Records from 2014 to 2025. Most recent: inspection, 19 September 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 50.0 ft × 13.0 ft
Registered tonnagegross 1,600 / net 1,600
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2013
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1600 - Simplified, Gross Ton
1600 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
19 September 2025
Administrative Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8237522
21 January 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7852174
18 December 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7840318
5 December 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7843431
8 August 2023
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7762864
18 July 2023
Administrative Inspection · Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7745637
21 January 2023
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7786053
18 May 2022
Examination of Repairs · In-Service Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7454110
22 October 2019
Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6839485
17 August 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6514697
12 July 2018
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6468201
26 July 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6221674
2 August 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5961244
24 September 2015
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5730677
24 September 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5730954
18 September 2015
Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5722817
16 August 2015
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5218498
12 July 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5200103
22 April 2014
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4841343
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 May 2022
Resolved
Sector Houston-Galveston was notified of a fracture in the starboard bow transition knuckle. Fracture is above the waterline, and there is currently no water intrusion into the void space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 June 2022
Resolved 8 June 2022
Resolution: Cropped and renewed damaged portions of transition knuckle.
Construction/Loadline › Structures › Door
Issued 24 September 2015
Resolved
Fully enclosed PIC shed and Pollution prevention shed found onboard within hazardous zone. Provide approval from MSC for sheds to be onboard or remove completely.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 September 2015
Resolution: Vessel removed PIC shed from vessel. MI attended vessel and verified compliance.
Construction/Loadline › Hull › Side Shell
Issued 18 September 2015
Resolved
(1) inset found on #5 port wing void, roughly 2.5" x 12" long. Crop and renew in kind.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2015
Resolution: Vessel conducted permanent repairs of affected area. Air/Soap test satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 18 September 2015
Resolved
Cargo transfer hoses found unlabeled. Mark in accordance w/ 33 CFR 154.500.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2015
Resolution: Vessel conducted test of hoses & properly labeled IAW 33CFR154.500.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 September 2015
Resolved
Fully enclosed PIC shed and pollution prevention shed found onboard within hazardous location. Provide documenation of approval from MSC or remove completely.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 21 September 2015
Resolution: both shacks permanently removed from vessel.