INSPIRATION HORNBLOWER

INSPIRATION HORNBLOWER is a 1992 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 2016, most recently in March 2026, along with 206 deficiencies — 2 with no resolution recorded — and 7 casualty investigations between 2010 and 2022.

Records from 2010 to 2026. Most recent: inspection, 18 March 2026.

Built
1992
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC6807
374158
Flag
UNITED STATES
Maury page id
psix-374158

Documentation record

Registered dimensions (L × B × D)182.8 ft × 66.0 ft × 11.0 ft
Registered tonnagegross 1,136 / net 773
ITC dimensions (L × B × D)182.8 ft × 66.0 ft × 11.0 ft
ITC tonnagegross 2,944 / net 883
BuilderATLANTIC MARINE INC · JACKSONVILLE, FL, UNITED STATES · built 1992
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 22 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it883 - Convention (Subpart B), Net Ton
773 - Regulatory (Subpart C or D), Net Ton
2944 - Convention (Subpart B), Gross Ton
1136 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ADVENTURE HORNBLOWER Passenger (Inspected) · MISLE 399093 · 27 November 2022 · activity 7609320

Inspection history · 61

18 March 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8328311
12 November 2025 In-Service Inspection · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8255576
12 June 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8157787
28 April 2025 Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8124083
16 January 2025 Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8067115
23 October 2024 Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023760
14 July 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7959056
13 June 2024 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7930240
13 March 2024 In-Service Inspection · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7878375
10 January 2024 Administrative Inspection · Internal Structural Exam · Underwater Inspection in lieu of Drydock · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7848531
13 December 2023 Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7838789
13 September 2023 Deficiency Check · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7791092
6 September 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7786908
18 August 2023 Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7751237
25 July 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7752659
21 July 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7748512
15 June 2023 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7713654
6 May 2023 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7683578
15 April 2023 Examination of Repairs · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7673185
15 March 2023 Re-Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7652281
14 December 2022 Re-Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609317
27 November 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7609320
26 November 2022 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7600769
19 October 2022 Excursion Permit · Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7580380
15 September 2022 Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7528304
4 August 2022 Administrative Inspection · Excursion Permit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7528499
3 July 2022 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7558844
15 June 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7476206
28 April 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7440225
7 December 2021 Deficiency Check · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7363842
20 September 2021 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7268779
7 June 2021 COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7224931
29 April 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185829
29 December 2020 Deficiency Check · Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7109127
23 December 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7115703
4 December 2020 Examination of Repairs · Deficiency Check · Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7106251
15 November 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7096783
18 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6975033
18 March 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6927440
19 September 2019 Periodic Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6815707
19 March 2019 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6641848
4 February 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6619712
11 September 2018 MTSA Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6537898
23 July 2018 Administrative Inspection · Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6511134
15 June 2018 Load Line/Change of Employment
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6449413
19 April 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6395667
19 March 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6374328
17 December 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6326319
11 December 2017 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6334885
11 September 2017 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6264349
29 August 2017 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6254561
25 August 2017 Administrative Inspection · Construction Oversight · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6251592
14 August 2017 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6240364
8 August 2017 Re-Inspection · Administrative Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6234268
9 June 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6161799
31 January 2017 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6082392
24 January 2017 Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6074330
28 December 2016 Excursion Permit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6063152
7 June 2016 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5898990
8 March 2016 Periodic Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5829661
6 January 2016 In-Service Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5792386

Deficiency record · 206

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 March 2026 No resolution recorded
Vessels that operate in salt water must undergo two drydock examinations within five years. Vessels five year anniversary of the second drydock was February 28, 2026. Vessel's COI is not longer valid.
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 November 2025 Resolved
The bilge suction in the air conditioning compartment was unable to pump due to excess scale built up on the bottom plating. De-scale area and prove proper operation of the A/C compartment bilge suction. 46 CFR 56.50-50
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2025
Resolution: MI attended vessel and witness operationl test. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2025 Resolved
The port main engine diesel fuel supply and return piping was found to be unsupported and prone to vibration. Properly clamp fuel piping lines to prevent movement. 46 CFR 56.50-75
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2025
Resolution: MI attended vessel and verified pipes was properly secured. ALL SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 12 November 2025 Resolved
All crew must have a valid medical card/certificate onboard. One mariner identified to the Captain and Port Captain was missing his medical certificate. Prior to fullfilling a required position as indicated on the COI, all mariners are to have a current medical certificate.
Action required: 705 - Other - as specified
Resolved 12 November 2025
Resolution: Vessel removed mariner from operations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 12 June 2025 Resolved
If a main transverse watertight bulkhead is penetrated, the penetration  must be made watertight.  The watertight bulkhead to the Lazarette had multiple openings on the starboard side where cabling was removed leaving a 3 inch hole in two areas. Additionally, a broken pipe was found in the steering gear room, remove in the Laz/steering gear room and make watertight. Make the bulkhead watertight.  46 CFR 72.30-1   /  46 CFR 171.111
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2025
Resolution: Received picture of bulkheads being made watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2025 Resolved
Remove dead shore power cables (2) in steering gear room.  46 CFR 70.25-1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2025
Resolution: Recieved picture of shore power cables being removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2025 No resolution recorded
Vessel’s key control system has not yet been fully implemented. Fully implement the Master [name withheld], including training all affected staff and crew. To be rectified by next quarterly inspection. Cite: 46 U.S.C. 3106
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 June 2025 Resolved
All vessels shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. It was discovered that the bilge pumping plant was uncapable of dewatering the steering gear room. Maintenance should be conducted ensuring that the entire bilge system works at all times as intended. Test system in the presence of Marine inspector once fully operational. 46CFR56.50–50 (a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 June 2025
Resolution: Witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 April 2025 Resolved
Each rescue boat must be marked with type II retro-reflective material to meet IMO Resolution A.658(16). Retro tape faded and worn on both rescue boats. Provide new retro tape on both rescue boats. 46 CFR 199.176(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2025
Resolved 1 May 2025
Resolution: Retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 April 2025 Resolved
The proper condition and operation of the rescue boat including engines. Starboard rescue boat fuel tank cracked. Provide new gasoline fuel tank prior to operating starboard rescue boat.
Action required: 705 - Other - as specified
Resolved 1 May 2025
Resolution: Fuel tank provided.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 January 2025 Resolved
Double swing doors, where permitted, may have a maximum clearance of 1/8 inch at tops, sides, and between the doors. Gap between Fire Screen Doors and on side and between doors greater than 1/8 inch. Provide gap less than 1/8th inch or provide doorstop to overlap the gap. 46 CFR 72.05-25(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 27 February 2025
Resolution: New metal bar added to remove gap.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 January 2025 Resolved
All fire screen doors shall be numbered conspicuously in not less than 3/8 inch letters and figures. Fire screen doors on 0-2 deck missing marking. Provide marking for 0-2 deck fire screen doors. 46 CFR 78.47-35
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 1 February 2025
Resolution: Doors marked.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 16 January 2025 Resolved
Vessels of 1,000 gross tons shall have a permanently exhibited for the guidance or the officer in charge of the vessel the general arrangement plans showing for each deck the various sections enclosed by fire-resisting bulkheads. General arrangement plan missing fire screen doors on 0-2 deck. Provide updated general arrangement plan with all FSD's on 0-2 deck. 46 CFR 78.45-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 February 2025
Resolved 27 February 2025
Resolution: Fire control plan updated.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 October 2024 Resolved
Three (03) of the starboard IBAs (450 person capacity) were found to have expired hydrostatic releases. Replace the hydrostatic releases with ones in compliance with 46 CFR 199.130(c)(7). Vessel's total person count is reduced by 450 people until deficiency is rectified. Cites: 46 CFR 71.15-1, 46 CFR 199.130(c)(7), 46 CFR 199.630(g)
Action required: 705 - Other - as specified
Resolved 30 October 2024
Resolution: New hydros were installed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 October 2024 Resolved
An abandonship drill and fire drill must be conducted on eaach passenger vessel at least weekly. Vessels logs showed that drills were being conducted on roughly a monthly basis. Conduct an abandonship drill and fire drill weekly, or prior to carrying passengers if the vessels has not been operating for over a week. Cites: 46 CFR 71.15-1, 46 CFR 199.250
Action required: 10 - Deficiency Rectified
Resolved 23 October 2024
Resolution: Vsl master was taught the drill requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2024
Resolved 30 December 2024
Resolution: Plan written and reviewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 14 July 2024 Resolved
Emergency generator failed to take the load while vessel's crew was preforming pre-underway checks. Prove proper operation of emergency generator prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 14 July 2024
Resolution: Repairs were made and satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 June 2024 Resolved
Fire door #6 did not latch when all fire doors were released. Adjust settings in fire door to ensure all latch. Until fire door is repaired ensure crew is aware of the issue and designate someone to ensure the door latches as part of their WQSB until it is repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 20 June 2024
Resolution: Received a video of the door latching appropriately.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 March 2024 Resolved
The emergency generator fire screen door was found wasted on the bottom / inner edge. Make temporary repairs to the door and submit plans for a permanent repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2024
Resolved 13 June 2024
Resolution: Fire screen door was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2024 Resolved
Vessel's (air) pressure vessels are not fitted with inspection ports and cannot be adequately internally inspected. Vessel is being placed on a twice in five year schedule to conduct a 1.25 MAWP hydrostatic test. Preform test within 30 days with CG inspector attendance or provide commercial hydro certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2024
Resolved 13 June 2024
Resolution: Witnessed satisfactory hydro test of both air receivers.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2024 Resolved
PSTP's item 2.6 requires a "rpm measuring device" to complete. Provide vessel with an adequate measuring device to complete item 2.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2024
Resolved 13 June 2024
Resolution: RPM measuring device was provided
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2024 Resolved
Engine room ventilation shut-down switch in the wheelhouse was found to be inoperable. Make repairs and prove proper operation of the the vent securing switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2024
Resolved 13 June 2024
Resolution: Remote switch was repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 March 2024 Resolved
The thruster prime mover engine's alternator was found missing a mounting bolt. Provide adequate bolt. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 13 March 2024
Resolution: Bolt was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 March 2024 Resolved
Electrical outlet in stairwell to engine room was found with unjacketed wires. Make repairs to outlet. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 13 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 March 2024 Resolved
Vessel has installed a Fire Detection panel that does not have USCG Type Approval. Vessel allowed to operate with interim panel as a result of satisfactory testing until MSC approves new installation plans and type approved panel is installed. Follow up prior to end of May on status of approval and subsequent installation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 May 2024
Resolved 13 June 2024
Resolution: Cleared during COI inspection, please see activity 7930240
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 January 2024 Resolved
Repair/replace the damaged door on the starboard side of the pilot house. To be completed by 29 February 2024. Cite: 46 CFR 72.30-1 & 46 CFR 171.122(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 April 2024
Resolution: A new door was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 January 2024 Resolved
Replace the identified cracked window on the second deck after on the starboard side. To be completed by 29 February 2024. Cite: 46 CFR 72.30-1 & 46 CFR 171.122(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 April 2024
Resolution: A new window was installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 10 January 2024 Resolved
The deck frames IWO emergency fire pump identified with chalk markings found to be wasted. Crop and renew to satisfaction of attending USCG marine inspectors. To be completed by 29 February 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 April 2024
Resolution: The frames were replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 January 2024 Resolved
Repair/replace the damaged door on the port side of the pilot house. To be completed by 29 February 2024. Cites: 46 CFR 72.30-1 & 46 CFR 171.122(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2024
Resolved 9 April 2024
Resolution: The door was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 January 2024 Resolved
All class I watertight bulkhead doors below the main deck failed chalk testing. Adjust/repair class I watertight doors and conduct a new chalk test in the presence of USCG marine inspector(s). Cites: 46 CFR 72.30 & 46 CFR 170.270(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 9 April 2024
Resolution: Door gaskets and hinge pins were replaced. Doors passed a new chalk test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 September 2023 Resolved
Structural Fire protection found to be missing IWO engine room above main entrance door.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 13 October 2023
Resolution: Installed new insolation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 September 2023 Resolved
Structural Fire Protection found to be missing IWO engine room above port generator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 13 October 2023
Resolution: Installed new installation
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 September 2023 Resolved
Structural Fire Protection found to be missing IWO water chiller room above stbd diesel tank.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 13 October 2023
Resolution: Installed new installation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2023 Resolved
White smoke was detected in an overhead space near the engine room. Identify source of smoke, determine extent of damage and submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2023
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 June 2023 Resolved
The steel overhead of the emergency generator compartment was found with a holed, in vicinity of welded electrical stuffing tube. Re-weld area and make compartment vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 30 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2023 Resolved
The emergency generator starting batteries were found un-secured in their containment boxes, properly secured batteries to prevent shifting.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 20 June 2023
Resolution: Received photos of the batteries with blocking holding them in place.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2023 Resolved
Minimize fire hazards insofar as is reasonable and practicable. In the machine shop, store flammable chemicals in fireproof cabinets, remove wasted leaking can of paint thinner located in machine shop from the ship and strap down loose oxygen and argon bottles.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2023
Resolved 15 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2023 Resolved
Tests must be conducted at periodic intervals that vital systems and safety features continue to operate in a safe, reliable manner. Repair or replace emergency fire pump shaft packing to correct flooding.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 13 October 2023
Resolution: Replaced emergency fire pump
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 June 2023 Resolved
Bridge to Bridge and Radio Safety Certificates expired on 12JUN2023. Must show proof of renewal to USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 30 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 May 2023 Resolved
Vessel lost propulsion of bow thruster while underway with passengers. Repair bow thruster or provide mitigation strategy to maintain maneuverability.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2023
Resolution: Witnessed satisfactory test of bow thruster post repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 March 2023 Resolved
Lifeboat and rescue boat release gear must be serviced at the following intervals: -thorough examination every year -operationally tested under a load of 1.1 times the total mass of the boat once every five (05) years. -falls must be end for end at intervals of thirty (30) months and renewed at intervals of five (05) years. Last records that were available for the servicing of the rescue boat launching appliances were 15MAR18. Must provide more recent records of servicing or conduct the required servicing for rescue boat launching appliances.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 15 June 2023
Resolution: Meeting with Owner Rep to have lifesaving appliances inspection aa part of SMS. Vessel in process of changing falls.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Entry stairwell to engine room; four (04) feet light fixture missing diffuser cover; light bulbs exposed. Must install light fixture diffuser to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 12 April 2023
Resolution: Verified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Galley stove electrical panel single receptacle outlet cover broken. Must replace cover to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 12 April 2023
Resolution: Verified by [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 March 2023 Resolved
Four (04) inch weather deck drain pipe wasted at elbow joint. Must repair/replace to the satisfaction of the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 12 April 2023
Resolution: VErified by [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2023 Resolved
Top deck at AFT STBD quarter weather deck light fixture full of water; Must repair/replace to the satisfaction of the CG Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 15 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 March 2023 Resolved
Engine room FWD bilge alarm unit inoperable. Must repair/replace to the satisfaction of the CG Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 15 March 2023
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 March 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection (2) Perform the duties and functions of patrolmen or watchmen or (3) Are specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies. Company DAPI policies and proof of enrollment of vessel crew members in a consortium not available for inspection. Must provide DAPI letter of company enrollment and list of vessel employees to the CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2023
Resolved 15 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 December 2022 Resolved
PORT side rescue boat battery found not properly secured from movement, and contained within its storage container. Provide securing means to battery storage unit. Send Picture of corrected to [email withheld]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 19 December 2022
Resolution: Received picture of corrected deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2022 Resolved
Second deck weather deck light fixture in overhead between decks at stern area; light bulb cover/ diffuser cracked. Repair / replace and send picture to [email withheld]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 20 January 2023
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 26 November 2022 Resolved
Cradle of rescue boat was damaged and must be replaced to adequately allow the rescue boat to deply and be recovered.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 December 2022
Resolution: Verified repairs on quarterly inspection. [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 15 September 2022 Resolved
03 IBAs (300 person capacity total) are past due for servicing. Remove the expired IBAs from the vessel until servicing is completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2022
Resolved 14 December 2022
Resolution: Verified during quarterly exam in December 2022. [name withheld]
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 September 2022 Resolved
An abandon-ship drill and fire drill must be conducted at least weekly. Conduct these drills weekly and properly log with the names of all crew members in attendance. To be completed by next quarterly exam.
Action required: 705 - Other - as specified
Resolved 14 December 2022
Resolution: Verified during quarterly exam December 2022...[name withheld]
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 September 2022 Resolved
Remove paint from all dog wedges and adjust dogs on all watertight doors. Ensure watertight doors are closed at all times when underway, except when being actively being passed through.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 3 October 2022
Resolution: Paint was removed and dogs were loosened.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 15 September 2022 Resolved
Repair broken beam for cradle of portside rescue boat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2022
Resolved 3 October 2022
Resolution: Beam was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 September 2022 Resolved
The lifebuoy located on the starboard bridge wing has a permanently attached self-igniting light. Outfit the attaching line for the self-igniting light with a clip or similar device to allow crew to rapidly detach the light from the lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 3 October 2022
Resolution: A hook was spliced at the end of the line to allow detachment of the light from the life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 September 2022 Resolved
Vessel had 03 expired orange smoke flares. Replace the expired flares.
Action required: 10 - Deficiency Rectified
Resolved 15 September 2022
Resolution: Corrected on the spot by acquiring additional red hand flares.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2022 Resolved
Emergency generator not operational due to electrical short in exciter unit. Repair / replace. Provide alternate means for emergency power source to support all emergency vital loads necessary for proper and safe operations. Provide spec sheet data of alternate power source to [email withheld]. Temporary power source will require USCG attendance for load test of vital equipment.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2022
Resolved 29 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Black water tank void space; overhead electrical J-box not properly mounted and outer cable jacket worn. Remount box and repair cable jacketing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 21 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Grey water void space; tank transducer unit not properly mounted. Remount unit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 21 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Grey water void space; overhead electrical J-box not properly sealed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 21 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Fresh water tank void space; electrical cable in overhead dead-ended. Repair or remove cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 21 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Grey water void space; overhead electrical cable dead ended. repair or remove cable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 21 June 2022
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Engine room fire pump motor controller stop button indicator missing. Repair.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2022
Resolved 14 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2022 Resolved
Main SWBD generator synchro switch inop. Repair replace. Port Engineer continues to update - part had to be custom manufactured and is pending.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2022 Resolved
Persons designated by company shall be familiar with periodic safety test procedures (PSTP)and the function- ality of operations, controls, alarms, safety features and interlocks prior to conducting test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 December 2021 Resolved
Repair port side steering hydraulic ram found substantially leaking when extended in hard over to port.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 13 January 2022
Resolution: Tested in presence of attending MI.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2021 Resolved
On-board training, musters and drills must be in accordance with sub-chapter W Title 46 CFR. Every crew member must participate in one fire drill every month. Last fire drill recorded on 29AUG2021. Must conduct fire drill in presence of CG Marine Inspectors prior to getting underway with passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Observed successful fire drill and deployment of rescue boat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 December 2021 Resolved
It shall be the duty of the owner/master/person in charge to see that the vessel's firefighting equipment is at all times ready for use. Three air bottles for the firefighting ensembles located on Deck 01 had around 10 minutes of air. Must replace or refill bottles prior to getting underway with passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Observed during drill...[name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2021 Resolved
Must mark life jacket container located adjacent to rescue boats in accordance with 46 CFR sub-chapter W.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 27 January 2022
Resolution: Pictures received via e-mail.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2021 Resolved
Each vessel must be provided with a sound-powered telephone to communicate with the bridge from the steering gear. Repair sound powered phone squaker handle in steering gear room. Unit could not make calls out to Engine Control Room or Bridge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 13 January 2022
Resolution: Tested by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 December 2021 Resolved
Each switch must meet Article 404 of NFPA NEC. Provide closure on power on/off knife switch box on stbd bulkhead over work bench in E/R found with opening on aft side.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 13 January 2022
Resolution: Cleared by attending MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 December 2021 Resolved
If a main transverse watertight bulkhead is penetrated, it must be made watertight. Properly pack the following cable bulkhead penetrations with approved materials:Forward bulkhead on STBD side E/R, Aft bulkhead STBD side E/R, and Aft bulkhead portside E/R have cable transits with openings from removed and or changed wiring. Seal E/R bulkhead cable penetrations with an approved material that is rated for the A-0 fire boundary outlined on the vessel’s fire control plan.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 13 January 2022
Resolution: Cleared by attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 June 2021 Resolved
Total IBA's onboard with aggregate capacity of 306 persons. Total persons allowed reduced to a total of 455 until additional IBA's brought back onboard and installation is verified by a USCG Marine Inspector.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 25 June 2021
Resolution: Owner rep [name withheld] sent photos of proper installation of missing IBA's as well as annual servicing reports.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2021 Resolved
Replace the 6 deteriorated ring buoys under approval series 160.150.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 21 July 2021
Resolution: Verified 06 ring buoys with proper approval onboard and installed. - [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2021 Resolved
Seal aft bulkhead cable penetration in the bridge with an approved material that is rated for the fire boundary identified per the vessel's fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: MCT's filled with with fire retardent sealant. -[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2021 Resolved
Seal STBD bulkhead cable penetration in bow thruster space with an approved material that is rated for the fire boundary outlined on the vessel's fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: Penetrations were sealed with fire stop.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 June 2021 Resolved
Evaluate and rectify missing A60 deck fire insulation on overhead in vicinity of FWD storage locker in accordance with vessel's fire control plan. Ensure small section of A60 insulation is corrected during upcoming drydock period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2021
Resolved 12 November 2021
Resolution: Ensure small section of A60 insulation is corrected during upcoming drydock period. Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 June 2021 Resolved
Move spill kits located on fantail to a location that does not impeded the access to manual fire dampers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 21 July 2021
Resolution: Verified spill kits did not impede damper operation with new stowage location. - [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 June 2021 Resolved
Replace damaged heat detector in EDG space. Detector was damaged during testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 21 July 2021
Resolution: Detector was replaced in-kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2021 Resolved
A temporary oil transfer pump is wired with a spliced household lightswitch and an extension cord and is mounted to the bulkhead in the engineroom. The pump must be removed from the vessel or permanently wired in accordance with subchapter J.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: The pump was removed from the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2021 Resolved
All sight glasses in the engine room for the clean oil, dirty oil, and fuel oil tanks are currently fitted with non-heat-resistant tubing and valves that do not automatically close. Each sight glass must be fitted with automatically closing valves and heat resistant tubing during next dry dock. Until this deficiency is rectified, the lower valve for each sight glass must be kept closed except when the tank levels are being checked. To be corrected during next dry dock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2021
Resolved 13 January 2022
Resolution: Awaiting 01 sight glass which broke during installation during DDX. Final sight glass installed and inspectec by attending MI.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 June 2021 Resolved
The manual pull station outside the EDG space has a placard that was painted over all white. The placard must be repaired or renewed to show the required markings in red on a contrasting background.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: New placards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021 Resolved
Repair oil leak on STBD SSDG turbo and renew the oil soaked lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: A bolt was found loose on the oil line under the turbo, bolt was tightened and tested.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 June 2021 Resolved
Fresh water pressure tank must be fitted with a pressure relief valve of at least 1" in diameter that is set to relieve below the max allowable working pressure (MAWP) of the tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 12 November 2021
Resolution: Verify 1" diameter relief valve is installed during upcoming dry dock period. system was not delivered with one nore has it operated with since install. -[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 June 2021 Resolved
The two fresh water pressure tanks must be hydrostatically tested to 1.25 times the maximum allowable working pressure (MAWP) twice within any five year period. In addition, the safety relief valves on the pressure vessels must be tested at each inspection for certification. Schedule a time w/in 30 days for a Marine Inspector to witness hydrostatic tests of the pressure vessels and a test of the safety relief valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: Determined hydrostatic test not needed provided 1" relief device is installed. [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021 Resolved
The EDG High Jacket Water Temp alarm does not operate. Make repairs and retest.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: New heat sensor was installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2021 Resolved
The reverse power relay does not operate on #2 SSDG. Prior to paralelling generators, make repairs and retest to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 7 December 2021
Resolution: Witnessed proper parralelling of both generators from #1-#2 & from #2-#1.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021 Resolved
Update electrical panel circuit directories in the engine room space, Refer distillate space and Freshwater and greywater space.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: All panels were properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 June 2021 Resolved
Freshwater and greywater space overhead area missing 12" x 12" insulation shielding. Ensure missing area replaced prior to completion of credit dry dock exam.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 July 2021
Resolved 12 November 2021
Resolution: Ensure missing area replaced prior to completion of credit dry dock exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021 Resolved
Verify all Engineroom, forward refer space and freshwater / greywater electrical panel and overhead j-box cable penetrations are properly sealed when not in use.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: All electrical box openings were properly plugged.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 June 2021 Resolved
IBA's not stowed IAW manufacturers instructions; painter line tied to weak link. Attach painter line to hydrostatic release units on all IBAs IAW manufacturers instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 7 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021 Resolved
Remove or properly terminate various dead end wires identified throughout forward storage locker, workshop, and storage spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 21 July 2021
Resolution: All wires were terminated inside a junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021 Resolved
With the #1 generator supplying the bus, the #2 generator is unable to be paralleled to the #1. Make repairs and prove proper operation on synchroscope circuit and paralleling ability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2021
Resolved 7 December 2021
Resolution: Tested parallelling of both generators and reverse power relays.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2021 Resolved
While on ship's power, vesell's 208V / 112.5KVA transformer ground detection shows a 10 amp ground. Troubleshoot and remove electrical current from vessel's hull.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2021
Resolved 7 December 2021
Resolution: Fault identified on FCU14 for AC Blower. C/E tagged out blower until replacement parts arrive.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 11 February 2021 Resolved
Temp repairs to pinholes in top of sewage tank authorized. Clean sewage tank internals and make available for inspection at next Dry-Dock Exam. Make permanent repairs to holed areas and other areas identified during internal inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 12 November 2021
Resolution: Fully repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 December 2020 Resolved
Repair hole in port MDE exhaust at side shell. Provide repair proposal to Sector San Diego for approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2021
Resolution: All repairs found satisfactory by attending MI.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 December 2020 Resolved
Replace seized bilge alarm sensor in rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2021
Resolution: Bilge alarms tested satisfactory by attending MI.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 December 2020 Resolved
Install audible fire alarm in engine room watch stander space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2021
Resolved 11 February 2021
Resolution: Audible fire alarm installed and tested satisfactory by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 December 2020 Resolved
Install proper electrical matting at emergency generator
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2021
Resolved 11 February 2021
Resolution: ASTM-D178-01 Type II Class 2 Portable Switchboard mat installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 December 2020 Resolved
Prove proper operation of emergency generator meters (Voltage and Amperes).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2021
Resolved 1 March 2021
Resolution: Attending MI tested EDG meters.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 December 2020 Resolved
Tighten loose cable connections on 24V battery switch at E/R fwd bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2021
Resolved 2 February 2021
Resolution: Inspected satisfactory by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2020 Resolved
Repair stbd steering ram leakage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 January 2021
Resolved 11 February 2021
Resolution: Inspected satisfactory by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 December 2020 Resolved
Clean sewage leakage on top of sewage tank and identify source of leakage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 11 February 2021
Resolution: Leaks on top of tank repaired with splash zone.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2020 Resolved
Clean hydraulic fluid leakage under elevator machinery and repair source of leakage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 11 February 2021
Resolution: Tested eleveator and inspected satisfactory by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 December 2020 Resolved
Permanently repair fire pump machinery guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 2 February 2021
Resolution: Inspected satisfactory by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 December 2020 Resolved
Repair switches or remove unused stuffing box sump pumps on port & stbd sides.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 2 February 2021
Resolution: Inspected satisfactory by attending [name withheld] in controllers sealed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 December 2020 Resolved
Properly pack all cable penetrations in machinery space bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 11 February 2021
Resolution: Inspected satisfactory by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 December 2020 Resolved
Label all loads for breakers in distribution panels throughout vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 1 March 2021
Resolution: Spot checked distribution panel labels.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 December 2020 Resolved
Repair the navigation light indicator panel so that it alarms visually and audibly at the failure of each navigation light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2021
Resolved 11 February 2021
Resolution: Tested/inspected satisfactory by attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 December 2020 Resolved
All automatically or remotely controlled or monitored vital systems addressed by 46 CFR Part 62 must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features and interlocks. Test procedures must be submitted to the Coast Guard for approval. Resubmit revised PSTP's within 30 days to MSC to satisfy comments in the Returned for Revision letter E2-2004006. PSTP's to be tested to satisfaction of attending MI upon receipt of follow-up MSC letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2021
Resolved 13 March 2024
Resolution: PSTP's were submitted and approved by MSC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 November 2020 Resolved
Port diesel generator was atomizing fuel oil. Identify and repair the cause of the atomizing fuel oil.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2020
Resolution: Vessel rep emailed statement attesting to the replacement of the O-ring wil manufacture part, and a successful 30 minute load test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2020 Resolved
Prove proper operation of bilge pumping arrangements in engine room, tank room, and bow thruster space. 46 CFR 71.20-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 18 June 2020 Resolved
Repair or renew steering gear low hydraulic fluid sensors for both reservoirs. Prove proper operation of these alarms. 46 CFR 58.25-25(d)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 June 2020 Resolved
A fire hose was found to be un-serviceable. Replace the identified fire hose in kind. 46 CFR 76.10-10(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2020 Resolved
Replace signage for firefighting equipment and stations as needed in kind. 46 CFR 78.47
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2020 Resolved
Remove dead end wiring and clean up wire runs in forepeak space. 46 CFR 70.25-1; 46 CFR 111.60-17
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 June 2020 Resolved
Must place protective cover over light fixture in storage space adjacent to bridge. 46 CFR 111.75-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2020 Resolved
Replace worn/damaged SOLAS escape route stickers on 01 Deck. 46 CFR 78.47
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2020 Resolved
Repair interior door handle of reefer in liquor storage room on 01 Deck or install alarm to bridge on interior of reefer. 46 CFR 72.05-25
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 18 June 2020 Resolved
Re-attach exit sign adjacent to liquor storage room on 01 Deck. 46 CFR 78.47
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 June 2020 Resolved
Evaluate and rectify missing A60 deck fire insulation on overheads on 01 Deck in accordance with Vessel Fire Control Plan. 46 CFR 72.05-15 Def extended to match dry-dock dates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 12 November 2021
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 June 2020 Resolved
Secure Engine Room Office audible alarm to bulkhead. 46 CFR 62.25-20(e)(vii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 18 June 2020 Resolved
Properly store flammable and combustible materials found throughout engine room. 46 CFR 147.45
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 June 2020 Resolved
Replace flame screen on EDG fuel tank vent. 46 CFR 56.50-75(a); 46 CFR 56.50-85(a)(8)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2020 Resolved
Install low start air alarm at remote control starting stations for start air system. 46 CFR 62.35-50 Table
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 18 June 2020 Resolved
Properly reinstall bolts on ventilation intake to engine room. 46CFR 58.01-45
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2020 Resolved
Repair leak on starboard MDE exhaust in steering compartment. 46 CFR 58.10-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 June 2020 Resolved
Properly pack bulkhead penetrations to engineers office and forward engine room bulkhead (watertight). 46 CFR 72.05-10 Tables; 46 CFR 171.111
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Corrected to the satisfaction of the attending MIs
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 18 June 2020 Resolved
Prove proper operation of sound powered phone system. 46CFR 113.30-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2020
Resolved 29 July 2020
Resolution: Tested S/G to E/R, E/R to S/G, S/G to Bridge and E/R Bridge.
01 - Certificates & Documentation › 013 - Documents › Fire safety operational booklet
Issued 19 September 2019 Resolved
Provide servicing reports for fixed fire protection system and portable extinguishers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Service reports provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2019 Resolved
Repair primary port navigation light.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Light was changed out with a new bulb and was tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 September 2019 Resolved
Repair alarm panel for stern light on the navigation bridge.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Electrical connection was fixed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 September 2019 Resolved
Replace broken life ring light aft 01 deck.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Light changed out with new.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 September 2019 Resolved
Replace expired first aid kits in both rescue boats.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 September 2019
Resolution: Replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2019 Resolved
Repair the "not under command" navigation light located on the topside of the navigation bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: MI's attended vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 September 2019 Resolved
Make a weather tight permanent connection for navigation lights on the topside level of the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: MI attended vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 19 September 2019 Resolved
Clean galley exhaust vent screens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 29 July 2020
Resolution: Corrected to satisfaction of attending MI.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 September 2019 Resolved
Renew area of failed structural fire protection in sewage compartment- forward port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: MI attended vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2019 Resolved
Repair lighting in storage behind wheelhouse and properly hard wire permanently installed fan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: MI attended vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 19 September 2019 Resolved
Install means to connect embarkation ladders at each IBA embarkation station and properly store ladders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: Satisfactory connections installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 September 2019 Resolved
Repair corroded stanchion post on forward mast head light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 18 October 2019
Resolution: MI attended vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 March 2019 Resolved
Replace lifebuoy buoyant lifeline on top deck port station IWO E-Gen. Line shall be 100' in length or 2x the stowage height to water line, whichever is greater.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 12 April 2019
Resolution: Line replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2019 Resolved
Properly ground fans under bridge console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 12 April 2019
Resolution: Grounding straps re-installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2019 Resolved
Remove dead-end wires above both fuel tanks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2019
Resolved 9 May 2019
Resolution: Dead-end wires removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 19 March 2019 Resolved
Machinery alarms and automation testing not performed per filed PSTPs. Vsl's PSTP are not approved and were returned for revision by MSC in 2013. Vsl is required to resubmit addressing comments listed in the MSC letter.
Action required: 705 - Other - as specified
Due 19 April 2019
Resolved 17 November 2020
Resolution: PSTP's submitted to MSC.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 November 2018 Resolved
Clad weld the identified pit in the port forepeak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 9 May 2019
Resolution: Welding company was not comfortable cladd welding below water line. Belzona authorize as temp repair until next dry-dock.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 November 2018 Resolved
Determine if the insulation of the overhead on the port side of the steering gear room is structural fire protection (SFP) or not. If it is SFP, repair as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 4 February 2019
Resolution: Determined by MI not as SFP.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 November 2018 Resolved
Provide a lateral view diagram of the vessel's structural fire protection for the bow thruster space and adjacent rake space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2018
Resolved 4 February 2019
Resolution: Verified by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 September 2018 Resolved
Stbd side rescue boat hand crank missing. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: Hand crank replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 September 2018 Resolved
Provide actuation instructions for EDG halon system.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: Activation instructions installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2018 Resolved
Replace valve nuts on fire stations 8, 6 & 12.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: Nuts installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 September 2018 Resolved
Demonstrate proper operation of FSD's #1 & #2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: MI witnessed FSDs properly operate.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 September 2018 Resolved
Adjust rudder angle indicator on bridge for accuaracy (off by >4 deg)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: MI witnessed RAI operate properly.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 11 September 2018 Resolved
Fix selector switch on EDG sound powered phone. Extended for operator to find proper part.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 4 February 2019
Resolution: Selector switch repaired. Tested SAT.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 September 2018 Resolved
Complete vessel's monthly and quarterly records.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 26 October 2018
Resolution: Logbooks properly filled out.
01 - Certificates & Documentation › 012 - Crew Certificates › Cert for personnel on survival craft & rescue boat
Issued 11 September 2018 Resolved
Provide 06 lifeboatmen endorsements to be IAW COI Manning
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 9 May 2019
Resolution: Written IBA training program approved, training conducted, trainees attending were recorded. Lifeboatmen requirement reduced to 04.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 July 2018 Resolved
Crop and renew the identified wasted deck plating in the steering gear space during next out of water dry dock exam.
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Special note added for this def.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 July 2018 Resolved
Provide a final repair proposal for the doubler in the port forepeak to be completed during the next out of water dry dock exam. Complete the repair following its approval by the attending CG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2019
Resolution: Special note added for this def.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 19 March 2018 Resolved
Prove proper operation of port rescue boat
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2018
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 19 March 2018 Resolved
Implement policy to maintain all lifesaving equimpment IAW manufacturers spec and that ensures all equipment is operationally ready at all times.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2018
Resolved 22 March 2018
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 19 March 2018 Resolved
Provide tech to test engine alarms
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Fire Fighting › Fire Pumps › Pressure
Issued 19 March 2018 Resolved
Prove fire pump operates at 50 psi
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2018
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 19 March 2018 Resolved
Provide properly operating echo depth sound or remove existing from service.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 March 2018 Resolved
Repair cracked glass in wheelhouse
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 March 2018 Resolved
Properly mark lifejacket storage
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 19 March 2018 Resolved
Provide current first aid kits for rescue boats
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2018
Electrical › Electric Supply System (service) › Cable
Issued 19 March 2018 Resolved
Remove electrical hazard in E/R companionway
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Engineering › Thrusters › Piping
Issued 19 March 2018 Resolved
Remove male fitting in low pressure line for bow thruster
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 March 2018 Resolved
Label emerg lighting in conference passageway
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Accommodation/Occupational Safety › Ventilation › General
Issued 19 March 2018 Resolved
Renew start stop button and properly label E/R ventilation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Engineering › Compressed Air System (start air) › Compressor
Issued 19 March 2018 Resolved
Prove proper operation of outbaord air compressor and relief valve on UPV
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 March 2018 Resolved
Remove tires from A/C Room
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 19 March 2018 Resolved
Repair hole on top of MSD tank
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Engineering › Feedwater/Condensate Water System › Piping
Issued 19 March 2018 Resolved
Permanently repair grey water piping
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Personnel › Training › Watchkeeping
Issued 19 March 2018 Resolved
Ensure SSO/Captain has unlimited access to all spaces of the vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 19 March 2018 Resolved
Provide man trapped in reefer alarm system that can be operated from inside the refrigerated space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2018 Resolved
Properly wire power supplies for ovens, cash registers, and radios
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2018 Resolved
Protect bare bulbs throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 April 2018
Operations/Management › Vessel Activity › Construction/Repair
Issued 25 August 2017 Resolved
Provide plans for the replacement of the bow thruster engine (Including engine details, exhaust system, engine cooling, engine mount modifications, electrical system, engine control system, fuel system).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 1 September 2017
Resolution: Engine replaced in kind.
Engineering › Thrusters › Motor
Issued 25 August 2017 Resolved
Prove proper operation of replacement bow thruster engine prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 1 September 2017
Resolution: Engine operationally tested, all sat.
Communications › Alarms/Indicators › General Alarm
Issued 9 June 2017 Resolved
Prove operation on aft steering compartment general alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 8 August 2017
Resolution: Alarm tested SAT.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 June 2017 Resolved
Remove jury rigged electrical receptacle on aft engineroom bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 12 July 2017
Resolution: Electrical hard mounted to breaker.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 June 2017 Resolved
Provide proper battery box for 12 volt battery in engineroom
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 12 July 2017
Resolution: Battery box lid provided.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 9 June 2017 Resolved
Replace expired hydrostatic release units for 3 IBAs on starboard side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2017
Resolved 9 June 2017
Resolution: Purchased and installed new HRUs and verified by attending Marine Inspector
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 June 2017 Resolved
Re-label vessel name on port side pilothouse life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 12 July 2017
Resolution: Life reing re labeled.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 June 2017 Resolved
Change lifejacket stowage marking on main deck (96 to 90)
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 12 July 2017
Resolution: Life jacket stowage changed to proper number.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 June 2017 Resolved
Provide proper operation on fire screen doors #2, 5, 6, 8, and upper deck locations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: All doors working as designed.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 9 June 2017 Resolved
Replace unmarked hydrostatic release unit on port side IBA.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2017
Resolution: Replaced HRU and verified correct installation by attending Marine Inspector
Fire Fighting › Means of Escape › Emergency Lighting
Issued 9 June 2017 Resolved
Replace batteries on various exit signs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 16 June 2017
Resolution: New signs installed.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 9 June 2017 Resolved
Provide signage on #1 embarkation station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 12 July 2017
Resolution: Sinage installed at embarkation station.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 9 June 2017 Resolved
Provide non-combustible trash cans and remove plastic trash cans from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 29 November 2017
Resolution: Invoice for 20 non-combustable tash cans provided.
Fire Fighting › Structural - A Class Divisions › Hose Ports
Issued 9 June 2017 Resolved
Repair fire hose port on fire screen door #10
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2017
Resolved 8 August 2017
Resolution: New hose ports installed on the 1st and 2nd deck.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 31 January 2017 Resolved
Make gauges on helm for bow thruster operational.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 15 February 2017
Resolution: Gauges operational.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2017 Resolved
Provide wiring in the bow thruster room with proper supports.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 15 February 2017
Resolution: Wiring supported.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2017 Resolved
Remove all dead end wiring in bow thruster room.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 15 February 2017
Resolution: Dead end wiring removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 January 2017 Resolved
Cap all dead end wiring.
Action required: 705 - Other - as specified
Due 10 February 2017
Resolved 15 February 2017
Resolution: All dead end wiring capped.
Engineering › Thrusters › Motor
Issued 10 June 2016 Resolved
Prove proper operation of bow thruster engine alarm indicator on bridge.
Due 10 July 2016
Resolved 7 July 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 7 June 2016 Resolved
Make proper adjustments/replacement of magnaetic hold back device for fire screen doors on located on upper deck and FSD #2.
Due 10 July 2016
Resolved 24 January 2017
Resolution: Operationally test fire doors sat
Fire Fighting › Means of Escape › Doorways
Issued 7 June 2016 Resolved
Relocate/remove security chain on STBD side upper deck. (Cannot be used as a hold back on FSD.)
Due 10 July 2016
Resolved 7 July 2016
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 7 June 2016 Resolved
Provide double hose clamps on machinery hoses where practicable.
Due 10 July 2016
Resolved 7 July 2016
Engineering › Steering Gear System › Solenoid Valve
Issued 7 June 2016 Resolved
Port steering hydraulic actuating solenoid valve: Valve does not function when manually actuating the port push button as designed. Trouble shoot and repair or renew. Additionally, amend the emergency steering instructions to include local control method.
Due 9 July 2016
Resolved 7 July 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2016 Resolved
Replace a missing florescent light cover located overhead in the STBD side gray water tank compartment.
Due 9 July 2016
Resolved 7 July 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 7 June 2016 Resolved
Replace a broken florescent light cover located overhead in the port side potable water tank compartment.
Due 9 July 2016
Resolved 7 July 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 June 2016 Resolved
Replace missing 120v receptacle cover located overhead in the port side potable water tank compartment.
Due 9 July 2016
Resolved 7 July 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 7 June 2016 Resolved
3rd deck port side exterior, behind bridge: The 120v receptacle outlet is not properly mounted and has an Apx 1" gap between the face of the receptacle and the housing/enclosure. .Correct issue.
Due 9 July 2016
Resolved 7 July 2016
Electrical › Electric Generation Source (emergency) › Ground Indicator
Issued 7 June 2016 Resolved
During testing of the emergency generator's engine jacket water cooling high temperature alarm system. It was discovered that there is also high water alarm shut down feature. This feature appeared to function, however, after the system automatically shut down the system would automatically restart Apx 5-10 seconds afterward. Research to assertain if this is expected action.
Due 9 July 2016
Resolved 24 January 2017
Resolution: Conducted satisfactory test of the emergency generator J/W high temp alarm.

Casualty record · 7

17 December 2010Routine · role: Involved in a Marine Casualty · activity 3913827
7 October 2012Routine · role: Involved in a Marine Casualty · activity 4516769
16 December 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4510790
18 December 2015Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 5784594
11 December 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 6334885
17 December 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6326319
27 November 2022Routine · role: Involved in a Marine Casualty · activity 7609320
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.