MAURY USCG vessel records
← All vessels

VALTURCHESE

VALTURCHESE is a 2012 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in October 2025, along with 8 deficiencies and 3 operational controls.

Records from 2016 to 2025. Most recent: inspection, 7 October 2025.

Built
2012
Last inspected
7 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 October 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9541306
1190830
Flag
ITALY
Maury page id
psix-1190830

Documentation record

Tonnage as PSIX records it13613 - Convention (Subpart B), Net Ton
29814 - Convention (Subpart B), Gross Ton
50895 - Dead Weight, Metric Ton
57931 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ST. THOMAS Towing Vessel · MISLE 1104109 · 14 August 2018 · activity 6517792IN155478 Freight Barge · MISLE 1345892 · 14 August 2018 · activity 6517792IN165486 Freight Barge · MISLE 1385608 · 14 August 2018 · activity 6517792

Inspection history · 22

7 October 2025 COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8245049
20 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8214539
27 June 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8168647
27 September 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8008358
20 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7985146
27 October 2023 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7816825
12 October 2023 PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7805889
28 January 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7628428
29 October 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7585816
17 October 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7578822
28 September 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7565124
21 December 2020 Administrative Inspection · PSC B · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7114102
14 January 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6890867
16 December 2019 Ballast Water Examination · ISPS III Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6874421
3 February 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6619285
8 January 2019 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6606673
3 October 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6554795
2 October 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6552948
14 August 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6517792
13 August 2018 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6510227
5 December 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6317498
7 November 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6036491

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 September 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT CONVENTION TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT PRESENTING AN UNREASONABLE THREAT TO THE MARINE ENVIRONMENT. PSCO OBSERVED CARGO TANK STEAM HEATING SYSTEM INOPERABLE DUE TO WASTEAGE. STEAM HEATING SYSTEM SERVICES ALL CARGO TANKS AS WELL AS TANK CLEANING SYSTEM. MARPOL I/4.1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2024
Resolved 4 October 2024
Resolution: Received Class Memo and Company Comments (see documents attached this activity). Cleared deficiency, Class will be taking all further actions.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
A chemical tanker shall comply with the requirements of the international bulk chemical code. Electrical installations shall be such to minimize the risk of fire and explosion from flammable products. PSCO observed a hole in the electrical conduit pipe in a hazardous location. SOLAS20/VII/10.1 IBC 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 November 2023
Resolved 12 October 2023
Resolution: Crewmembers patched and sealed hole.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 October 2023 Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms to the standards not inferior to those acceptable to the organization. PSCO observed starboard side life buoy light in hazardous location not certified safe type.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2023
Resolved 27 October 2023
Resolution: Reviewed class report attesting to installation of certified safe light in cargo area.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 28 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2022
Resolved 28 January 2023
Resolution: SEC NOLA PSC/Arrivals Branch received a class report / proper documentation satisfying the requirement
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 28 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2022
Resolved 17 October 2022
Resolution: Received Flag state LRIT conformance test attesting to the rectification of the deficiency.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 December 2019 Resolved
The first periodical control of foam concentrates should be performed not more than 3 years after being supplied to the ship, and after that every year. PSCO observed the vessel's low expansion deck foam analysis was overdue by 27 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2020
Resolved 14 January 2020
Resolution: PSC NOLA received proper documentation satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 8 January 2019 Resolved
All lifesaving appliances and arrangements shall comply with the applicable requirements of the Code. A food ration as described in paragraph 4.1.5.1.18 totaling not less than 10,000 KJ for each person the lifeboat is permitted to accommodate. Vessel is sailing with expired lifeboat rations. 74SOLAS(14)III/34, LSA Code 4.4.8.12. 17A/C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2019
Resolution: Class report received. Vessel provided new food rations for lifeboats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 8 January 2019 Resolved
The ring lines and letter shall be painted in white or yellow on a dark background or in balck on a light ground. Vessel's load line on port and starboard side is not constrasting with the hull.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 3 February 2019
Resolution: SECTOR NEW ORLEANS PSC RECEIVED DOCUMENTATION FROM RINA SATISFYING THE REQUIREMENT.

Ownership record