Records from 2014 to 2025. Most recent: inspection, 30 January 2025.
Documentation record
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST GULF MARINE LTD · GALVESTON, TX, UNITED STATES · built 2014
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
30 January 2025
Internal Structural Exam · COI Inspection · Drydock Exam · Cargo Tank Internal · MTSA Verification · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8070865
6 July 2022
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7490389
13 June 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7476022
13 June 2022
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7478587
25 May 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7459038
20 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7455164
10 June 2021
Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7201368
5 April 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7175889
30 October 2019
Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6843504
20 November 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6588211
17 October 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6290822
7 June 2017
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168448
30 May 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6160704
30 May 2017
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6160768
21 November 2016
MTSA Verification · Periodic Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6045328
14 September 2015
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5718381
9 June 2014
Cargo Tank Internal · Drydock Exam · COI Inspection · Initial Certification · MTSA Verification · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5004688
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 May 2022
Resolved
Subdivision of cargo spaces shall be at least equivalent to the requirements of ABS Standards. Upon conducting a round, the tankerman noticed a small pinhole leak in the cargo piping. Affect permanent repairs to include discharging cargo, cleaning tanks, and gas freeing. Repairs shall be made to the satisfaction of USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2022
Resolved 26 May 2022
Resolution: Cropped and renewed 8" x 7' long portion of vapor header piping. Pneumatic test sat.
Construction/Loadline › Hull › Hull Plating
Issued 30 May 2017
Resolved
Damage port bow approx 12ft wide, by 8ft high. Proceed to Tubal Cain in Lake Charles, LA for lightering then submit transit plan to MSU Lake Charles for transit to repair facility.
Action required: 705 - Other - as specified
Resolved 12 July 2017
Resolution: Repairs completed to the satisfaction of the Marine Inspector