Records from 2013 to 2026. Most recent: inspection, 21 July 2026.
Inspection history · 31
21 July 2026
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8444256
21 July 2026
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8444480
16 March 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8326760
22 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8116871
2 April 2025
Drydock Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8104052
13 August 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7981395
22 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7916705
17 April 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7897154
22 March 2024
Drydock Extension
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7883597
3 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7710837
28 April 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7434224
14 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411614
19 August 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7328589
7 August 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333552
2 February 2021
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7134311
30 December 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7117681
20 September 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7063003
6 July 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7035632
16 December 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6874639
23 August 2019
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6792412
14 April 2019
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6663093
14 April 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6684376
25 February 2019
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6632166
13 February 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6625135
25 September 2018
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6544375
13 December 2017
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6323156
30 November 2017
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6315992
9 June 2017
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6216221
15 May 2017
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6146668
29 November 2016
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6049173
4 April 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5847010
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found part of the guard was missing on the starboard main engine which exposed the gear of the alternator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 5 June 2024
Resolution: Received photo of machinery guard in place on the MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2023
Resolved
65 lifejackets found to be wasted, replace wasted life jackets. Passenger count reduced by 65.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: 65 lifejackets purchased by vessel rep.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 3 May 2023
Resolved
PA systems was found to be inop, repair or replace PA system.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2023
Resolution: Technician repaired PA system, vessel rep emailed video of functioning PA system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 December 2020
Resolved
Provide vessel with 07 adult life jackets. Vessel's passenger count is reduced to 131 until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 14 January 2021
Resolution: Received photo and invoice from vessel rep of corrected def.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 30 December 2020
Resolved
Prove proper operation of vessel's stern light. Vessel is restricted from night operations until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2021
Resolved 14 January 2021
Resolution: Received photo and invoice from vessel rep of corrected def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 December 2019
Resolved
Clean debris from bilge in tank space. Due 17Jan2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 19 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 December 2019
Resolved
Replace damaged quick release pin for boarding gate. Due 17Jan2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 19 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2019
Resolved
Remove dead-end wires from under bridge console. Due 17Jan2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 19 February 2020
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 December 2019
Resolved
Replace defective fire hose.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 17 December 2019
Resolution: Replaced hose.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 December 2019
Resolved
Install spanner wrench at fire station.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 December 2019
Resolution: Installed wrench.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 April 2019
Resolved
Main engine shutdown/loss of propulsion. Operator claims low fuel lead to air in the fuel line causing the engine to shutdown. New policy states the fuel tanks must be at 150 gallons before crew starts operations.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2019
Resolved 20 April 2019
Resolution: Sea trials conducted. Fuel tanks filled. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2019
Resolved
Make permanent repairs to significant oil leak on the starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2019
Resolution: Gasket replaced, stbd MDE ran 100% for 10 min - sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 February 2019
Resolved
Prove proper operation of propulsion machinery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2019
Resolution: Hamilton Jet technician replaced port side jet control module, conducted underway sea trial, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Provide retro refective tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2018
Resolved 1 October 2018
Resolution: Retro tape provided.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 September 2018
Resolved
Repair cracked swim step.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 5 October 2018
Resolution: Swim step repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 25 September 2018
Resolved
Repair crack on hand rail at stern light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 5 October 2018
Resolution: crack repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 September 2018
Resolved
Provide NDT on potential crack starboard side in lazz.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2018
Resolution: NDT completed. Report submitted on 17 Oct 2018.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2018
Resolved
Replace outlet breaker in storage closet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 5 October 2018
Resolution: Outlet breaker replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2018
Resolved
Label missing circut and fill void on panelin storage circut.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 19 October 2018
Resolution: Label provided and void filled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 September 2018
Resolved
Replace hyme joint or bushing at starboard steering bucket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 25 October 2018
Resolution: Hyme joints replaced.
Fire Fighting › Nozzles › Condition
Issued 13 December 2017
Resolved
Varying nozzle was not functioning thru all patterns.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2018
Resolved 14 December 2017
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 29 November 2016
Resolved
Provide additional visual distress signals 6 & 6; vessel restricted lo Lakes, Bays, and sounds toute
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: The proper amount of visual distress signals are now onboard.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 29 November 2016
Resolved
Install inflatable buoyant apuratus as per the vessel's COI; vessel is restricted to Lakes, Bays and Sounds route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: IBA is now onboard and installed in float free arrangement.
Communications › Alarms/Indicators › High Water Alarm
Issued 29 November 2016
Resolved
Provide visual indicators for the bilges in the steering and engine compartment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: Witnessed proper operation of the high level alarms.