Records from 2016 to 2024. Most recent: inspection, 7 October 2024.
Inspection history · 20
7 October 2024
COI Inspection · In-Service Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8015349
7 August 2024
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7977420
13 November 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7824290
21 October 2022
Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7581744
3 October 2022
Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7570971
9 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7557116
5 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7375835
16 July 2021
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7258467
22 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7082603
31 October 2019
MARPOL Annex VI Survey · Deficiency Check · Drydock Exam · COI Inspection · Administrative Inspection · MTSA/ISPS Verification · Internal Structural Exam · Cargo Tank Internal · MARPOL Annex I Examination · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6846400
27 March 2019
MTSA/ISPS Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6650696
7 February 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6624020
16 January 2018
Administrative Inspection · Drydock Exam · MARPOL Annex VI Survey · Internal Structural Exam · Damage Survey · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6338576
12 January 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6338343
2 February 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6082189
10 November 2016
MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex IV Survey · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex VI Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6039144
4 October 2016
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6015405
16 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6002667
21 July 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5947985
5 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5847744
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2021
Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a marine inspector each time an accident occurs; Vessel sustained inset damage, approximately 5' wide, 6-8" deep, along a transverse bulkhead separating a fuel tank from a ballast tank. Angle iron, sized 4"x6", within the ballast tank shall be renewed as original. Ends of angle framing shall be renewed as original. Vessel is to transit from Port Fourchon, LA to Allied Shipyard, Golden Meadow, LA to affect repairs to sustained damage. VEssel representative is to contact the OCMI to requst attendance of a Marine Inspector to verify satisfactory completion of all repairs. Vessel is to not depart Allied Shipyard, Golden Meadow, LA to conduct commercial activities until all repairs have been completed to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2021
Resolution: All repairs were completed to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 November 2019
Resolved
CONDUCT REPAIR OF FIRE MAIN VALVES AND DEMONSTRATE USE OF INLINE INDUCTOR PRIOR TO GETTING UNDERWAY AND CARRYING PORTABLE TANKS TO COAST GUARD MARINE INSPECTOR OR ABS SURVEYOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2019
Resolved 14 November 2019
Resolution: ABS SURVEYOR VERIFIED REPAIRS COMPLETED AND THE INLINE INDUCTOR OPERATED SATISFACTORILY.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 November 2016
Resolved
Liquid mud tank valves do not have remote shutoffs. Vessel may not carry oil-based liquid mud until valve remote shutoffs are installed.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 2 February 2017
Resolution: Remote shutoffs added. Witnessed satisfactory operation.
Electrical › Electric Generation Source (service) › Switch
Issued 11 October 2016
Resolved
Prove operation of the port ENG room air intake P3-1 controller.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 October 2016
Resolved 14 November 2016
Fire Fighting › Fire Pumps › Location
Issued 21 July 2016
Resolved
Space containing emergency fire pump has direct access to category "A" machinery space. SOLAS II-2 Reg 10/2.2.3.2.2.2 Alterations to be made prior to international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Repairs witnessed by Coast Guard and ABS on 14NOV16.
Electrical › Electrical Distribution System (emergency) › Switchboard
Issued 21 July 2016
Resolved
Emergency 208/120V switchboard is not easily accessible. SOLAS II-1 Regs 43.5.1 and 45.2 Alterations to be made prior to international voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 November 2016
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 21 July 2016
Resolved
Emergency ventilation and fuel pump stops will not stop equip if damage to wiring occurs. Alterations to be made prior to operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 November 2016
Electrical › Electrical Distribution System (emergency) › Cable
Issued 21 July 2016
Resolved
Emergency power cables run through category "A" machinery space and generator space.SOLAS II-1 Reg 43.1.3 Alterations to be made prior to international voyage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 November 2016
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 July 2016
Resolved
General Arrangement/Fire Control plan must be updated. Alterations to be made prior to operation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 November 2016
Resolved 14 November 2016
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 5 April 2016
Resolved
Vessel has aluminum paint locker. All paint lockers must be constructed of steel or lined with steel. Vessel is required to remove paint locker during next drydock.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 January 2018
Resolved 25 January 2018
Resolution: Vessel removed aluminum paint locker and replaced with a steel paint locker.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 April 2016
Resolved
GMDSS shore based maintenance certificate was expired. Required vessel to provide proof of current shore based maintenance contract. 47 CFR 80.1105
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 5 April 2016
Resolution: Vessel provided valid certificate for shore based maintenance program.