Records from 2015 to 2026. Most recent: inspection, 17 July 2026.
Inspection history · 50
17 July 2026
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8448365
11 May 2026
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8370842
1 May 2026
COC-CVE Annual · PSC A
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8354983
18 April 2026
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8351816
6 April 2026
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8345060
9 May 2025
PSC A · COC-CVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8130510
19 February 2025
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8081559
28 April 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7900032
22 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7841734
30 October 2023
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7814199
2 April 2023
COC-CVE Quarterly · PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7657801
20 December 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611248
2 November 2022
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7588197
27 October 2022
PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7580228
27 April 2022
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439129
8 November 2021
PSC A · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7345434
3 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dpw) · USCG Southeast District (CGD-SE) · Activity 6935060
17 October 2019
PII Safety Exam · Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6836642
21 August 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6791698
13 August 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6786413
20 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758329
13 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6751863
3 May 2019
MARPOL Annex I Examination · ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination · PII Safety Exam · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6676279
18 March 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6644573
14 March 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6650459
17 January 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613154
6 December 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6595028
30 November 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6593519
5 November 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6574963
2 November 2018
COC-CVE Annual
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6573179
31 May 2018
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6429859
31 May 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6443831
17 April 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6397493
3 April 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384493
19 February 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6384520
3 November 2017
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6300133
6 July 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6199530
4 May 2017
ISPS II Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6139249
26 February 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6095364
11 January 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087306
1 November 2016
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6033011
11 October 2016
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6020115
22 September 2016
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6007472
30 April 2016
ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5867755
23 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5841928
9 February 2016
Damage Survey · In-Service Inspection · STCW 95 Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5812143
8 February 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5811650
7 February 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5813486
6 January 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5792067
3 November 2015
ISPS II Exam · Ballast Water Examination · COC-CVE Initial
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5756268
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 1 May 2026
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. Except as otherwise stated, the normal equipment of every life boat shall consist of a food ration totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate; kept in airtight packaging and be stored in a watertight container. PSCO observed 143 compromised rations, distributed about port and starboard side lifeboats. This deficiency must be rectified to clear remark regarding restriction of lifeboat operation on Certificate of Compliance issued 1 May 2026.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2026
Resolved 11 May 2026
Resolution: Attended vessel in company of LR surveyor. Confirmed new food rations had been placed onboard. LR issued full-term PSSC with full POB number. Cleared this deficiency and restriction on COC accordingly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 May 2025
Resolved
The purpose of this regulation is to provide means of escape
so that persons on board can safely and swiftly escape to the
lifeboat and life raft embarkation deck. For this purpose, the following functional requirements shall be met: escape
routes shall be maintained in a safe condition, clear of
obstacles. Trolley with stores discovered stored in the
corridor outside of AC Room 5-12, Fire Door 12-5-001,
impeding means of escape. Large tank discovered blocking
and holding open Fire Door 02-7-003, impeding means of
escape. 74 SOLAS 20 II-2/13.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Tank removed from vicinity of fire door clearing way for means of escape.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 May 2025
Resolved
The means of escape, including stairways and exits, shall be
marked by lighting or photoluminescent strip indicators
placed not more than 300 mm above the deck at all points of
the escape route, including angles and intersections. The
marking must enable passengers/crew to identify the
routes of escape and readily identify the escape exits.
Additionally, escape route signs and fire equipment
location markings shall be of photoluminescent material or marked by lighting. Large planter stowed in Deck 15 port side
elevator lobby discovered blocking low location lighting.
74 SOLAS 20 II-2/13.3.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Crew removed planter blocking the low location lighting.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2025
Resolved
The electrical power shall be sufficient to supply all those
services essential for safety and emergency. Emergency
lighting fixtures located at lifeboat #18 walkway, lifeboat #8 deck area, near spa room #11, Deck 14 port side outdoor,
and Deck 16 fwd stairwell discovered inoperable.
74 SOLAS 20 II-1/42.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Crew replaced light bulbs in all locations where emergency lighting was inoperable and tested. All Sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 May 2025
Resolved
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use.
Pre-engineered fire fighting system installed in lifeboat
tender #10 discovered to have the maintenance pin still in
place preventing intended use in case of fire.
74 SOLAS 20 II-2/14.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Maintenance pin removed from system to allow for manual activation from operating station. Coordinated review of all pre engineered fire fighting systems, on tenders, to ensure maintenance pins were removed and activation from operating station. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 May 2025
Resolved
All lifeboats shall be provided with a rudder and tiller. When a wheel or other remote steering mechanism is also provided the tiller shall be capable of controlling the rudder in case of failure of the steering mechanism. The tiller shall be permanently installed on, or linked to, the rudder stock and the tiller may be removable and securely stowed near the rudder stock. Lifeboat #16 emergency steering tiller pin was not easily removable/seized in place preventing operational test to install tiller.
74 SOLAS 20 III/34 LSA Code 4.4.7.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Crew was able to loosen the valve that was over pressured preventing the acuation of the tiller. Operational test of emergency tiller conducted. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 May 2025
Resolved
All life-saving appliances and arrangements shall comply
with the applicable requirements of the Code. The engine
shall be capable of operating for not less than 5 min after
starting from cold with the lifeboat out of the water. Port side #6 lifeboat port engine inoperable and unable to test during drill.
74 SOLAS 20 III/34 LSA Code 4.4.6.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2025
Resolved 9 May 2025
Resolution: Vessel engineer attended, enacted repair, engine retested satisfactory. All Sat.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 30 October 2023
Resolved
In ships carrying more than 36 passengers, the hull, superstructure and deckhouses shall be subdivided into main vertical zones by "A-60" class divisions. Vessel is equipped with an approved alternative arrangement in the main promenade. Vessel has rolling shutters in place of A-60 bulkhead for main vertical zone. During testing of roller shutters, 1 of 2 shutters between MVZ 5 & 6 failed to close.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2023
Resolved 30 October 2023
Resolution: Crew was able to repair rolling shutter while team was on board. Team witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 November 2021
Resolved
Escape routes shall be maintained in a clear condition, safe of obstacles. Escape route backstage of theatre (near FD-03-2-001) was onstructed by theatre equipment.
SOLAS 20 II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 17 November 2021
Resolution: Vessels crew moved obstruction to safe area.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 November 2021
Resolved
Muster/embarkation stations shall be adequately illuminated by lighting supplied by the emergency source of electrical power. Emergency lighting near lifeboat 11 was inoperable.
Action required: 10 - Deficiency Rectified
Resolved 17 November 2021
Fire Fighting › Structural - A Class Divisions › Aux Spaces (little/no fire risk)
Issued 1 November 2016
Resolved
In addition to complying with the provisions for fire integrity of bulkheads of passenger ships, the minimum fire integrity of all bulkheads and decks shall be as perscribed in table 9.1. The dumbwator located in the pool bar pantry is required to meet A-0 boundary.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 10 November 2016
Resolution: Class was in attendance and issued condition of class for def.