MAURY USCG vessel records
← All vessels

W-SAPPHIRE

W-SAPPHIRE is a freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in June 2026, along with 15 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 12 June 2026.

Built
Not recorded
Last inspected
12 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9605645
1196372
Flag
LIBERIA
Maury page id
psix-1196372

Documentation record

Tonnage as PSIX records it43951 - Convention (Subpart B), Gross Ton
27709 - Convention (Subpart B), Net Ton
81680 - Dead Weight, Metric Ton
95047 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DANAE R Freight Ship · MISLE 945958 · 8 March 2018 · activity 6386878

Inspection history · 12

12 June 2026 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8381534
17 February 2026 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8311537
22 August 2025 Deficiency Check · PSC B · Appeal
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8213306
19 August 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8213063
19 July 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7739909
11 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7740025
15 May 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7184464
15 October 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6834740
28 May 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6695664
8 March 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6386878
2 January 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6327976
20 October 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6021789

Deficiency record · 15

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 22 August 2025 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. The technical and/or operational nature of the deficiencies noted in deficiencies 02 and 10 below provide objective evidence of a serious failure of the implementation of the ISM code. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency. 74SOLAS(24) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 November 2025
Resolution: Received flag report attesting to deficiency clearance.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 22 August 2025 Resolved
When transporting a solid bulk cargo which is liable to emit a toxic or flammable gas, or cause oxygen depletion in the cargo space, an appropriate instrument for measuring the concentration of gas or oxygen in the air shall be provided together with detailed instructions for its use. Such instrument shall be to the satisfaction of the administration. PSCO observed that the Chief Mate fail to demonstrate the calibration of gas detection equipment twice. It was observed during both calibration tests, the gas detection equipment was reading inconsistent span gas numbers indicating the equipment was not operating as intended. 74SOLAS(24) VI/3.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 November 2025
Resolution: Received flag report attesting to deficiency clearance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 22 August 2025 Resolved
The construction and means for securing the weather-tightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. The no. 2 cargo hold hatches sustained substantial damage altering the construction and weather tightness due to an explosion that occurred onboard August 18th, 2025. ICLL 1966 I/14.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 February 2026
Resolution: Received class report attesting to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 August 2025 Resolved
The means for securing and maintaining weather-tightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed cargo hold access hatches between no.1 and no. 2 cargo hold severely damaged. ICLL 1966 I/16(3)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2025
Resolution: Receieved class report attesting to permanent repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 August 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed cargo hold no. 2 and its hatch cover severely damaged due to an explosion that occurred on August 18th, 2025. The condition of the vessels hull, cargo holds, tanks and overall structure are unknown. A damage assessment and full survey shall be completed by the vessels Flag State and Recognized Organization. 74SOLAS(24) I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2025
Resolution: Recieved class damage survey.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 August 2025 Resolved
The mark of the Authority by whom the load lines are assigned may be indicated alongside the load line ring above the horizontal line which passes through the centre of the ring, or above and below it. The load line indicated NK as current issuing Authority where the current issuing Authority is LR. ICLL 1966 I/7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
Resolution: Received class report attesting to proper LL markings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 August 2025 Resolved
Efficient guard rails or bulwarks shall be fitted on all exposed parts of the free board and superstructure decks. The height of the bulwarks or guard rails shall be at least 1 metre (391/2) inches from the deck, provided that where this height would interfere with the normal operation of the ship. PSCO observed severe damage to starboard and port side forward handrails due to an explosion that occurred onboard on August 18th, 2025. ICLL 1966 I/25(2)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2025
Resolution: Recieved class damage survey attesting to permanent repairs.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 22 August 2025 Resolved
The training manual shall explain the following in detail: escape systems and appliances. PSCO observed 04 different models of emergency escape breathing devices (EEBD) onboard. Vessel's SOLAS training manual only had instruction manuals for 03 make and model EEBDs onboard. 74SOLAS(24) II-2/15 2.3.4.7
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
Resolution: Received flag report attesting to deficiency clearance.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 22 August 2025 Resolved
The administration shall take steps to ensure that crews of ships are trained in the use of such equipment. Vessel ordered replacement gas for gas detection equipment with incorrect chemical concentrations for cargo on board. Replacement bottles contained isobutane instead of the required methane component. Annex 9 of IMSBC outlines that the ship shall be suitably fitted and carry on board appropriate instruments for measuring the following without requiring entry in the cargo space: .1 concentration of methane in the atmosphere. Master and Chief Mate were unable to identify proper replacement span gas for on-board equipment. Vessels SOLAS training manual states: Senior Crew members should be familiar with the operational characteristics (instrument settings, type of sensors installed etc.) and the calibration procedure of the gas measuring instruments. 74SOLAS(24) VI/3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2025
Resolution: Received flag report attesting to deficiency clearance.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 August 2025 Resolved
If hydrostatic release is used in float-free arrangements, it shall: if disposable, in lieu of the requirement in paragraph 4.1.6.3.6 be marked with the means of determining its date of expiry. Vessels disposable hydrostatic releases were not marked. 74SOLAS(24) III/34 LSA 4.1.6.3.8
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 November 2025
Resolution: Received flag report attesting to deficiency clearance.
14 - Pollution Prevention › 148 - Ballast Water › Ballast water logs/records
Issued 22 August 2025 Resolved
Certification of accurate information. Include the master, owner, operator, agent, person in charge, or responsible officer's printed name, title, and signature attesting to the accuracy of the information provided and that the activities were in accordance with the ballast water management plan required by § 151.2050(g). PSCO observed ballast water management log was missing Master signatures on pages 20,21 and 22. 33 CFR 151.2070(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 September 2025
Resolution: PSCO observed required master signatures IAW with ballast water management plan.
Engineering › Steering Gear System › Piping
Issued 2 January 2018 Resolved
1499 Other(Prop. & Aux Machinery) The machinery associated piping system and fitting shall be of design and construction adequate for the service for which they are intended. During the steering gear test, hydraulic oil was observed leaking from the rotor seals. SOLAS 74(09)II 1/26.1 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 2 January 2018
Resolved 6 January 2018
Resolution: Repaired seal on the hydraulic steering, tech and class surveyed. Deficiency cleared.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 2 January 2018 Resolved
0750 (Fire Prevention)- The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: Structural fire protection of openings and penetrations in these divisions. Doors for the engine control room, emergency exit door next to the engine control room, door from galley leading to dry stores have inoperable latching mechanisms. SOLAS 74(09)II-2/ 14.2.1.1.1 10c
Action required: 705 - Other - as specified
Due 2 January 2018
Resolved 2 January 2018
Resolution: Doors adjusted to satisfaction the the U.S. Coast Guard.
Fire Fighting › Structural - A Class Divisions › Hose Ports
Issued 2 January 2018 Resolved
0750 Fire Prevention- A Class Divisions shall be so constr4ucted as to be capable of preventing the passage of smoke and flame. Cable penetrations from cable duct to passage way on Deck D were not properly insulated, which could allow for the passage of smoke. SOLAS 74(04) II-2 3.2.4 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 January 2018
Resolution: Received NKK Class report stating Wi-Fi cable penetrations in cable duct were sealed with non- combustible material.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 20 October 2016 Resolved
0611 - Lifeboat inventory - Before the ship leaves port and at all times during the voyage, all life-saving equipment shall be in working order and ready for immediate use, PSCO observed 5 life boat rations in the life boat not air tight as required by LSA code 4.4.8.12 - SOLAS 74a (2009) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 October 2016
Resolution: Recieved, reviewed and accepted proper documentation from vessels Master stating the deficiency was rectified. Ships replaced bad food rations

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.