OCEAN INTERVENTION II

OCEAN INTERVENTION II is a 2000 research vessel. The Coast Guard has recorded 26 inspections since 2016, most recently in April 2026, along with 31 deficiencies and 1 casualty investigation in 2002.

Records from 2002 to 2026. Most recent: inspection, 21 April 2026.

Built
2000
Last inspected
21 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9232125
WCZ7505
Flag
UNITED STATES
Maury page id
psix-1222

Documentation record

Registered dimensions (L × B × D)227.0 ft × 53.5 ft × 18.8 ft
Registered tonnagegross 2,255 / net 676
ITC dimensions (L × B × D)227.0 ft × 53.5 ft × 18.8 ft
ITC tonnagegross 2,255 / net 676
BuilderBOLLINGER SHIPYARDS LLC · LOCKPORT, LA, UNITED STATES · built 2000
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 26 August 2025 · expires 30 September 2026
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it676 - Convention (Subpart B), Net Ton
2255 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

21 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8353449
18 March 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8297181
11 April 2025 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8109947
16 January 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8064628
10 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8060735
22 April 2024 MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7899284
25 April 2023 Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7672913
9 December 2022 Administrative Inspection · Inclining Experiment
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7606833
15 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 7411953
29 October 2021 Administrative Inspection · Annual Inspection
Physical examination · Activities Europe · Activity 7341759
5 August 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7284416
8 June 2021 Annual Inspection · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 7199845
21 April 2021 Administrative Inspection
Administrative · Activities Europe · Activity 7182799
12 June 2020 Deficiency Check · Administrative Inspection · ISM Oversight
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6977605
11 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6951701
23 April 2020 MARPOL Annex VI Survey · Deficiency Check · Administrative Inspection · Ballast Water Examination · MTSA/ISPS Verification · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6942977
13 December 2019 Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 6873169
8 November 2019 Administrative Inspection
Administrative · Activities Europe · Activity 6872459
1 May 2019 Annual Inspection · MTSA/ISPS Verification · MARPOL Annex V Examination · MARPOL Annex VI Survey · Ballast Water Examination · MARPOL Annex IV Survey
Physical examination · Activities Europe · Activity 6674000
1 April 2019 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6653603
14 June 2018 Administrative Inspection · MTSA/ISPS Verification · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6443914
14 September 2017 Internal Structural Exam · Hull Examination · In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6270742
5 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6167081
25 January 2017 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6077096
16 July 2016 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5961806
15 June 2016 Administrative Inspection · MARPOL Annex IV Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5908570

Deficiency record · 31

08 - Alarms › N/A - No Subsystem › General alarm
Issued 18 March 2026 Resolved
Where general alarm signal cannot be heard over background noise ther must be a red light, flashing or rotating . Lights in machinery spaces not operable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2026
Resolved 18 March 2026
Resolution: Red lights operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 March 2026 Resolved
All fire pump remote locations must have a firemain pressure indicator. Pilot house house fire pump control indicator not operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2026
Resolved 18 March 2026
Resolution: Verified pressure gauge operable via ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2026 Resolved
Electric installation must ensure protection of crew from elecrical hazards. CB-9 and CB-3 missing blanks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 March 2026
Resolved 18 March 2026
Resolution: ABS verified blanks installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2024 Resolved
TWO SPARE CHARGES SHALL BE PROVIDED FOR EACH REQUIRED BREATHING APPARATUS. VESSEL DOES NOT HAVE A MEANS TO RECHARGE APPARATUS' AND DOES NOT HAVE ADEQUATE NUMBER OF SPARES ONBOARD. PROVIDE 02 SPARES ON BOARD. SOLAS (14) II-2/10.10.2.5
Action required: 702 - Prior to embarking on international voyage
Resolved 22 April 2024
Resolution: Spare bottles onboard.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 April 2024 Resolved
THE TYPE OF PIPING JOINT USED SHALL BE SUITABLE FOR THE DESIGN CONDITIONS AND SHALL BE SELECTED WITH CONSIDERATION OF JOINT TIGHTNESS, MECHANICAL STRENGTH AND THE NAUTRE OF THE FLUID HANDLED. PIPING TO FIREMAIN FROM EMERGENCY FIRE PUMP WAS LEAKING. CORRECTED ON THE SPOT AND WITNESSED BY ABS. 46 CFR 56.30-3
Action required: 10 - Deficiency Rectified
Resolved 22 April 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 25 April 2023 Resolved
Vessels over 400 ITC required to have an OWS. Breaker for tripped multiple time while attempting to conduct test during annual IOPP survey. MARPOL 73/78 Annex I reg 14
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 3 May 2023
Resolution: Pump replaced. Attended vessel to witness test.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 25 April 2023 Resolved
Fuel lines shall be screened or otherwise protected to avoid spray or leakage onto source of ignition. Missing tape and/or shielding on multiple generators. SOLAS 74 Cons 2014 CH II-2 Reg 4/ 2.2.5.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 3 May 2023
Resolution: Attended vessel, verified sheilds and tape in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2023 Resolved
Inspections shall insure that equipment is in a satisfactory operating condition. Generators were missing multiple fuel rail rubber grommets causing wear/thinning of fuel line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 3 May 2023
Resolution: Attended vessel verified grommets and brackets in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2023 Resolved
Non-metallic flexible hose must be IAW SAE J1942. Fuel hoses were missing markings and could not be verified to be in compliance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2023
Resolved 3 May 2023
Resolution: Attended vessel verified multiple hoses replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2022 Resolved
The company should establish procedures, plans and instructions,including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various task should be defined and assigned to qualified personnel. The following observations were made regarding the vessel's confined space entry program: -The SMS did not identify personnel responsible for the vessel's confined space entry program. -The span gas for calibrating the gas detection expired in 2020. -No maintenance procedures for maintaining the gas detectors. -The gas detector maintenance log was not an SMS form and the last calibration date was APR 2021. -The manual for the gas detector(s) differed from the equipment on board the vessel. -In the ship's certificate binder, the last calibration certificate for the gas detector was from 2019. The following observations were made from the vessel's Lock-out Tag-out program: -Entries for the Lock-out Tag-Out were made in the ship's log book and not entered in accordance with SMS. The fire pumps were identified as Locked-Out but were energized and put back into service at unknown date. -The vessel had not utilized the lag out tag out approved form that had been provided by the company via the SMS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 30 April 2022
Resolution: SMS was reviewed and satisfactory to the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 7 February 2022 Resolved
A device that can continuously record the depth readings of the vessel's echo depth sounding device ...The vessel's installed echo depth sounder was not enable to record depths. The installed depth sounder could not demonstrate the ability to maintain 12 hours or record IAW w/ MSC.74(69).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 7 April 2022
Resolution: Deficiency rectified and verified by the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 7 February 2022 Resolved
Logs of ship stations which are compulsorily equipped for radiotelephony must contain the following applicable log entries and the time of their occurrence; a weekly entry that the proper functioning of digital selective calling (DSC) equipment has been verified by actual communications or a test call. The vessel's logs did not routinely capture logging the DSC functionality and/or tests. 47CFR 80.409(e)(6)(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 18 March 2022
Resolution: Logs have been updated and aligned to capture DSC tests.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 7 February 2022 Resolved
Design verification and Periodic Safety Test procedures described in subpart 61.40 of the chapter shall be submitted to MSC for approval. Test procedures shall be witnessed by an attending Marine Inspector IAW 46CFR 61.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2022
Resolved 18 March 2022
Resolution: MI witnessed PSTP's.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 February 2022 Resolved
The boundary bulkheads and decks separating the accommodations and control stations from cargo and machinery ...The main door to EOS from engine room has a worn and wasted handle/lock mechanism. Provide appropriate assembly for A-60 rated door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 18 March 2022
Resolution: EOS door had been repaired and handle secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2022 Resolved
Each fixture globe, lens, or diffuser must have a high strength guard or made ...The port side bulkhead in the engine room had a wasted/busted diffuser. Provide proper guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2022
Resolved 18 March 2022
Resolution: Globe renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 October 2021 Resolved
During the term of a vessel's certification of inspection, the vessel must be in compliance with its conditions...When a vessel is not in compliance with its certificate or fails to meet a standard prescribed by this part or a regulation prescribed under this part the owner, charterer, managing operator, agent, master, or individual in charge shall be ordered in writing to correct the noted deficiencies promptly. Vessel is currently conducting operations outside the scope of its subchapter "L" COI by not operating in support of exploration, exploitation, or production of offshore mineral or energy resources. Vessel is currently pursuing a multi-certification COI for compliance with subchapter "I" and “L”. Complete multi-certification process.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2021
Resolved 31 December 2021
Resolution: Vessel is in compliance with subcahters "L" & "I".
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 12 August 2021 Resolved
The certificate of inspection issued to a vessel shall state the compliment of licensed individuals and crew. A vessel may not be operated without having in its service the compliment required in the certification of inspection. Chief Engineer did not hold the required endorsement to serve as a Chief Engineer on board this vessel with 4,000 horsepower as listed on the COI. 46 USC 8101 (d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 20 August 2021
Resolution: Recieved current IMO crew list reflects full manning as well as a properly credentialed CHENG.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 12 August 2021 Resolved
The certificate of inspection issued to a vessel shall state the compliment of licensed individuals and crew. A vessel may not be operated without having in its service the compliment required in the certification of inspection. The IMO crew list with date of arrival/departure August 1, 2021 does not list one Ordinary Seaman as listed on the COI. 46 USC 8101 (d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 26 August 2021
Resolved 20 August 2021
Resolution: Recieved current IMO crew list reflects full manning as well as a properly credentialed CHENG.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Vessel recalled previous CHENG who processed III/2, and III/3 for STCW.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 June 2021 Resolved
Each self-propelled vessel must have a navigation light indicator panel in the navigating bridge to control side, mast and stern lights. The panel must visually and audibly signal the failure of each of these navigation lights. Upon testing, the port side light, primary element did not alarm when the fuse was removed.
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Ship's ET found and repaired a compressed spring, which prevented proper alarming of the circuit, tested SAT for MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2021 Resolved
Lifebuoys fitted with smoke signals must also be fitted with lights. When tested, the STBD light for the bridge ring buoy did not work.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Light was immediately replaced by ship's crew when discovered.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 June 2021 Resolved
Each general alarm bell must be identified by red letters at least 1/2" high that state the following: "GENERAL ALARM-WHEN BELL RINGS GO TO YOUR STATION". Many of the GA bells and speakers were missing their markings.
Action required: 10 - Deficiency Rectified
Due 8 July 2021
Resolved 9 June 2021
Resolution: Vessel provided pictures that all alarms were labled the following day.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 June 2021 Resolved
Electrical equipment exposed to the weather must be watertight. The E-Stop for the crane hydraulics pump had a broken indicator light cover and was no longer waterproof.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 June 2021
Resolution: Ship's crew replaced the switch and sent a picture of the newly installed item.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 May 2020 Resolved
46 CFR 127.100 Vessel has three workspace Portable Accommodation Modules (PAMs) that are not properly documented in accordance with PAM guidance CG-ENG Policy Letter 01-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2020
Resolved 12 June 2020
Resolution: Vessel PAMs have been documented correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 May 2020 Resolved
46 CFR 128.110(a) 46 CFR 61.40-6 Vessel was unable to test low lube oil pressure shutdowns and high jacket water temp alarm for diesel engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 June 2020
Resolution: Vessel Captain provided a CG letter attesting to this def being a non-issue. The engines were tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2019 Resolved
Establish a tracking program for the purpose of monitoring the replacement of non metallic expansion joints. 46 CFR 61.15-12 (b), vessel has no record of replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 18 June 2019
Resolution: Cleared via email
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 May 2019 Resolved
Firefighters out fits shall be equipped with an axe with a a handle provided with high voltage insulation. FSS Chapter 3.2.1.1.5. Shipboard FFE's don't currenlty have an axe.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 18 June 2019
Resolution: Cleared via email
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 May 2019 Resolved
Lifebuoys intended to operate with the quick releae arrangements shall have a mass of not less than 4 kg and be USCG approved under 46 CFR sub chapter Q. Vessel only has 2 kg liferings. LSA Code Chapter II 2.1.1.7
Action required: 15 - Rectify deficiencies by next port
Due 13 May 2019
Resolved 18 June 2019
Resolution: Cleared via email
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2019 Resolved
The vessels haling port must be marked on some clearly visible exterior part of the stern of the vessel. The current marking does not reflect the correct haling port. Correct during next dry dock.
Action required: 705 - Other - as specified
Due 30 March 2020
Resolved 15 June 2020
Resolution: This def has been cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 May 2019 Resolved
Inflatable liferafts must be serviced at a facility specifically approved by the Commandant for the particular brand no later than the month and year on its servicing sticker, except that servicing may be delayed until the next scheduled inspection of the vessel, provided that the delay does not exceed 5 months. Vessel's complement of liferafts were due for servicing on 01Jun2019. A five-month delay is approved; annual servicing must take place no later than 01Nov2019.
Action required: 705 - Other - as specified
Due 1 November 2019
Resolved 25 September 2019
Resolution: Received new inspection certificate via email from the vessel agent. All Sat.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 15 June 2016 Resolved
ABS had not completed Loadline Survey prior to the completion of the USCG inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2016
Resolved 17 June 2016
Resolution: ABS completed loadline survey and signed documentation

Casualty record · 1

14 December 2002Routine · role: Involved in a Marine Casualty · activity 1744016
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.