Records from 1992 to 2025. Most recent: inspection, 23 April 2025.
Documentation record
Registered dimensions (L × B × D)56.8 ft × 22.0 ft × 8.4 ft
Registered tonnagegross 102 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBLDRS & REPAIR · HOUMA, LA, UNITED STATES · built 1972
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it69 - Regulatory (Subpart C or D), Net Ton
102 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
23 April 2025
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8117895
6 May 2020
Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6998572
31 May 2018
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6430240
9 April 2018
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6394067
20 March 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6128814
3 November 2016
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6042820
30 October 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6034410
10 May 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5176807
4 April 2013
Industry Initiated Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4562628
6 February 2013
DAPI Audit
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4529351
27 October 2012
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4677970
27 March 2011
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3994651
2 December 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3906942
18 November 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3896261
23 July 2010
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3808173
10 March 2010
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3693416
28 January 2010
Industry Initiated Exam · MARPOL · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3671771
21 April 2009
Deficiency Check · Administration
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3457720
18 March 2009
MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3453262
7 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3111424
17 November 2007
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3136544
5 November 2007
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3095618
26 October 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2522617
14 September 2005
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2493930
17 May 2005
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2374159
21 January 2005
MTSA Verification · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2276700
2 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957634
23 June 2001
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 291329
7 January 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 97462
11 May 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95374
4 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281
13 July 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 62586
21 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 158585
7 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 89408
25 February 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 155788
11 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111820
2 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 58643
2 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 144804
29 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 88175
25 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 81028
13 December 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 56116
2 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9902
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 November 2007
Resolved
Coast Guard Light List outdated (March 2004) needs replacement as required under 33 CFR 164.72
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 7 December 2007
Resolution: Updated Light List now on board.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 5 November 2007
Resolved
MSD missing placard with operation and safety instructions as required under 33 CFR 159 .59.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 5 November 2007
Resolution: Corrected on the spot. MSD placard posted.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 November 2007
Resolved
Port Side Remote Fuel Shutoff not working properly as required under 46 CFR 27.207.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 5 November 2007
Resolution: Corrected on the spot. Remote Fuel Shutoff repaired and working properly.
Fire Fighting › Fire Pumps › Power Source
Issued 5 November 2007
Resolved
Remote Charge Station for Fire Pump needs to be labeled with operating instructions or have ability to charge by start button as required under 46 CFR 27.301
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 7 December 2007
Resolution: New fire pump operation switch installed and operating properly at remote charge station.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 November 2007
Resolved
Non conductive mat needed at Electrical Distribution Switchboard. Good Marine Practice
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 December 2007
Resolved 7 December 2007
Resolution: Conductive mat now installed.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 September 2005
Resolved
Remote Fuel oil shut off not located at/or near the tank as required under 46 CFR 27.207
Condition: Improper Installation
Due 13 October 2005
Resolved 26 October 2005
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 14 September 2005
Resolved
PIC list for oil transfer procedures not updated as required under 33 CFR 155.740
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 14 September 2005
Resolved
Posted MSD Placard with operating and safety instructions not on board as required under 33 CFR 159.59.
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 September 2005
Resolved
Name and Hailing port not posted on stern of vessel as required under 46 CFR 67.123
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 September 2005
Resolved
Masthead and starboard Navigation lights not working as required under 33 USC 2023(a).
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Communications › Audible Communications › Bell
Issued 14 September 2005
Resolved
Fog Bell not installed as required under 33 CFR 86.05 & Inland Nav Rule 33.
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 September 2005
Resolved
Magnetic compass not illuminated as required under 33 CFR 164.72 (a)(4).
Condition: Unknown
Due 13 October 2005
Resolved 26 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 17 May 2005
Resolved
Vessel is not in compliance with 46 CFR 27.303
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 26 October 2005
Fire Fighting › Fire Pumps › Arrangement
Issued 17 May 2005
Resolved
Vessel found out of compliance with 46 CFR 27.301 required by 29APR2005.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 26 October 2005
Electrical › Mast › Lightning Ground
Issued 21 January 2005
Resolved
Condition: Damaged By Earlier Event
Due 1 February 2005
Resolved 2 February 2005
Resolution: Sighted this date
[name withheld]
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 January 2005
Resolved
Navigation Lights - Unknown Cause/Condition
Condition: Unknown
Due 1 February 2005
Resolved 4 February 2005
Resolution: Cleared issued in error.
[name withheld]
Electrical › Electric Supply System (service) › Transformer
Issued 23 June 2001
Resolved
Alarm wiring in engine room hanging loose.
Condition: Unknown
Due 23 July 2001
Resolved 4 February 2005
Resolution: Sighted this date.
[name withheld]
Navigation › Piloting/Steering › Chronometer
Issued 23 June 2001
Resolved
Marine charts of the area were not available to master.
Condition: Unknown
Due 23 July 2001
Resolved 4 February 2005
Resolution: Sighted this date all required charts onboard
Navigation › Piloting/Steering › Marine Charts
Issued 23 June 2001
Resolved
Copy of Inland Navigation rules were not available to master.
Condition: Unknown
Due 23 July 2001
Resolved 4 February 2005
Resolution: sighted this date.
[name withheld]