ADVENTURE HORNBLOWER

ADVENTURE HORNBLOWER is a 1994 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 2016, most recently in October 2025, along with 118 deficiencies, 1 operational control and 15 casualty investigations between 2006 and 2025.

Records from 2006 to 2025. Most recent: inspection, 9 October 2025.

Built
1994
Last inspected
9 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 October 2025
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA3017
399093
Flag
UNITED STATES
Maury page id
psix-399093

Documentation record

Registered dimensions (L × B × D)142.8 ft × 33.0 ft × 10.5 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)142.8 ft × 33.0 ft × 10.5 ft
ITC tonnagegross 686 / net 205
BuilderWASHBURN & DOUGHTY ASSOCIATES INC · EAST BOOTHBAY, ME, UNITED STATES · built 1994
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
686 - Convention (Subpart B), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
205 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

INSPIRATION HORNBLOWER Passenger (Inspected) · MISLE 374158 · 27 November 2022 · activity 7609320CABRILLO Passenger (Inspected) · MISLE 44726 · 4 April 2016 · activity 5847010PATRIOT Passenger (Inspected) · MISLE 1234283 · 4 April 2016 · activity 5847010

Inspection history · 44

9 October 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8245929
1 July 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8178172
14 May 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8135760
6 September 2024 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8026893
5 September 2024 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7998012
18 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7939127
30 November 2023 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7862342
22 November 2023 Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7828506
5 October 2023 Internal Structural Exam · Examination of Repairs · Permit to Proceed · Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7794155
30 May 2023 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7701349
15 May 2023 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690061
15 May 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7713133
12 May 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7690059
12 May 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7701646
23 March 2023 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7643090
11 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649640
23 January 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7625925
14 December 2022 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609308
27 November 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609320
26 November 2022 Damage Survey · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7600857
5 October 2022 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7572363
28 June 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7486197
8 December 2021 Construction Oversight · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7364810
25 October 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7335931
23 June 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7233648
24 March 2021 Deficiency Check · Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7162632
20 October 2020 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7082127
24 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6985520
6 March 2020 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6922085
21 January 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6892966
20 January 2020 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6896971
16 October 2019 Deficiency Check · Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835549
25 June 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6725281
10 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6710846
28 November 2018 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596794
14 September 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6538237
27 March 2018 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6378712
6 November 2017 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6301563
18 October 2017 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6290332
27 June 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6188238
4 September 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6004523
4 August 2016 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6005986
4 April 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5847010
31 March 2016 Annual Inspection · Damage Survey · Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5845243

Deficiency record · 118

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2024 Resolved
Identify the cause of the starboard MDE/transmission failure and enact an appropriate repair. A satisfactory sea trial must be completed in the pressence of a USCG marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 September 2024
Resolution: Affected part was replaced. Witnessed satisfactory sea trial.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2024 Resolved
Observed expired alcohol swabs. Vessel is to replace swabs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2024
Resolved 20 June 2024
Resolution: Vessel POC provided images of new test swabs.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 June 2024 Resolved
Compass light was not operational. Vessel is to ensure compass light is operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2024
Resolved 26 June 2024
Resolution: Received picture of repaired light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2024 Resolved
Observed Aft portside terminal box on weather deck was missing a cover. Vessel is to replace cover or terminal box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2024
Resolved 26 June 2024
Resolution: Received picture of new faceplate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2023 Resolved
Repair/replace aft door on second deck due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 November 2023
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2023 Resolved
The general construction of the vessel must be as such as to minimize the fire hazards in so far as it is reasonable and practicable. MI identified missing insulation in laz on portside overhead. 46CFR116.405(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2023
Resolved 29 June 2023
Resolution: Installed insulation
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2023 Resolved
Each window, port hole and its means of attachments to the hull or deckhouse must be capable of withstanding the maximum load from wave or wind conditions expected due to its location on the vessel and the authorized rout of the vessel. MI identified cracked glass in LAZ exit door on main deck. 46CFR116.1020
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 30 November 2023
Resolution: replaced
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 May 2023 Resolved
A door must not be undercut more than .5 inches above the door sill. MI identified bottom of door on main deck exiting to back deck/laz chipping/rusting away on bottom portion. 46CFR116.435(c)(5)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2023
Resolved 30 November 2023
Resolution: replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other person and the vessel from electrical hazards, including fire caused by originating in electrical equipment. MI observed outlet in galley space to be taped and secured in the off position. 46CFR120.200
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2023
Resolved 29 June 2023
Resolution: Replaced outlet in galley space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2023 Resolved
On 15MAY2023, It was reported that the ADVENTURE HORNBLOWER lost propulsion on their approach to the dock. Vessel operators must identify the cause of the loss of propulsion and submit a report/description to the OCMI detailing the events. USCG must witness satisfactory propulsion prior to the carriage of passengers and request permission to shift within the port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: Witnessed satisfactory test of MDEs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 May 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2023
Resolution: MI's witnessed satisfactory operation of generators and main engines
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
Junction box on no.3 deck port side IWO aft stairwell found to be not secured. Secure junction box to prevent movement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 21 August 2023
Resolution: Mounted Junction Box.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 March 2023 Resolved
A means of escape that is not readily apparent to a person from both inside and outside the space must be adequately marked in accordance with 46 CFR 122.606.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 21 August 2023
Resolution: Labeled emergency escape door
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2023 Resolved
Tubular gauge glasses must be adequately protected from mechanical damage. Need to add two (02) more protection rods to the gauge glass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 21 August 2023
Resolution: Installed sight glass protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
Nonconducting mat must be provided in front of the engine space distribution box next to the switchboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 13 June 2023
Resolution: Installed non-conductive matting
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 March 2023 Resolved
Must provide bilge high level alarm in the fuel tank/DPF space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 21 August 2023
Resolution: Installed high level alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2023 Resolved
Multiple exposed wires were found in the wheelhouse under the console, adjacent to the windshield wiper switches and on the port side overhead while leaving the wheelhouse. All wires in use need to be properly terminated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 13 June 2023
Resolution: Properly terminated dead end wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2023 Resolved
The remote start for the vessel's starboard MDE is inoperable. Repair the remote start and test in the presence of a USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2023
Resolved 16 March 2023
Resolution: Verified remote operation from three (03) stations; [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 December 2022 Resolved
A failed gasket on the bow thruster is leaking water into the bow thruster void. Enact permanent repairs to the bow thruster leak. Hourly rounds of the space must be conducted until the vessel is repaired or hauled out to verify that pumping arrangements are keeping up with the leak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2022
Resolution: Gasket has been replaced and leaking has stopped.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 November 2022 Resolved
Vessel suffered a 6ft x 1ft gash along the port quarter into the steering gear room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2022
Resolution: Witnessed NDT and observed final weld of insert. [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 November 2022 Resolved
Due to the nature of the allision, the vessel will be required to demonstrate proper transfer of controls to and from the bridge wings in accordance with manufacturer requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 November 2022 Resolved
Non-metallic conduit on the aft end of Port Diesel Particulate Filter melting during operation. Verify cause of the melting and implement a manufacturer approved repair/correction. Deficiency must be rectified prior to departure.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2022
Resolution: Observed extension jacket fabricated for conduits. [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 October 2022 Resolved
Vessel operator notified USCG that all I.B.A.s will be removed from vessel for annual servicing. To continue to operate, the vessel must: a). Be restricted to Lakes, Bays and Sounds route inside the San Diego Bay and not cross the boundary line in accordance with 46 CFR 7.120(a). b). While transiting inside San Diego Bay, cannot be more than one (1) mile from land in accordance with 46 CFR 117.207. Vessel may return to normal routes in accordance with their C.O.I. upon return of all I.B.A.s from the service facility.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2022
Resolved 12 December 2022
Resolution: Received servicing documentation for all 06 IBA's. Verified all IBA'a properly installed / stowed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 June 2022 Resolved
The exhaust system on the starboard auxiliary engine including the DPF ingested a significant amount of sea water. As a result, the filter system is no longer functional and will need to be replaced to the satisfaction of the Coast Guard. The ship operator must continue to monitor the back pressure monitoring system and maintain engine operation within the manufacturers recommendation while permanent repairs are made to the system. All failures/safety infractions of the system must be immediately reported to the Coast Guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2022
Resolved 1 September 2022
Resolution: Conducted final tests of the DPF and saw never flapper installed on the port exhaust. DEM
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
Non-metallic conduit on the aft ends of both Diesel Particulate Filters (DPF) began melting during operation. Verify cause of the melting and implement a manufacturer approved repair/correction. Deficiency must be rectified prior to operation of either engine fitted with a DPF. Since the vessel will not be able to power vital systems from a secondary source of power, this deficiency must be rectified prior to departure. Cites: 46 CFR 120.220 46 CFR 183.01-10(a) (Old T) 46 CFR 111.10-3 (1993)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2022
Resolution: Had conference call between DMI, CID, and president of the DPF manufacturer.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 June 2022 Resolved
Emergency lighting failed in the following locations: in the vicinity of (IVO) Fire Stations #2,#3, #4, #5, and the galley. Repair or replace the identified emergency lighting installations. Vessel may only operate during daylight hours until this deficiency is rectified. Cite: 46 CFR 184.30-5 (Old T)
Action required: 705 - Other - as specified
Resolved 25 August 2022
Resolution: Witnessed satisfactory test of e-lighting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
Raw water overboard pipe on forward generator had a leaking patch. Complete permanent repairs to this pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: Damaged section of pipe was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022 Resolved
Several improperly terminated wires found above the ceiling tiles IVO the port cargo door. Properly terminate these wires either with wire nuts in a junction box or with pressure type connectors. Cite: 46 CFR 183.05-50(b) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: Wires were properly terminated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022 Resolved
Two (02) improperly terminated wires found in the tank space forward of the engine room. Properly terminate these wires either with wire nuts in a junction box or with pressure type connectors. Cite: 46 CFR 183.05-50(b) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: Identified wires were removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. 03 junction boxes identified during the inspection not secured. Mount J-boxes to prevent movement. Cite: 46 CFR 183.01-15(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 2 December 2022
Resolution: Junction boxes secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2022 Resolved
Junction box on upper deck aft of food service area found to be missing cover. Install new weather tight cover. Cite: 46 CFR 183.01-15(a) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 25 August 2022
Resolution: A new cover was installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 June 2022 Resolved
First aid kit found to be missing Ammonia inhalants and Aspirin. Re-stock first aid kits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 12 July 2022
Resolution: Received email with proof of replacement equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2022 Resolved
The aft-most air receiver in E/R was leaking air from the relief valve. Replace valve and perform a new test in the presence of a USCG marine inspector. Cites: 46 CFR 119.330 46 CFR 54.15-10(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2022
Resolved 2 December 2022
Resolution: Relief valve tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2022 Resolved
A deficiency requiring the development and approval of a Qualitative Failure Analysis and Design Verification Test Procedures in accordance with 46 CFR 121.100(b), first issued in December of 2021, has not yet been satisfied. Additionally, the DPF system onboard suffered a casualty through an unanticipated failure mode which resulted in overheating components melting an electrical conduit and the filter media being damaged. Prior to movement of the vessel, DVTP's must be completed based off of a procedure approved by the Marine Safety Center to the satisfaction of the attending Marine Inspector. The DVTP's must be developed using a QFA which considers the failure modes outlined in MSC letters E1-2103519, comment 2, as well as the failure which was observed onboard during the recent casualty. Additionally, all outstanding comments from letter E2-2201566 must be resolved prior to shipboard testing.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 September 2022
Resolution: Tested all systems SAT IAW the DVTP submitted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 December 2021 Resolved
Sector San [name withheld] has determined that the control system for the DPFs aboard ADVENTURE HORNBLOWER warrant additional review. Prior to operating the DPF system in the San Diego [name withheld], a QFA and DVTP must be developed and submitted to the MSC for review and approval, and DVTPs conducted to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2021
Resolution: Tested DVTP submitted to SSD [name withheld] def added for submittal to MSC for review.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 December 2021 Resolved
Machinery Exhaust Gas must not leak. Forward generator exhaust leaks at the engine to piping system (near turbo).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 December 2021
Resolution: Vessel captain provided statement, receipt and photo of flang leak properly repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 December 2021 Resolved
A Class fire boundary. Port aft passenger cabin (02 level) fire door labeled "Smoke and Draft control requires class H gasket" but half the fire door gasket is missing, and appears to be weather strip.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 December 2021 Resolved
Protection against hot piping. Piping over 150 degree must be insulated. Following sections need insulation: 3' on aft gen exhaust, 1' on foward gen elbox (in exhaust space), 1' on forward gen exhaust (through hull), and both Port and Stbd MDE at the engine room bulkhead penetration.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Pictures sent as proof...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 December 2021 Resolved
All cable and wire must be secured with metal supports every 24". Starboard DPF thermocouple wire 8' run is hanging in the DPF space.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2021
Resolution: Pictures sent as proof...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2021 Resolved
Electrical junction box on top of pilot house found to not be secured to a stationary surface. All electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2021
Resolved 4 August 2021
Resolution: Verfied box was secured during def check. [name withheld]
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 June 2021 Resolved
The Shutoff valve at the tank shall be operable from outside the tank compartment. Remote fuel shutoff was inoperable. Repair remote fuel shutoff valve. Cite OLD T 46 CFR 182.20-40 (b)(3).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2021
Resolution: Witnessed proper operation of fuel shutoff over facetime.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 June 2020 Resolved
All distress flares were expired. Provide 03 valid red hand flares and 03 valid orange smoke flares. 46 CFR 117.68
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 June 2020 Resolved
Bilge alarms indicated the incorrect spaces. Either rewire or relabel the bilge alarm panel so that the correct space is identified when a bilge alarm sounds. 46 CFR 119.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2020 Resolved
Replace the bracket for the floating water-light tied to the ring-buoy on the port side of the pilothouse. 46 CFR 117.71(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 2 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 June 2020 Resolved
Make identified bulkhead penetration in machinery space water tight. Wire run from sewage tank space to machinery space needs to be sealed to watertight standards with approved sealant. Penetrations of required watertight decks/bulkheads by any rigid plastic pipe systems are prohibited, except when using an acceptable metallic fitting, welded or otherwise attached to the bulkhead or deck by an accepted method and an acceptable metallic shutoff valve is installed adjacent to the through deck or through bulkhead fitting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 26 August 2020
Resolution: Penetrations repaired, sewage pipe penetration properly fitted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 June 2020 Resolved
Plug identified hole in forward bulkhead of stair tower to machinery space. 46 CFR 116.415
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 29 July 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 June 2020 Resolved
Install a chain on the hatch entering the Lazzarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 2 July 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 June 2020 Resolved
Remove debris in containment on aft deck. 46 CFR 147.45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 2 July 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 June 2020 Resolved
Clean port side steering pump hydraulic containment. 46 CFR 147.45
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 29 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 June 2020 Resolved
Install proper lighting fixture guards for emergency lighting in liquor locker. 46 CFR 120.410
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2020
Resolved 30 July 2020
Resolution: Guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2020 Resolved
Open air receivers for internal inspection by USCG marine inspectors. 46 CFR 61.10-5
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 2 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 June 2020 Resolved
Replace the aft air receiver pressure gauge. 46 CFR 54.15-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 29 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020 Resolved
Remove dead end wiring under bridge in battery compartment and properly mount loose wiring. 46 CFR 111.60-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2020
Resolved 29 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 March 2020 Resolved
Remove Port Propeller and aft section of Tailshaft for inspection.
Action required: 705 - Other - as specified
Resolved 18 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 March 2020 Resolved
Conduct Dye Penetrant testing of all Port shaft coupling bolts and keys.
Action required: 705 - Other - as specified
Resolved 9 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2020 Resolved
Vessel suffered a loss of steering due to an unforseen failure. Make proper repairs and provide technician report indicating cause of failure, repairs completed and specific testing conducted to demonstrate unit is returned to proper operating conditions. Vessel is restricted from carrying passengers until deficiency is rectified. 46 CFR 58.25
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 November 2019 Resolved
Repair all leaks in the steering hydrulic system. Until the leaks are corrected, rounds of the hydrualic steering system must be performed hourly while the vessel is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2019
Resolved 4 December 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 November 2019 Resolved
Repair structural fire protection in machinery spaces as identified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2019
Resolved 4 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 November 2019 Resolved
Replace port and starboard rudder bearing races.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 October 2019 Resolved
Repair bulkhead seals and deck penetrations as identified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 November 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019 Resolved
Complete satisfactory sea trials in the presence of a CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 June 2019 Resolved
Provide durable marking of at least 1" numbers and letters for upper deck passengers permitted IAW COI and currently stability letter. Ensure marking is posted at the entranceway to that deck.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 27 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 June 2019 Resolved
Found one 50 person IBA expired for servicing. Vessel is restricted to 450 persons for limited coast wise route. Properly service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2019
Resolution: Vessel was outfitted with rental 50 person IBA
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 25 June 2019 Resolved
Replace 02 shackles on 02 IBA's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 June 2019 Resolved
Provide appendices for current alternate security plan.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 21 August 2019
Resolution: Vessel's ASP included all appendixes.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 25 June 2019 Resolved
Prove proper operation on 04 fire doors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2019
Resolved 25 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019 Resolved
Provide retro-reflective material on 05 adult sized life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 25 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2019 Resolved
Properly label #4 fire station.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2019 Resolved
Repair damaged coolant hoses on port MDE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 June 2019
Resolved 11 June 2019
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 March 2018 Resolved
Prove proper operation of F/O shutoff valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2018
Resolution: Overhauled valve and linkage, operationally tested SAT.
Construction/Loadline › Structures › Scuttle
Issued 27 March 2018 Resolved
Install captive chain on steering gear space hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Chain installed.
Stability › Weathertight Integrity › General
Issued 27 March 2018 Resolved
Replace broken window on starboard side main deck bow compartment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2018
Resolution: Repaired using 2 layers of plexy-glass. New glass window ordered.
Stability › Weathertight Integrity › General
Issued 27 March 2018 Resolved
Install approved window in accordance with vessel plans.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Window installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 27 March 2018 Resolved
Properly install door in frame on main deck bow compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2018
Resolved 11 July 2018
Resolution: Door replaced in kind.
Fire Fighting › Fire Hydrants › Material
Issued 27 March 2018 Resolved
Install handle on valve at fire station # 4.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Handle installed.
Lifesaving › Inflatable Buoyant Apparatus › Serviceable
Issued 27 March 2018 Resolved
Replace expired Hydrostatic Release Unit (HRU) on IBA Ser# L020300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: HRU Replaced.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 27 March 2018 Resolved
Properly install HRU for the following IBAs Ser# 11013910, P3725, P3724 by etching in accordance with manufacturer's instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: HRUs installed correctly.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 27 March 2018 Resolved
Post Employee Assistance Program hotline numbers in crew space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: EAP posted.
Fire Fighting › Fire Hoses › Condition
Issued 27 March 2018 Resolved
Replace fire hose at station #3.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 March 2018
Resolution: Replaced with new hose on the spot.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 March 2018 Resolved
Install non-conductive mats or grating on deck in front of each switchboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Mats installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Engine room: Properly install cable entering light switch box located at STBD side of engine room door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Switch removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Engine room: Properly hang/secure wires IVO starboard side FWD BLKHD under electrical panels.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Wires properly supported.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Properly hang/secure engine control wire bundles above each engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Wires properly supported.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 27 March 2018 Resolved
Install missing fire insulation on overhead where required and missing. Primarily engine room and galley space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2018
Resolved 11 July 2018
Resolution: Structural insulation installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 March 2018 Resolved
STBD main engine raw water discharge pipe/hose: Renew section of rubber hose approved J1942 hose and fittings; additionally, the hose section shall be less than 30 inches. In the interim double hose clamp hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Hose replaced w/ hard pipe.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 March 2018 Resolved
STBD shaft safety guard: Configure guard to provide complete protection from rotating shaft.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Guard installed.
Construction/Loadline › Structures › Air Pipe
Issued 27 March 2018 Resolved
Port reduction gear is missing a ventilation grating: renew with proper grating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2018
Resolved 11 July 2018
Resolution: Replacement grating installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Galley space: Repair broke wire hanger bracket (broke weld at blkhd.)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Bracket replaced.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 27 March 2018 Resolved
Galley range hood vent ducting needs thorough cleaning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Vent cleaned.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 March 2018 Resolved
There is an electric bilge pump, located in STBD aft galley space, that needs to be permanently wired utilizing proper marine cable/wire.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Pump removed.
Navigation › Piloting/Steering › Steering Magnetic Compass
Issued 27 March 2018 Resolved
Properly install compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 30 April 2018
Resolution: Light properly installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 June 2017 Resolved
Remove oven in snack bar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 27 June 2017
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 June 2017 Resolved
Improve general welfare in E/R. 46 CFR 115.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 27 June 2017 Resolved
Replace missing valve on E/R fuel manifold.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Accommodation/Occupational Safety › Heating › Electric Air Heating Equipment
Issued 27 June 2017 Resolved
Remove (2) two space heaters from bridge, and all other spaces. 46 CFR 121.200.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 27 June 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 June 2017 Resolved
Cover exposed GFCI in pantry.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 27 June 2017 Resolved
Replace light guards in pantry.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 June 2017 Resolved
Label mission circuits in snack bar.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 June 2017 Resolved
Replace missiong auto closure on door leading to E/R.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 June 2017 Resolved
Properly mount fire extinguisher in bar area.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 June 2017 Resolved
Replace line connecting lifering light to lifering.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 June 2017 Resolved
Prove proper operation of port MDE coolant system.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 27 June 2017 Resolved
Replace missing IBA. Vessel restricted to 450 total people on limited coastwise route.
Action required: 705 - Other - as specified
Due 11 July 2017
Resolved 12 July 2017
Engineering › Generator (propulsion/auxiliary-electric) › Interlock Circuitry
Issued 4 August 2016 Resolved
Make repairs and demonstrate proper operation of the vessel generators to the satisfaction of the attending marine inspector.Generator operation failed due to cooling system sensor failing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 September 2016
Resolved 4 September 2016
Resolution: New sensor installed. Generator sensor relplaced. Attended vessel to ensure proper operation.
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 29 June 2016 Resolved
Provide speed and direction of rotation instrumentation for both prop shafts
Action required: 705 - Other - as specified
Due 20 August 2016
Resolved 11 October 2016
Resolution: Installation verified.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 29 June 2016 Resolved
Provide alarm for primary loss of power to propulsion controls
Action required: 705 - Other - as specified
Due 20 August 2016
Resolved 6 December 2016
Resolution: Alarm installed satisfactorily.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 29 June 2016 Resolved
Provide visual and audible alarm for propulsion control system failure on the bridge and machinery space
Action required: 705 - Other - as specified
Due 20 August 2016
Resolved 6 December 2016
Resolution: Alarm installed satisfactorily.
Electrical › Electrical Distribution System (service) › Fuse
Issued 29 June 2016 Resolved
Provide proper fuses in propulsion control system
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 July 2016
Resolution: Cartridge fuses now installed
Fire Fighting › Fire Pumps › Pressure
Issued 29 June 2016 Resolved
Provide proper gauge at fire pump
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 July 2016
Resolution: Operational gauge installed at fire pump
Lifesaving › Inflatable Buoyant Apparatus › Capacity
Issued 29 June 2016 Resolved
Vsl restricted to no more than 450 pax while operating on a limited coastwise voyage.
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Sixth raft has been provided
Electrical › Electric Generation Source (service) › Power Requirement
Issued 13 April 2016 Resolved
Provide load analysis for electrical plant to include a voltage drop analysis.
Action required: 705 - Other - as specified
Resolved 29 June 2016
Resolution: Load analysis submitted.
Stability › Watertight Integrity › General
Issued 31 March 2016 Resolved
Crop and renew damaged bow section and associated framing. Submit repair plan to this office.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2016
Resolved 15 June 2016
Resolution: Attended vessel and verified proper repair of bow section that was damaged due to allision.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 31 March 2016 Resolved
Prove proper operation of both engine/transmission throttle controllers and submit tech report to this office.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Attended vessel and verified operation. Issued different 835.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 31 March 2016 Resolved
Prove proper operation of port dripless packing gland.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Dripless packing gland operational
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 31 March 2016 Resolved
Repair leak and prove proper operation of port side transmission.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Both transmissions rebuilt and operational
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 31 March 2016 Resolved
Prove all engine mounting bolts are of specified strength.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: New engine mount bolts installed
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 31 March 2016 Resolved
Prove proper operatoin of engine shutdown from all conning stations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: ESD operational from all conning stations
Engineering › Steering Gear System › Rudder
Issued 31 March 2016 Resolved
Repair water leak on stbd rudder post.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Water leak repaired

Casualty record · 15

11 March 2006Routine · role: Involved in a Marine Casualty · activity 2603035
1 August 2007Routine · role: Involved in a Marine Casualty · activity 3015179
17 February 2011Routine · role: Involved in a Marine Casualty · activity 3967298
11 March 2011Routine · role: Involved in a Marine Casualty · activity 3978896
13 April 2012Routine · role: Involved in a Marine Casualty · activity 4291341
15 April 2012Routine · role: Involved in a Marine Casualty · activity 4291606
22 April 2012Routine · role: Involved in a Marine Casualty · activity 4293654
20 December 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4774681
4 April 2016Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 8 injured · activity 5847010
4 September 2016Routine · role: Involved in a Marine Casualty · activity 6004523
27 November 2022Routine · role: Involved in a Marine Casualty · activity 7609320
12 May 2023Routine · role: Involved in a Marine Casualty · activity 7701646
15 May 2023Routine · role: Involved in a Marine Casualty · activity 7713133
6 September 2024Routine · role: Involved in a Marine Casualty · activity 8026893
1 July 2025Routine · role: Involved in a Marine Casualty · activity 8178172
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.