MIDAS

MIDAS is a 1990 freight ship. The Coast Guard has recorded 26 inspections since 2016, most recently in July 2026, along with 19 deficiencies and 6 operational controls.

Records from 2016 to 2026. Most recent: inspection, 20 July 2026.

Built
1990
Last inspected
20 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 July 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9002659
1174718
Flag
FINLAND
Maury page id
psix-1174718

Documentation record

Tonnage as PSIX records it5873 - Convention (Subpart B), Gross Ton
1762 - Convention (Subpart B), Net Ton
4491 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

20 July 2026 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8441124
12 January 2026 PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8293631
6 January 2025 PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8057583
30 December 2024 PSC A
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8050734
25 March 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7418523
10 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7409656
10 March 2022 Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7409744
6 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7406576
12 January 2022 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7379011
1 December 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7358311
1 December 2021 COE-Dockside · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7359558
9 April 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7170990
24 March 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7161960
18 November 2020 Deficiency Check · PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7096680
8 April 2019 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6655698
2 October 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6551156
16 April 2018 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6390400
2 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6381088
29 September 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6276530
19 June 2017 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6180118
12 April 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6122789
6 March 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6098473
5 September 2016 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5988585
24 March 2016 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5839794
29 February 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5823138
29 February 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5824071

Deficiency record · 19

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 30 December 2024 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. THE TECHNICAL AND/OR OPERATIONAL NATURE OF DEFICIENCIES 02, 03, 04, 05, 06 & 07 PROVIDE EVIDENCE OF A SERIOUS FAILURE OF THE IMPLEMENTATION OF THE ISM CODE. A THIRD PARTY SAFETY MANAGEMENT SYSTEM AUDIT MUST BE CONDUCTED AND A REPORT, SATISFACTORY TO THE OCMI, MUST BE SUBMITTED PRIOR TO CLEARANCE OF THIS DEFICIENCY. 74SOLAS(2020)IX/5 ISM CODE 10.1 30ABC
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. DEFICIENCY RECTIFIED.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 30 December 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. DEFICIENCY RECTIFIED.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 30 December 2024 Resolved
ANY FAILURE OF THE OIL FILTERING EQUIPMENT SHALL BE RECORDED IN THE OIL RECORD BOOK PART I. VESSEL PERSONNEL FAILED TO RECORD THE FAILURE OF THE OILY WATER SEPERATOR INTO THE OIL RECORD BOOK. MARPOL ANNEX I/17.5 17AC
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. DEFICIENCY RECTIFIED.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 30 December 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. DEFICIENCY RECTIFIED.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 December 2024 Resolved
MUSTER AND EMBARKATION STATIONS SHALL BE ADEQUATELY ILLUMINATED BY LIGHTING SUPPLIED FROM THE EMERGENCY SOURCE OF ELECTRICAL POWER REQUIRED BY REGULATION 11.1/42 OR 1l.1/43, AS APPROPRIATE. VESSEL CREW WAS UNABLE TO ACTIVATE EMERGENCY LIGHTING ADJACENT TO THE RESCUE BOAT AND LIFEBOAT EMBARKATION AREA. 74SOLAS(1997)III/11.5 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. EMERGENCY LIGHTING REPLACED BY VESSEL CREW DEFICIENCY RECTIFIED.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 December 2024 Resolved
ANY REQUIRED FIRE DETECTION AND FIRE ALARM SYSTEM BE CAPABLE OF IMMEDIATE OPERATION AT ALL TIMES. THE SMOKE DETECTOR IN THE PASSAGEWAY NEAR THE GALLEY CONTAINED A COVER OVER THE SMOKE DETECTOR. 74SOLAS(97) II-2/12
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2024
Resolution: 3rd officer removed the cover upon finding.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 December 2024 Resolved
FIRE DOORS IN A MAIN VERTICAL zONE BULKHEADS AND STAIRWAY ENCLOSURES SHALL SATISFY THE FOLLOWING REQUIREMENTS: THE DOORS SHALL BE SELF-¬CLOSING AND BE CAPABLE OF CLOSING AGAINST AN ANGLE OF INCLINATION OF UP TO 3.5° OPPOS ING CLOSURE AND SHALL HAVE AN APPROXIMATE UNIFORM RATE OF CLOSURE OF NO MORE THAN 40s AND NO LESS THAN 10S WITH THE SHIP IN UPRIGHT POSITION. PSCO OBSERVED MULTIPLE FIRE DOORS IN THE CARGO AREA UNCAPABLE OF SELF CLOSING. 74SOLAS(1997)II-2/4.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2025
Resolution: A REPORT SATISFACTORY TO THE OCMI AND A 3RD PARTY AUDIT HAS BEEN SUBMITTED, RECEIVED AND REVIEWED BY SECTOR SAN JUAN. FIRE DOORS ADJUSTED BY CREW AND FOUND TO FULLY SECURE. DEFICIENCY RECTIFIED.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 December 2021 Resolved
All cargos, other than solid and liquid bulk cargos, cargo unit and cargo transport units shall be loaded, stowed, and secured throughout the voyage in accordance with the cargo securing manual approved by the administration. Cargo Securing Manual requires 2 tie down points on each side of wheeled cargo; lanes on main roro deck allow for this arrangement with 5 vehicles loaded athwartships. Current loading arrangement exceeds availability of approved tie down points and does not allow any vehicles to be properly secured. 74 SOLAS(97) Ch. VI Reg. 5.6. 17c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2021
Resolution: 10c. Cargo was unloaded and reloaded in accordance with Cargo Securing Manual in presence of PSCOs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 December 2021 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Multiple doors identified to be self-closing on "A" boundaries were observed to be secured by unapproved means in the open position. 74 SOLAS(97). Ch. II-2 Reg. 47.2. 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 12 January 2022
Resolution: Class: Self-closing doors iwo "A" class divisions were inspected and found with hold-back hooks removed and in closed position. USCG: Verified no hold-back hooks on self closing doors.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 1 December 2021 Resolved
In all ships general arrangements plan shall be permanently exhibited for the guidance of the ships officers, showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions. Multiple doors identified as self-closing are not equipped with a self-closing mechanism. 74 SOLAS(97) Ch. II-2 Reg. 20.1. 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 12 January 2022
Resolution: Class: Self-closing mechanisms found installed on doors identified as self-closing iwo "A" class divisions, doors were inspected and found in closed position. USCGG: Verified each self closing door now had an installed mechanism.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 1 December 2021 Resolved
The company should establish procedures, plans and instructions, including checklists as appropriate for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel. Ship SMS requires that cargo be secured IAW cargo securing manual which requires that adequate tie-down points be available and that spacing allows for securing of cargo according to master's discretion. CSM also requires monitoring of securing equipment when required. Loading arrangements discovered by PSCOs did not comply with approved plan. 74 SOLAS(20 cons.) Ch. IX/3.1 ISM Code Reg. 7. 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 12 January 2022
Resolution: Class: defered to flag saying it was outside their scope. Flag: Could not find that the vessel operations were in conflict with the Cargo Securing Manual or the CSS Code. USCG: Verified that the vessel was currently operating in compliance.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 9 April 2021 Resolved
The international load line certificate (ILLC) shall not be issued to the ship until the officer or surveyor acting under the provisions of article 13 of the present convention has certified that the marks are correctly and permanently indicated on the ships sides. the load line was observed on the ships side did not match the certificate issues to the vessel. ICLL66/88 Annex 1 Reg 9.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2021
Resolved 26 April 2021
Resolution: the load line was corrected and a new international load line certificate was issued to the vessel
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 25 March 2021 Resolved
All cargoes...shall be loaded, stowed and secured throughout the voyage in accordance with the cargo securing manual approved by the administration. Vessel is currently transporting cars as cargo, manual makes no reference to cars, nor does it have instructions on how to secure them. 74 SOLAS (14 CONS) VI/Reg 5.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: Received class report attesting to the cargo securing manual currently onboard and providing additional guidance to deficiency.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 18 November 2020 Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of design approved by the Administration...the Administration shall have regard to the specification recommended by the Organization. Bilge monitoring display screen was damaged and was only displaying partial areas of the screen as required by MEPC.107(49)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2020
Resolved 10 December 2020
Resolution: Monitor was replaced and vessel sent in tech and class report.
Communications › Visual Communication › Signalling Lamp
Issued 2 April 2018 Resolved
ALL SHIPS OVER 150GT AND UPWARDS SHALL BE FITTED WITH A DAYLIGHT SIGNALING LAMP TO COMMUNICATE BY LIGHTDURING DAY AND NIGHT USING AN ENERGY SOURCE OF ELECTRICAL POWER NOT SOLELY DEPENDENT UPON THE SHIPS POWER SUPPLY. THE VESSEL DID NOT HAVE AN INDEPENDENT SOURCE OF POWER AND RELIED SOLELY ON THE SHIPS POWER SUPPLY.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2018
Resolved 16 April 2018
Resolution: Received proper documentation attesting to the acquisition of an independent source of energy for ship's Daylight Signaling Lamp.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 6 March 2017 Resolved
cargo, cargo units and cargo transit units shall be loaded, stowed and secured throughtout the voyage in accordance with the cargo securing manual approved by the administration. the cargo securing manual shall be drawn up to a standard at least equivalent to the guidelines developed by the Administration. the cargo securing manual is only available in Finnish and not English, Spanish or French.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 27 March 2017
Resolution: Received Class report along with stamped cover page of English copy of the ships Cargo Securing Manual.
Navigation › Piloting/Steering › Gyro Compass
Issued 29 February 2016 Resolved
During a voyage any equipment required by 33CFR164.53(b) stops operating properly, the person directing the movement of the vessel may continue to the next port of call subject to direction of COTP. PSCO found gyrocompass was not working and no letter of deviation request was submitted to USCG prior vessel's arrival. 33CFR164.53 (a) & (b).
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 March 2016
Resolution: Recieved Tech report as per required by deficiency.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 29 February 2016 Resolved
All waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. PSCO found plastic combustible waste receptacles stored in the aft mooring deck. 74SOLAS(97)II-2/18.5.
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 28 March 2016
Resolution: Received purchase report from vessel operator for non combustable waste receptacles.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 February 2016 Resolved
A second source of energy shall be provided for an additional three starts within 30 minutes. The vessel's secondary means of starting, which consists of film & matches failed to provide a start within 30 ins timeframe. C/E says that they test it every week but new C/E seems unfamiliar with practice. 74SOLAS81AmendmentsII-1/44.2.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 February 2016
Resolved 29 February 2016
Resolution: Second means of starting emergency generator was satisfactorily demonstrated.