 10 November 2021
Resolution: Vessel personnel found two heat detectors were switched from the housing preventing the system from operating as designed. detectors were switched back their proper location, system was tested with satisfactory results.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020
Resolved
Means shall be provided to control leaks of flammable liquids. MI noted wasted & chafed fuel oil lines on the forward generator prime mover and aft generator prime mover. MI also noted excessive oil leak on port main engine by propulsion shaft connection to the clutch. Master shall provide evidence of effective repairs to the RO before departure.
74SOLAS(2014)II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 6 October 2020
Resolved 6 October 2020
Resolution: Vsl added chaffing material
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 October 2020
Resolved
All external openings leadings to watertight compartments below the waterline must be watertight. MI noted deficient gasket on bow thruster watertight hatch. Master shall provide evidence of repairs to RO within 14 days.
74SOLAS(2014)II-1/15-1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Vsl replaced gasket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 October 2020
Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high pressure line failure. SOLAS tape or covers were not provided at the aft high pressure fuel line connections on both the starboard and port main diesel engines. Master shall provide evidence of protection for high pressure fuel lines to RO within 14 days.
74SOLAS(2014)II-2/2.2.5.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 6 October 2020
Resolution: Vsl contractor added SOLAS tape to all fittings
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 5 October 2020
Resolved
Ships over 400 ITC GT shall be fitted with oil filtering equipment meeting the requirements of the organization. Vessel is fitted with two (02) MEPC.107(49) oil water separators (OWS) that have an arrangement for overboard discharge that allows a connection after the oil content meter (OCM) controlled overboard discharge valve. This connection is not fitted with a check valve and could allow for a direct connection to the overboard discharge from the OWS without passing through the OCM first. Master shall install check valves at the test connections after the OCM overboard discharge valve to the satisfaction of the RO within 30 days.
73/78MARPOL(2017)I/14.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2020
Resolved 6 October 2020
Resolution: Vsl added check valve on line leading to sampling port
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 October 2020
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Wire connections with exposed wire nuts outside of a junction box were made below the diesel filters for the port generator and were immersed in liquid within the containment underneath the filters. Chief Engineer corrected during inspection and removed the liquid from the containment.
74SOLAS(2014)II-1/40.1.1.3
Action required: 10 - Deficiency Rectified
Due 5 October 2020
Resolved 5 October 2020
Resolution: Chief Engineer corrected during inspection and removed the liquid from the containment.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 October 2020
Resolved
Each liferaft shall be stowed with a float-free arrangement so that each floats free and, if inflatable, inflates automatically when the sink ships. The top liferafts on each side of the vessel were configured improperly with the hydrostatic release units for float-free release. Master corrected on the spot.
74SOLAS(2014)III/13.4.2
Action required: 10 - Deficiency Rectified
Due 5 October 2020
Resolved 5 October 2020
Resolution: The crew removed and properly re installed the hydrostatic release mechanism.