MAURY USCG vessel records
← All vessels

INDUSTRIAL OLIVIA

INDUSTRIAL OLIVIA is a 2011 freight ship. The Coast Guard has recorded 16 inspections since 2018, most recently in August 2026, along with 23 deficiencies and 1 operational control.

Records from 2018 to 2026. Most recent: inspection, 5 August 2026.

Built
2011
Last inspected
5 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2026
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9467005
1174933
Flag
LIBERIA
Maury page id
psix-1174933

Documentation record

Tonnage as PSIX records it9611 - Convention (Subpart B), Gross Ton
4260 - Convention (Subpart B), Net Ton
12672 - Dead Weight, Metric Ton
17972 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

5 August 2026 Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8455717
24 December 2025 Deficiency Check · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8287049
7 October 2025 Appeal
Administrative · Commandant (CG-CVC) · Activity 8257016
4 September 2025 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8225427
3 September 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8226010
26 August 2025 Deficiency Check · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8212598
28 July 2025 PSC B · ISM Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8192974
24 July 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8193471
23 July 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8192905
6 July 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7950453
5 July 2023 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7734302
17 May 2022 PSC B
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7449861
13 May 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7449948
19 April 2021 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7178368
7 August 2020 PSC B
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7020961
4 June 2018 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6435244

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 26 August 2025 Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED IN THE FORWARD STARBOARD ENGINE ROOM LOWER DECK TRANSVERSE FRAME RAIL #34 HAD AN INSET FROM THE OUTSIDE OF THE ENGINE ROOM SHOWING DAMAGE ON MULTIPLE FRAME RAILS BEHIND. 74SOLAS(24) I /11(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2025
Resolution: class conducted survey and affected areas where repaired,inspected and found in within acceptable limit
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 August 2025 Resolved
SAFE AND EFFICIENT MEANS OF ASCERTAINING THE AMOUNT OF OIL FUEL CONTAINED IN ANY OIL FUEL TANK SHALL BE PROVIDED. PSCO OBSERVED MDO TANK #2 INSTALLED GAUGE WAS INOPERABLE. CREW REPLACED WITH RUBBER HOSE. 74SOLAS(24) II-2 / 4.2.2.3.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2025
Resolution: crew replaced with rubber hose, photo provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 August 2025 Resolved
NOT LESS THAN... NOT LESS THAN TWO OF THESE SHALL ALSO BE PROVIDED WITH LIFE BUOY SELF-ACTIVATING SMOKE SIGNALS COMPLYING WITH THE REQUIREMENTS OF PARAGRAPH 2.1.3 OF THE CODE AND BE CAPABLE OF QUICK RELEASE FROM THE NAVIGATION BRIDGE; LIFE BUOYS WITH LIGHTS AND THOSE WITH LIGHTS AND SMOKE SIGNALS SHALL BE EQUALLY DISTRIBUTED ON BOTH SIDES OF THE SHIP... PSCO OBSERVED NO EXPIRATION DATE ON BUOY PYROTECHNICS. CREW WAS UNABLE TO PROVIDE ANY DOCUMENTATION SHOWING VALIDITY OF BUOY PYROTECHNICS. DOCUMENTATION PROVIDED BY CREW WAS FOR A DIFFERENT MODEL THAN WHAT WAS ON BOARD THE SHIP. 74SOLAS(24) III/ 7.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2025
Resolution: vessel provided the delivery note showing purchase of smoke signal/life buoy
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 August 2025 Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. PSCO OBSERVED MULTIPLE GAUGES ON #2 AND #3 GENERATORS THAT WERE INOPERABLE OR READING INCORRECT INFORMATION. 74SOLAS(04) II-1/31.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 December 2025
Resolution: Def rectified by [name withheld] documents tab.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 26 August 2025 Resolved
THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF A VESSEL SUBJECT TO THIS SUBPART MUST SUBMIT A BALLAST WATER REPORT TO THE NATIONAL BALLAST INFORMATION CLEARINGHOUSE (NBIC)... FOR ANY VESSEL THAT IS EQUIPPED WITH BALLAST WATER TANKS AND BOUND FOR PORTS OR PLACES IN THE UNITED STATES AND NOT ADDRESSED IN PARAGRAPHS (b)(1) AND (2) OF THE SECTION: SUBMIT THE BALLAST WATER REPORT NO LATER THAN 6 HOURS AFTER ARRIVAL AT THE PORT OR PLACE OF DESTINATION, OR PRIOR TO DEPARTURE FROM THAT PORT OR PLACE OF DESTINATION, WHICHEVER IS EARLIER. PSCO OBSERVED THAT NO BALLAST WATER REPORT WAS SUBMITTED WITHIN 6 HOURS OF ARRIVAL ON 23AUG2025.
Action required: 10 - Deficiency Rectified
Resolved 26 August 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 8 August 2025 Resolved
The safety management system should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. Vessel could not provide objective evidence that corrective action reports were sent for non-conformities/deficiencies issued by DNV on 23JUN2025 in accordance with established regulatory and flag Administration procedures.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Def rectified by [name withheld] documents tab.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 August 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Master could not provided objective evidence that required maintenance, testing, and inspections required by SOLAS 74 (20) II-2/14.2.2 have been carried out in accordance with applicable regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Def rectified by [name withheld] documents tab.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 August 2025 Resolved
The company should ensure that inspections are held at appropriate intervals and records of these activities are maintained. Master did not provide the necessary objective evidence to confirm conformance with established maintenance requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Def rectified by [name withheld] documents tab.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 August 2025 Resolved
The company should establish procedures for implementation of corrective action including measures intended to prevent recurrence. During expanded ISM examination, the master provided a sampling of Non-Conformance Reports, Form SAF/03, that did not include measures to prevent recurrence. Master did not provide the necessary objective evidence to confirm conformance with established requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 8 August 2025 Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. Master did not provide the necessary objective evidence to confirm conformance with established maintenance requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 8 August 2025 Resolved
The company should ensure obsolete documents are promptly removed from its safety management system. PSCO observe outdated ISM & SOLAS references depicted in company Safety Management System's Procedural Manuals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 8 August 2025 Resolved
The company should carry out internal safety audits on board and ashore at intervals not exceeding twelve months to verify whether safety and pollution prevention activities comply with the safety management system. Last internal audit was conduct on June 27, 2024. Master was unable to provide objective evidence documenting a more recent internal audit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 8 August 2025 Resolved
The company should ensure changes to documents are reviewed and approved by authorized personnel. PSCO observed and received numerous revisions to established company Safety Management System's Procedure Manuals in the draft format.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 8 August 2025 Resolved
The company should ensure the master is fully conversant with the company's safety management system. During the expanded ISM examination, the master was unable to demonstrate familiarity with SMS and SMS Procedural Manuals or provide requested documentation to confirm conformance with established procedures during on board interviews conducted by the attending PSCO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 July 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the deficiencies of a technical and/or operational nature identified below which individually or collectively provides objective evidence of a serious failure, or lack of effectiveness of the ISM Code, an external audit shall be conducted by the Flag Administration before the vessel will be released from its detention to determine whether the vessel is operating in compliance with the ISM Code. A copy of the completed external audit shall be provided for USCG review prior to departure from the port of Mobile. Cite: 74SOLAS(20)IX/3.1 // ISM Code Part A 10.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 8 August 2025
Resolution: PSCO obtained a copy of the ISM audit from Flag.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 July 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed multiple inoperable water mist sprinkler heads without sufficient fire-extinguishing coverage for main diesel generators and oil purifier space. Cite: 74SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: PSCO observed satifactory test of Hyper-Mist system.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 July 2025 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed maintenance, testing and inspections of water mist system was not carried out in alignment with guidelines developed by the Organization. Cite: 74SOLAS(20) II-2/14.2.2.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Received tech report attesting to testing of Hyper-Mist.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 July 2025 Resolved
Systems and equipment used to meet the requirements of this regulation shall conform to performance standards and functional requirements not inferior to those adopted by the Organization. PSCO observed that LRIT conformance test report was expired. Cite: 74SOLAS(20) V/19-1.6
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2025
Resolution: Vessel submitted a valid LRIT conformance test report - see docs.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 28 July 2025 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. PSCO observed crew unable to start emergency generating set using secondary source of power. Cite: 74SOLAS(09) II-1/44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2025
Resolution: PSCO observed satisfactory test of emergency generator.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 July 2025 Resolved
Where a fixed gas fire-extinguishing system is used, openings which may admit air to, or allow gas to escape from, a protected space shall be capable of being closed from outside the protected space. PSCO observed all channel drains on cargo holds incapable of being closed due to design. Cite: 74SOLAS(09) II-2/10.4.2
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 December 2025
Resolution: Objective evidence provided to PSCO.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 July 2025 Resolved
The maintenance plan shall include at least the following fire protection systems and fire-fighting systems and appliances, where installed: fixed fire-extinguishing systems and other fire-extinguishing appliances. PSCO observed maintenance plan did not include required procedures for quarterly or annual testing and inspections of water mist systems. Cite: 74SOLAS(20) II-2/14.2.2.3
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 December 2025
Resolution: Objective evidence provided from RO.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 28 July 2025 Resolved
The safety management system should ensure compliance with mandatory rules and regulations and that applicable codes, guidelines and standards recommended by the Organization, Administrations, classification societies and maritime industry organizations are taken into account. During expanded ISM examination, the master was unable to provide objective evidence that applicable Liberia Maritime Authority Marine Notices have been implemented in established SMS and SMS Procedural Manuals.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2025
Resolved 24 December 2025
Resolution: Objective evidence provided from Admin.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 May 2022 Resolved
SOLAS 74 (2020) III/13.4.2,LSA 4.1.6.1: The Life raft painter system shall provide a connection between the ship and the life raft, and shall be so arranged as to ensure that the life raft, when released, and in the case of an inflatable inflated is not dragged under by the sinking ship. The painter on the port side life raft was not secured to the break-away links. Deficiency corrected on spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 May 2022
Resolved 17 May 2022
Resolution: Ship's Crew corrected on Spot, Coast Guard Examiner verified that the Sea Painter was secured properly to the Hydrostatic release system.

Ownership record