Records from 2016 to 2026. Most recent: inspection, 28 July 2026.
Inspection history · 37
28 July 2026
Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8449370
22 June 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8410145
20 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8377411
10 April 2026
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8345807
19 December 2025
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8285539
7 July 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8178482
3 February 2025
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8077122
18 September 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8005476
10 July 2024
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7955845
27 June 2024
Administrative Inspection · MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7965760
4 June 2024
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7927725
28 May 2024
Administrative Inspection · Internal Structural Exam · Drydock Extension
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7921535
26 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7870083
19 May 2023
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7692438
3 March 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7645017
5 February 2023
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7634079
7 November 2022
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7590464
11 August 2022
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7530554
7 June 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7470929
30 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7422316
22 February 2022
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7399661
15 April 2021
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7172886
7 May 2020
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6949973
27 April 2020
MTSA Verification · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6944923
27 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6933060
25 February 2020
Internal Structural Exam · Drydock Extension · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6915389
11 March 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6639913
30 January 2019
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6617141
21 January 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6613064
10 January 2019
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6608709
31 August 2018
In-Service Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6528226
30 March 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6382112
16 March 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6371681
9 February 2018
Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6358836
19 May 2017
In-Service Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6150451
19 February 2016
COI Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5817792
16 February 2016
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5815737
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 22 June 2026
No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026.
Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection.
33 CFR 101.650(d)(4)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 August 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 July 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protection space. Stbd side engine room machinery did not automatically secure when pre-engineered system was tested. Make pre-engineered system function as designed. 46 CFR 118.420(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2025
Resolved 8 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: External inspection of fuel tanks and inspection of tank vents, piping, and pipe fittings. Port center void had strong fuel odor. Locate source of fuel odor and make necessary correction. 46 CFR 115.804(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2025
Resolved 8 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2025
Resolved
Fire hose must be lined commercial firehose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” or hose that is listed and labeled by an independent laboratory recognized by the Commandant. Fwd hose has pin holes, replace as required. 46 CFR 118.320(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 July 2025
Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. PA system did not work on fantail or upper deck. Make necessary repair.46 CFR 121.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2025
Resolved
Life jackets must be stored in convenient places distributed throughout accommodation spaces. On upper deck there is marking for life jackets on aft bench stating that life jackets are stowed under seats when in fact they are stowed in storage bins fore and aft. Make signage accurate and ensure passenger safety brief aligns with signage. 46 CFR 117.78(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. On upper deck, 01 adult life jacket was wasted and 05 adult life jackets had wasted retro-reflective tape. Replace as required. 46 CFR 117.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 July 2025
Resolved
Each officer employed upon any vessel subject to the provisions of this subchapter must have his or her license or merchant mariner credential on board and available for examination at all times when the vessel is operating. Mate did not have MMC on board, provide copy of MMC. 46 CFR 122.402
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port and stbd machinery spaces are both equipped with two ventilation closure pull cables. One on each side did not activate closing mechanism. Diagnose, conduct operational test, and provide use for all ventilation pull cables on port and stbd sides. Make repairs and label as necessary. 46 CFR 119.465(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2025
Resolved 8 August 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 June 2024
Resolved
Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: The vital systems listed in 119.710 of this chapter.
The following vital systems on board the vessel rely on electricity to operate: fire main and steering system. The vessel is equipped with two sources of electricity (port and starboard generator). The port generator is inoperable.
Make necessary repairs to port generator, provide technical report, and conduct satisfactory operational test to the satisfaction of the attending marine inspector prior to carrying passengers. 46 CFR 120.310(a)(1)(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2024
Resolved 30 June 2024
Resolution: Backend port generator replaced with new Stanford. Inspectors satisfactory loaded tested port and starboard generators independently.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Submit CG Form 2692.
Determine root cause and analysis.
Conduct satisfactory sea trials prior to operating.
46 CFR 182.100
Action required: 705 - Other - as specified
Due 26 March 2024
Resolved 1 March 2024
Resolution: All requirments were satisfied
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 May 2023
Resolved
Fire pump pressure gauge was found to be inoperable. A spare was onboard and replaced in the presence of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2023
Resolved 19 May 2023
Resolution: A spare was onboard and was replaced in the presence of the Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 March 2023
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the MASTER of the vessel shall ensure that suitable public announcements are made informing all passengers of the location of emergency exits, survival craft embarkation areas, ring life buoys, stowage location of life jackets. USCG MI observed on 25MAR2023 that the passenger orientation was
inoperable in the enclosed passenger cabin and notified
[name withheld] Then again on 3MAR32 the same CG MI was
on the vessel and noted that the passenger orientation
was not broadcast in the upper deck. Make repairs prior to 9MAR2023. In the mean time you may utilize one of two options to remain operational.
Option 1. Close the upper passenger deck to passengers.
Option 2. Conduct Safety Orientation that includes all
required information provided verbally and visual by
a crew member demonstration each voyage with passengers. 46 CFR 122.506
Action required: 705 - Other - as specified
Due 9 March 2023
Resolved 6 March 2023
Resolution: [name withheld], Civilian MI attended the vessel at 1300 on 6MAR23 and verified proper operation of the passenger orientation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 3 March 2023
Resolved
Construction and arrangement of the vessel must allow the safe operation of the vessel. Attending MI noted that there is window missing in the main passenger cabin that is covered in PVC backer-board. Repair/Replace 46 CFR 116.100
Action required: 10 - Deficiency Rectified
Due 7 April 2023
Resolved 20 March 2023
Resolution: [name withheld], Civilian MI attended the vessel at 1545 on 20MAR23 and verified the replacement of the window.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 August 2022
Resolved
Main deck forward weathertight door has a 4" hole at the bottom adjacent to the deck coaming.
Provide repair plan proposal to [email withheld] within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2022
Resolved 19 May 2023
Resolution: Door inspected and found to be repaird to the satisfaction of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 June 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protection space.
Upon crew testing of pre-engineered fixed fire extinguishing system (fireboy), marine inspectors observed the system failed to shutdown all machinery within the machinery spaces and the override systems were not operational.
Prove proper operation of fireboy shutdowns and overrides for port and starboard machinery spaces in the presence of USCG marine inspectors.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2022
Resolution: Attended vessel in RH. Tested the Fireboy system in each hull. System successfully shut down engine and generator simultaneously, was able to be overridden, and remotely started. Repair satisfactory to the Marine Inspector. Civ Patrick Cuty
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 April 2020
Resolved
Safety Drills were not logged. Last entries were in 2019.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 1 May 2020
Resolution: New logbook entries and sheets provided to CG.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 27 April 2020
Resolved
Senior Deckhand not designated in writing per NVIC 1-91.
The employment and training of qualified deckhands is the responsibility of the marine employer (46 CFR 15.103).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2020
Resolved 1 May 2020
Resolution: Senior deckahand list provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2020
Resolved
Placed 17 Adult and 1 child pfd out of service. Passenger count reduced to 183 until new pfds are provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2020
Resolved 1 May 2020
Resolution: New PFDs provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 February 2020
Resolved
Starboard generator water pump inoperable due to broken water pump. Questioned crew who stated the water pump broke two weeks prior to the inspection. New water pump on order. Vessel is equipped with two power sources including port generator, main propulsion battery chargers, and batteries IAW 46 CFR 120.310.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 27 March 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2020
Resolved
All (04) fireboy bottles were secured with safety pins. Questioned crew and they were unaware the safety pins were in place. Observed crew remove all safety pins and discussed the critical importance of examining fire equipment before operating.
Action required: 10 - Deficiency Rectified
Due 25 March 2020
Resolved 27 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 February 2020
Resolved
Forward remote fuel shutoff valves not marked IAW 46 CFR 122.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2020
Resolved 27 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2019
Resolved
Vessel experienced choppy movement of port rudder during testing of system in synchronized mode. Upon rebooting of system, synchronized operation was inoperable. Vessel normal operation is in synchronized mode. Vessel prohibited from operation until diagnosed and corrected to satisfaction of attending USCG Marine Inspector. Vessel is allowed to transit locally between St Thomas and St John to effect repairs and conduct trials.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 March 2019
Resolution: Witness satisfactroy test of vessel steering system at dock and underway.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2019
Resolved
Installed Fireboy Pre-Engineered Fixed Firefighting Systems did not shut down all internal combustion machinery in effected spaces during test. Demonstrate shutdowns upon activation of system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2019
Resolved 25 March 2019
Resolution: Spoke with fireboy rep. System working properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 March 2019
Resolved
Port steering bilge high level alarm visual indicator not operable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2019
Resolved 25 March 2019
Resolution: Tested alarm satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2019
Resolved
Remove excess oil in both engine room bilges and on inboard side of port generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2019
Resolved 25 March 2019
Resolution: Bilges cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 March 2019
Resolved
All inflatable buoyant apparatuses found with painter line disconnected from weak link.
Action required: 10 - Deficiency Rectified
Due 11 March 2019
Resolved 11 March 2019
Resolution: Vessel attached painters. Training on proper stowage provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 January 2019
Resolved
Vessel suffered a loss of propulsion on the port engine. Diagnose cause. Repair and demonstrate proper operation to attending U.S. Coast Guard Marine Inspector prior to vessel movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 January 2019
Resolved 23 January 2019
Resolution: Vessel determined that they ran out of fuel on the port side due to improper reading of the fuel gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2019
Resolved
Steering system hunting when in synchronized mode. Demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2019
Resolved 30 January 2019
Resolution: Vessel replaced potentionmeters and demonstrated satisfactory operation.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 January 2019
Resolved
Starboard rudder angle indicator inoperable. Demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2019
Resolved 30 January 2019
Resolution: Vessel replaced indicator and demonstrated satisfactory operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2019
Resolved
Vessel reported suffering a steering loss at approximately 0630 on 10JAN2019 due to loss of hydraulic fluid. Prior to carrying passengers, demonstrate proper operation of steering system.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 January 2019
Resolved 11 January 2019
Resolution: Vessel demonstrated operation of steering system.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 August 2018
Resolved
Port side fixed firefighting system found depleted. Provide causal analysis and repair/corrective action proposal and complete repair/corrective action.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2018
Resolved 9 October 2018
Resolution: Vessel replaced leaking Fireboy cylinders.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 16 March 2018
Resolved
Rectify fixed fire detection fault.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 18 April 2018
Resolution: Vessel replaced defective head clearing fault.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 16 March 2018
Resolved
Provide servicing certificate for fixed gas firefighting system.
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 30 March 2018
Resolution: Recieved servicing report
Engineering › Steering Gear System › Feedback Unit
Issued 16 March 2018
Resolved
Diagnose and repair port rudder hunting.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 18 April 2018
Resolution: Vessel demonstrated proper operation without hunting.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 March 2018
Resolved
Provide current Certificate of Documentation
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 2 May 2018
Resolution: Cleared. Vessel does not require COD.
Engineering › Freshwater System (air cooling) › Piping
Issued 16 March 2018
Resolved
Repair leaking air conditioning piping in center void.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 May 2018
Resolution: Vessel replaced leaking joints with flexible hose connections.
Fire Fighting › Fire Pumps › Casing
Issued 16 March 2018
Resolved
Repair leaking fire pump.
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 18 April 2018
Resolution: Fire pump housing leak repaired.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 16 March 2018
Resolved
Provide training and designation of Senior Deckhands prior to utilizing Senior Deckhand in lieu of mate.
Action required: 705 - Other - as specified
Resolved 25 March 2019
Resolution: Vessel operates with two captains when carrying 150 or more passengers.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 24 May 2017
Resolved
Demonstrate proper operation of fire detection system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2017
Resolved 16 March 2018
Resolution: Detection system was operating.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 May 2017
Resolved
Complete fire drill, abandon ship drill and man overboard drills prior to carrying passengers.
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 16 March 2018
Resolution: Demonstrated fire, man overbaord and security drills.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 24 May 2017
Resolved
Show proper operation of main engines, gauges, and steering.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2017
Resolved 16 March 2018
Resolution: Vessel demonstrated operation of machinery and gauges/controls.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 24 May 2017
Resolved
Forepeak tanks gravity drain to vent compartments through collission bulkheads. Provide repair proposal to USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 28 February 2018
Resolution: Vessel welded seams on both bulkheads.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 May 2017
Resolved
Provide MMSI and GPS input to DSC radio.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 16 March 2018
Resolution: MMSI and GPS input verified.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 24 May 2017
Resolved
Service IBAs.
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 16 March 2018
Resolution: Vessel provided evidence of servicing.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 19 May 2017
Resolved
Pre-engineered fixed firefighting systems installed in both engine rooms were found with discharged cylinders. Prior to carrying passengers, install functioning and serviced fixed firefighting systems in both engine rooms to the satisfaction of the attending USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2017
Resolved 16 March 2018
Resolution: Vessel had system serviced and refitted.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 February 2016
Resolved
Service all expired portable fire extinguishers onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2016
Resolution: Corrected prior to departure from inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 February 2016
Resolved
Service fixed fire extinguishing system in port and starboard engine rooms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Engineering › Bilge Water Management System › Pump
Issued 19 February 2016
Resolved
Prove operation of port and starboard bilge pumps. Pump was not able to take suction and dewater.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2016
Resolution: Corrected prior to departure. Witnessed proper operation.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 February 2016
Resolved
Prove operation of emergency lighting in port and starboard mid-compartment and port and starboard steering gear compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 19 February 2016
Resolved
Replace missing covers on lighting fixtures in port and starboard steering compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Electrical › Lighting (service) › Switch
Issued 19 February 2016
Resolved
Prove operation of service lighting in port side steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 February 2016
Resolved
Replace broken emergency lighting fixtures in port and starboard steering compartments.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Fire Fighting › Fire Pumps › Pressure
Issued 19 February 2016
Resolved
Prove operation of pressure gauge servicing fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 February 2016
Resolved
Make name of vessel readable on all life ring buoys.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 19 February 2016
Resolved
Program radio with MMSI number for DSC and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 19 February 2016
Resolved
Provide current tide tables onboard for operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Lifesaving › Hand Flares › Quantity
Issued 19 February 2016
Resolved
Replace one missing red distress flare.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2016
Resolution: Corrected on the spot.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 19 February 2016
Resolved
Provide monthly EPIRB testing log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 February 2016
Resolved
Provide an approved first aid kit onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2016
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 February 2016
Resolved
Make vessel available to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 February 2016
Resolved
The owner failed to make vessel available to have an annual inspection within 3 months after COI anniversary of 28OCT2013. Inspection must have been conducted by 28JAN16.
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 19 February 2016