Inspection history · 57
13 November 2025
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8257881
30 October 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7818023
14 September 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7791655
24 August 2020
Administrative Inspection · Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7100558
6 May 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6677698
6 May 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6802730
3 September 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6264589
29 August 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6253571
3 June 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6166397
16 December 2015
Damage Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5783900
16 December 2015
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5815791
18 November 2014
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5026623
18 November 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4756113
16 September 2013
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4738985
24 September 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4170115
2 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3922529
10 December 2010
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3908464
7 December 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3906263
25 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2915523
19 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2915257
20 July 2006
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 2747126
30 May 2006
Uninspected Other · Administrative Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2664783
5 November 2005
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2531054
24 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2008456
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957648
24 June 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833384
22 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1733831
22 January 2003
Damage Survey
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1734362
21 January 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1733802
6 March 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1493420
5 February 2002
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1486658
19 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 179834
16 December 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 13693
5 September 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 141378
20 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 135312
7 January 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 75651
3 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 39550
14 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 59969
25 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 75806
25 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2593
4 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81878
21 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 655404
18 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 177202
17 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 170755
31 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 136008
13 August 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 7817
14 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 86783
4 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 137409
18 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 176133
13 June 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81458
10 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 112662
8 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117962
1 April 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 170901
18 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 174727
11 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 90944
15 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182381
21 December 1987
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 320394
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2019
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced.
Vessel experienced loss of propulsion on both engines and ability to steer resulting from barge rigging getting caught in props.
Vessel restricted from operations until satisfactory proof of cleared steering/propulsion equipment and operation of all machinery is provided to satisfaction of CG Marine Inspector.
46 CFR 143.245(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 May 2019
Resolution: Surveyor inspected vessel on drydock after removal of obstructions and concducted satisfactory underway testing of all machinery. Vessel released.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 13 June 2006
Resolved
Ensure all fire extinguishers are properly labeled/marked.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 14 June 2006
Resolution: Removed improperly labeled fire ext (4).
Communications › Alarms/Indicators › General Alarm
Issued 13 June 2006
Resolved
Prove proper operation of visual GE indicator (red flashing light) in lower engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2006
Resolved 14 June 2006
Resolution: Installed a flashing red light in the engine room meeting the intent of the regs.
Communications › Alarms/Indicators › General Alarm
Issued 13 June 2006
Resolved
Prove proper operation of visual GE indicator (red flashing light) in the lower engine room.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2006
Documentation › Markings/Placards › Warning Signs
Issued 13 June 2006
Resolved
Install GE sign adjacent to Red Flashing Light, reading "Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station."
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 14 June 2006
Resolution: Appropriate sign placed identifying the red flashing light per the regs.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 13 June 2006
Resolved
Repair #5 stbd fuel vent gooseneck (half-dollar size hole just above end of gooseneck).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2006
Resolved 14 June 2006
Resolution: Affected temporary repair to gooseneck to the satisfaction of the marine inspector.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 13 June 2006
Resolved
Repair/replace all fuel vent fire screens.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 14 June 2006
Resolution: All fuel vent fire screens repaired/replaced.
Construction/Loadline › Hull
Issued 22 January 2003
Resolved
Proceed to [name withheld], Bollinger S/Y with temporary repair in way of starboard aft bilge slop tank. Contact Marine Safety Office New Orleans Operations Center at [phone withheld] upon arrival at Bollinger S/Y. No pumping of bilges into stbd bilge slop tank permitted. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 24 January 2003
Resolved 25 January 2003
Construction/Loadline › Hull
Issued 22 January 2003
Resolved
Make permanent repairs to starboard bilge slop tank to the satisfaction of an attending Coast Guard Marine Inspector. Contact Havey Canal Detail for inspection at [phone withheld]. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 29 January 2003
Resolved 25 January 2003
Resolution: 18" X 18" plate inserted with radius corners.
Construction/Loadline › Penetrations
Issued 22 January 2003
Resolved
Pump out and properly dispose of water in aft void under steering gear. Evaluate shaft packing for leak and make proper repair if needed. LEGACY COMPONENT DESC: Bottom Plug Packing
Condition: Unknown
Due 29 January 2003
Resolved 25 January 2003