DANAE R

DANAE R is a 2006 freight ship. The Coast Guard has recorded 16 inspections since 2008, most recently in October 2023, along with 7 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 2008 to 2023. Most recent: inspection, 14 October 2023.

Built
2006
Last inspected
14 October 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9316878 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
945958
Flag
BAHAMAS, THE
—
Maury page id
psix-945958

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (2008–2023)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38888 - Convention (Subpart B), Gross Ton
25194 - Convention (Subpart B), Net Ton
75740 - Dead Weight, Ton
85576 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

W-SAPPHIRE Freight Ship · MISLE 1196372 · 8 March 2018 · activity 6386878

Inspection history · 16

14 October 2023 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7798745
12 October 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7807588
3 October 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7802689
3 October 2023 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7807389
10 February 2022 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7393775
19 March 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6928848
9 December 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594496
8 December 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6593990
7 December 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6589011
8 March 2018 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6368752
8 March 2018 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6386878
1 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6362876
27 October 2017 ISPS II Exam · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6293130
31 July 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950170
26 March 2014 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4823563
7 May 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3193007

Deficiency record · 7

10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 10 February 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 March 2022
Resolution: Class issued certiticate allowing for vessel to maintain expired battery until 10May2022 due to Covid-19 supply chain issues.
Engineering › Generator (propulsion/auxiliary-electric) › Bus
Issued 27 October 2017 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. GENERATOR #1 IS OUT OF SERVICE DUE TO FIRE, NOT OPERATED AS INTENDED. 74 SOLAS (14 CONS)I/11 16ac
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 1 March 2018
Resolution: Vessel reported repairs to the No.1 generator. LR class report received attesting to repairs and removal of condition of class.
Engineering › Steam Boiler (auxiliary/waste heat) › Furnace
Issued 27 October 2017 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AUX BOILER FOR VESSEL IS NOT OPERATIONAL DUE TO FIRE. 74 SOLAS (14 CONS) I/11 17ac
Action required: 705 - Other - as specified
Resolved 8 November 2017
Resolution: WITNESSED SATISFACTORY OPERATION OF THE BOILER SYSTEM AND ITS ALARMS, IN THE PRESENCE OF THE USCG PSCO AND CLASS SURVEYOR.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 27 October 2017 Resolved
MAIN ELECTRIC LIGHTING SYSTEM SHALL PROVIDE ILLUMINATION THROUGHOUT PARTS OF THE SHIP NORMALLY ACCESSIBLE TO AND USED BY PASSENGERS OR CREW. SHALL BE SUPPLIED FROM THE MAIN SOURCE OF ELECTRICAL POWER. LIGHTING IN THE ENGINE ROOM FROM THE ENGINE CASING DOWN TO THE THIRD DECK IS NOT OPERATIONAL DUE TO FIRE. 74 SOLAS (04 CONS) II-I/41.2.1 17ac
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 1 March 2018
Resolution: Received full term Cargo Ship Safety [name withheld] attesting to proper operation of damaged lighting.
Construction/Loadline › Structures › Deck Plating
Issued 27 October 2017 Resolved
SATISFACTORY MEANS IN THE FORM OF GANGWAY, UNDERDECK. ETC.. SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW... IN THE NECESSARY WORK OF THE SHIP. SURROUNDING DECK PLATES AND ACCESS AROUND AREA OF FIRE ARE WARPED/WORN. ICLL ANNEX 1 REG 25 (4)
Action required: 705 - Other - as specified
Due 10 November 2017
Resolved 9 November 2017
Resolution: CLASS/FLAG ISSUED REQUIREMENTS FOR ISM TRAINING IN THE LOCALITY OF THE DAMAGE, AS WELL AS MARKING THE AREA OFF. WITNESSED IN THE PRESENCE OF THE USCG PSCO AND CLASS SURVEYOR.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 October 2017 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. Vessels 24V DC Panel is showing several failures for various alarms to which systems are tied into. PSC Examiner was unable to test: (1) bilge H/L Alarm and Steering Gear Alarms: (1) Loss of Power (2) Low-level alarms. All issues are due to fire location and severity. 74 SOLAS (14 cons) II-1/40.1.2 17ac
Action required: 705 - Other - as specified
Resolved 8 November 2017
Resolution: PSCO AND CLASS SURVEYOR TESTED ALL ALARMS RELATED TO STEERING GEAR AND HIGH BILGE LEVEL. ADDITIONAL ALARMS WERE TESTED RELATATING TO THE DIESEL GENERATORS, BOILER SYSTEM, AND MAIN ENGINE.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 March 2014 Resolved
On 12 February, 2014, M/V MARITIME HARESHIO transited through the Western Alaska Captain of the Port zone without a valid Geographic Specific Appendix for western Alaska in their non-tank vessel response plan.
Due 26 March 2014
Resolved 26 March 2014
Resolution: A letter of warning was issued to the operating company, MSI SHIP MANAGEMENT (QINGDAO) CO., LTD. on 26 March 2014.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.