Records from 1995 to 2025. Most recent: inspection, 15 July 2025.
Inspection history · 49
15 July 2025
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8185539
4 February 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8074540
1 April 2024
COI Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7887974
18 October 2022
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7579389
23 June 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7485321
14 October 2021
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7331065
30 August 2021
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7300342
17 June 2021
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7228506
8 June 2021
Damage Survey · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7219378
8 June 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7226926
20 April 2021
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7179287
21 January 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7128376
10 January 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7122223
10 December 2020
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7109176
13 October 2020
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7076096
14 May 2020
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6953038
18 July 2019
MTSA Verification · Administrative Inspection · Initial Certification · DAPI Audit · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6732419
30 January 2019
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6617851
6 December 2016
Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6075644
7 June 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4043391
17 May 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4014628
16 October 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3875431
6 March 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3692524
11 November 2009
Examination of Repairs · Administration · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3642702
9 November 2009
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3632105
27 September 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3603994
15 August 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3568577
11 June 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3233900
28 April 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3194633
17 April 2007
MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2908939
13 April 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2907314
16 November 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2822158
18 December 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2554808
1 September 2004
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2183595
27 July 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2146504
30 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1998656
12 October 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702813
30 April 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1615311
10 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2019
9 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 84018
9 November 2000
Uninspected Towing Vessel
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1057331
20 February 2000
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 275232
10 February 2000
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 64641
14 December 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 721386
9 December 1999
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 435628
17 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 190289
17 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 757323
5 March 1997
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 22702
9 February 1995
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 41092
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2025
Resolved
Nothing in this subpart limits the marine inspector from conducting any tests or inspections he or she deems necessary to be assured of the vessel's seaworthiness or fitness for its route and service. Attending MI shall conduct Steering test, Observe Main Engines operating properly, conduct drills. - 46 CFR 137.200(d) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Conducted satisfactory fire and man overboard drills.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2025
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Excessive oil in bilge. Accumulation of approximately 8 to 10 inches of dirty oil, fuel and water was observed in the bilge in the Engine Room. Remove oily water. - 46 CFR 142.220(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: verified all Machinery space bilges were free of oil and the oil/water observed during initial inspection was offloaded by regulated facility.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2025
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port Main engine fuel pump was observed to have steady leak of diesel. Stbd Main engine fuel pump was observed to have a weeping leak. Stbd Main engine Racor Fuel filter found with oil in metal catch basin. Repair to the satisfaction of attending Marine inspector. - 46 CFR 143.220(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: During operational testing of both main engines through examination of the racor filters and f/o pumps on both stbd and port main engines. all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 July 2025
Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, Liferafts must have float free arrangement… hydrostatic release unit. Life-raft Hydrostatic release expired one month ago. Replace.
- 46 CFR 141.310 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: verified new installation of hydrostatic release unit.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 15 July 2025
Resolved
Each towing vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station. 1. Rudder angle indicator centerline main bridge control station was inoperable. 2. Rudder angle indicator repeaters shows a range of 26* to 35* Re-calibrate rudder angle indicators with proper rudder range. - 46 CFR 143.225 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Conducted steering test locally and from the bridge. Rudder angle indicators were re-calibrated and verified a 35* to 35* shift. with no hesitation at the rams. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2025
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. 1. Port aft hydraulic steering ram was found with a broken seal. 2. Steering pump No.1 flex hose was found blistered. Replace. -
46 CFR 143.245(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Conducted steering test from the bridge. verified renewed Hydralic ram was installed, during tests there were no hesitation, and all seals were intact. all sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 July 2025
Resolved
Marine Sanitation Device must be free of defects that would allow toxic substances to escape to the interior of the vessel. The MSD was observed to have a failed gasket on the inlet side of the device where sewage effluent was leaking out of top of the box. Repair. - 33 CFR 159.95(a)(1) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Visually examined MSD, no leaks. all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2025
Resolved
A towing vessel that is certificated for Oceans route whose contract for construction prior to August 27, 2003 must have an approved 160-B semi-portable fire-extinguishing system to protect the engine room. Semi-portable fire-extinguisher was mounted to the second deck, but its hose was not long enough to provide firefighting capabilities to the engine-room at its current mounted location. Install hose of adequate length. - 46 CFR 142.315(a)(2) &(i) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 15 July 2025
Resolved
All persons employed or engaged onboard vessels to which STCW applies will be issued a medical certificate valid for 2 years. Medical Certificates for Master and OS found expired. - 46 CFR 10.301 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: Verified STCW medical certificate of the current vessel's captain, valid for service until 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. STBD main engine exhaust leak. Repair. - 46 CFR 143.205(a) - 17c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: Stbd Main engine exhaust leak was repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 15 July 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Multiple dead-end wires found though out the engine room, a wire nut spliced wire was found not in an enclosure. Breaker panel was found with missing cover. Remove electrical hazards. - 46 CFR 143.400(g) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: Cover was installed on the main electrical pannel. Dead end wire found on port side engine room was from an old system verified the removal of the wires for that obsolete system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. STBD Generator Exhaust Lagging missing. Replace. - 46 CFR 143.220(b) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: Verified lagging was properly installed and in place.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 July 2025
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Multiple catch basins and plastic buckets used to catch oil were observed through out the engine room. Remove. - 46 CFR 143.220(c) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2025
Resolution: All plastic catch basins(non manufacturer approved) around the engine room have been removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 15 July 2025
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Bridge to Bridge certificate was found expired. - 47 CFR 80.1005 - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 August 2025
Resolution: uploaded new bridge to bridge certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Each towing vessel operating on oceans, coastwise, or Great Lakes routes must have a means to take blood pressure readings, splint broken bones, and apply large bandages for serious wounds. First Aid Kit Expired equipment expired or missing, replace first aid kit.
- 46 CFR 140.435 - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2025
Resolution: verified additional equipment for Oceans/LBS route in First Aid Kit was onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 July 2025
Resolved
The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Heat Detector in E/R was tested and continued alarming once activated. O/O repaired with spares in stock. System was back to normal with no faults. - 46 CFR 142.330(a)(3) - 10c
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Corrected on the Spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025
Resolved
Each towing vessel must carry one appropriately-sized lifejacket for each person onboard. Missing One Lifejacket. - 46 CFR 141.340(a) - 10c
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Corrected on the Spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 25 April 2024
Resolved
Each towing vessel operating on oceans, coastwise, limited coastwise, or beyond 3 nautical miles from shore upon the Great Lakes must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon (EPIRB). Replace damaged EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2024
Resolved 1 May 2024
Resolution: Replaced damaged EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2024
Resolved
Each towing vessel 79 feet or more in length operating on oceans and coastwise routes that does not have an installed fixed fire-extinguishing system must have the following: At least two firefighter's outfits that meet NFPA 1971 and Two self-contained breathing apparatus of the pressure demand, open circuit type, approved by the National Institute for Occupational Safety and Health (NIOSH). Provide documentation showing the servicing of the Firefighting sets.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2024
Resolved 1 May 2024
Resolution: SCBAs were on board and serviced. Provided documentation showing the servicing of the Firefighting sets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 April 2024
Resolved
All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Provide evidence that the bilge suctions have a check/foot valve installed.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2024
Resolved 1 May 2024
Resolution: Verified bilge suctions all have a check/foot valves installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 April 2024
Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Install STBD generator flywheel machinery guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2024
Resolved 1 May 2024
Resolution: Installed STBD generator flywheel machinery guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Install lagging around port and STB MDE’s turbochargers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Installed lagging around port and STB MDE’s turbochargers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 April 2024
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Repair leaks and clean up oil on the Starboard generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Repaired leaks and cleaned up oil on the Starboard generator.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 April 2024
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Secure freezer and refrigerator located in the galley.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Secureed freezer and refrigerator located in the galley with an engineered metal strap.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Remove loose cables in the 02 deck of the engine room as well as place adequate outlet covers on all electrical outlets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 2 May 2024
Resolution: Removed loose cables in the 02 deck of the engine room as well as installed adequate outlet covers on all electrical outlets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Secure engine harness cabling located FWD STBD side of the STBD MDE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Secured engine harness cabling located FWD STBD side of the STBD MDE using screws provided on the back of the junction box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Provide marine grade battery charger for STBD generator battery bank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Installed marine grade battery charger for STBD generator battery bank.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 25 April 2024
Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump that is capable of Being energized remotely from a safe place outside the engine room and at the pump. Install remote fire pump controllers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Verified installation of remote fire pump controllers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Replace or repair ground detection button on the main switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Repaired ground detection button on the main switchboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2024
Resolved
All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew. Stencil MAWP on Port and STBD air receivers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Stenciled MAWP on Port and STBD air receivers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Mount and replace PORT generator oil pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 1 May 2024
Resolution: Installed PORT generator oil pressure gauge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 October 2022
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. VSL must undergo an Annual inspection before it can operate.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2022
Resolved 4 February 2025
Resolution: Vessel competed COI inspection.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 October 2021
Resolved
The owner, managing operator, or master of each towing vessel must maintain the required navigational safety equipment in a fully-functioning, operational condition. The compass light as found not operational, replace lightbulb and prove proper operations of compass light. 46CFR140.620.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 October 2021
Resolved
The VHF radios must be connected to a GPS receiver or have a VHF-DSC Marine Radio with integral GPS. The VHF radios have been found not to be displaying GPS coordinates. Prove proper operations of VHF-DSC radios by connecting them to a GPS receiver to display GPS coordinates; or install VHS-DSC radios with integral GPS. 47CFR80.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2021
Resolved
Each towing vessel must be equipped with at least two portable, battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. The two portable battery-powered lights has been found not operational. Provide at least two operational portable battery-powered lights. 46 CFR 143.410 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 October 2021
Resolved
Alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. The redundant alarm panel installed in the operating station was not found properly operating by resetting and shutting-off every time the high bilge water alarm was activated. Prover proper operation of redundant operating station alarm panel in the presence of an attending U.S. Coast guard marine Inspector, and provide a roving watch to monitor the main alarm panel located in the engine room, and enter the watch in the logbook.46CFR143.230 (b)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 October 2021
Resolved
A fire detection control panel or a remote indication panel must have visual alarm alarms to identify the zones or zones of origin of the fire. Crew was unfamiliar with the different alarm zones identified in the fire alarm detection panel upon testing. Provide a diagram or list that identifies the different fire zones and post it next to the fire detection panel.46 CFR 142.330 (3) (iii).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 October 2021
Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such openings. The means of securing the starboard side funnel exhaust ventilation cover was found to have missing the securing bolt and unable to be closed. Prove the proper operation of the ventilation cover in for the satisfaction of an attending USCG Marine Inspector. 46CFR 144.605.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 October 2021
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. The rotary machinery guard of the winch generator was found broken and laying on the deck, with the base of the securing screw also broken. Repair or replace broken rotary machinery guard and install on its location.46 CFR 144.820
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 October 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids, insofar as practicable. Remove and clean engine room bilges as it was found with a large considerable amount of oily bilge water.46 CFR 142.220.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids, insofar as practicable. Remove all deck covers in the engine room and remove all debris, trash, rags and parts that were found in the engine room bilges.46 CFR 142.220.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2021
Resolved
Storage areas are kept free from accumulation of combustible and flammable materials insofar as practicable. Remove all flammable materials such as cardboard and excess clutter of equipment that are not in use from the engine room and deck above engine room, adjacent to the mooring equipment. 46 CFR 142.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2021
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. The starboard side generator was found to have a battery without a leak proof tray. Install battery tray and secure battery.46 CFR143.400 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 14 October 2021
Resolved
Closure devices must be provided for hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. The slop-holding tank located in the engine room was found to have missing its closing device for at least 5 days. Re-install closing device and make sure it remains installed to prevent spill or water intrusion.46CFR144.320 (b).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 October 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Two lighting fixtures has been found without its cover. Properly install lighting fixture covers.46 CFR 143.400.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2021
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. All three generators, both port and starboard main diesel engines and towing gear winch at the stern of the vessel has been found leaking, creating a fire hazard. Properly maintain or replace gaskets and clean machinery, generators and towing winch. 46 CFR 143.220 (a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2021
Resolved
The strength of each component used for securing the towing vessel to the tow and for making up the tow is adequate for its intended service. Properly replace a 10 to 12 feet segment of towing cable that was found to to have frayed wires in the stern towing winch. 46 CFR 140.801.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2021
Resolved 29 October 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2021
Resolved
After any survey of the ship has been completed, no change shall be made in the structure or scantlings without the sanction of the Administration. The vessel was found with uncertified welders on board the vessel conducting hotwork by welding on the #2 starboard fuel tank vent without notifying the U.S. Coast Guard(Administration) nor the American Bureau of Shipping (Recognized Organization). Furthermore, tank vent pipe diameter was modified from 3.5" to 2.5" diameter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2021
Resolution: Conditions has been met by ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 June 2021
Resolved
No alteration or repair involving welding shall be made within or on the boundaries of fuel tanks without the inspection and approval of a marine chemist certificated by the National Fire Protection Association (NFPA). The vessel was found with welders on board conducting hotwork by welding on the #2 starboard fuel tank vent without the proper inspection and issuance of a Marine Chemist Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2021
Resolution: Repair conducted and space was cert by a marine chemist.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2021
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel propeller has to be inspected, and diving report must be provided, to assure extend of damage by their towing cable on their propellers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 April 2021
Resolved
Vessels described in Table 136.250 of this section that operate on the Great Lakes or outside the Boundary Lines, as set forth in 46 CFR part 7, are subject to load line requirements in subchapter E of this. Vessel is to return to Ceiba, PR and await a damage survey from marine inspectors prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 April 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 January 2021
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. In addition, the master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Aft port ballast tank hatch cover and Stbd access hatch to steering gear compartment were both missing one bolt.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 22 January 2021
Resolution: Bolts added to hatch covers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 January 2021
Resolved
A workspace must be of adequate construction to provide for the protection of the crew. Engine room stair rail loose and unstable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 22 January 2021
Resolution: Rail properly secured.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 21 January 2021
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. In addition, the master must ensure that all hatches, doors, and other openings designed to be watertight function properly. Each weathertight door in the main deck at the port and starboard sides have inadequate gaskets, frozen dogs, and do not properly close.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2021
Resolution: Gaskets installed properly. Previously frozen dog now working correctly. Door closes correctly.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 January 2021
Resolved
Each vessel must have a stability letter issued by the Coast Guard and comply with its conditions of operation. This includes maintaining the bilges pumped to a minimum the content at all times. The engine room has a high amount of oily water in the bilges and it was as deep as 2.5 feet in some areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2021
Resolution: Recieved "Declaration of Inspection prior to Bulk Cargo Transfer" between vsl and oily bilge remover. Witnessed low bilge level.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 January 2021
Resolved
All seals and gaskets must be properly maintained to
prevent leaks of flammable or combustible liquid into
the machinery space. The fuel oil manifold main valve
was found leaking and had a diesel soaked rag tied
around it.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2021
Resolution: Fuel manifold valve replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2020
Resolved
The owner and managing operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulation at all times. USCG MI observed that the port side engine and generator were completely torn down and inoperable at the time of a scheduled Annual Inspection. Essential equipment was unavailable for inspection and testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2020
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 October 2020
Resolved
The system is installed,tested, and maintained in accordance with the manufacturer's design manual. MI observed a flashing amber trouble light on the fire detection panel that could not be cleared by the vessel crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2020
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 October 2020
Resolved
Each towing vessel must be maintained and operated so as
to minimize fire hazards and to ensure the following:
All bilges and void spaces are kept free from
accumulation of combustible and flammable materials
insofar practicable. Coast Guard Marine Inspectors
observed an excessive accumulation of combustible
materials (oil) in the machinery space bilge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2020
Resolved
Each remote valve control must be marked in clearly
legible letters, at least 25mm (1 inch) high, indicating
the purpose of the valve and the way to operate it. MI
observed that the sticker, labeling the remote valve
control for the fuel shut off valve was ripped and
illegible.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2020
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 15 October 2020
Resolved
A single Side band radiotelephone capable of operating
on all distress and safety frequencies in the medium and
high frequencies bands listed. MI observed the SSB radio
had been removed due to age and lack of capability and
not yet replaced.
Action required: 702 - Prior to embarking on international voyage
Resolved 10 December 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 October 2020
Resolved
All vessel equipment must be used in accordance with the
manufacture's recommended recommend practice and in a
manner that minimizes risk of injury or death. This
includes machinery, deck machinery, towing gear,ladders,
embarkation devices, cranes, portable tools, and safety
equipment. Marine Inspector observed an unsecured and
uncapped propane cylinder on deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 October 2020
Resolved
Each towing vessel must be equipped with an industrial
type first aid kit cabinet or kit, appropriate to the
size of the crew and operating conditions. Marine
Inspector observed many of the first aid kit items were
expired
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 October 2020
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Coast Guard Marine Inspector observed the following
electrical hazards through-out the vessel:
Dead-end exposed electrical wiring in way of batteries
located in aft operating station.
Unmounted electrical outlet above galley oven.
Electrical box in forward Port side main machinery space
did not have the required cover.
Light bulbs missing protective covers in head and
forward compartment.
Galley stove top was missing one element, exposing
interior electrical connecter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 July 2019
Resolved
Guards missing from machinery space lights in engineroom.
46 CFR 143.410
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 2 August 2019
Resolution: Installed guard, Photos provided
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 July 2019
Resolved
Guards missing on sight glasses in engineroom, 46 CFR 56.50-80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 2 August 2019
Resolution: Installed Guards, Photos provided
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2019
Resolved
Fire pump & Raw water pump are missing 2 and 4 bolts respectively. 46 CFR 142.325
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 2 August 2019
Resolution: Bolts installed, phothos provided
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 July 2019
Resolved
Demonstrate working pressure and flow rate of fixed fire pump either by means of a pitot tube or by installing a gauge. 46 CFR 142.325
Action required: 10 - Deficiency Rectified
Due 18 August 2019
Resolved 21 August 2019
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 18 July 2019
Resolved
Magnetic compass light is not functioning. 46 CFR 140.725
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 2 August 2019
Resolution: Compass light operating, photos provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 July 2019
Resolved
Watertight gasket in wheelhouse is not cut to fit and made with a proper seal. 46 CFR 137.220
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2019
Resolved 2 August 2019
Resolution: New gasket installed, photos provided
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 April 2008
Resolved
Vessel fouled starboard propeller with main tow wire. Currently located at the ADM terminal in Southport, NC effecting repairs.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2008
Resolution: Line removed from shaft, rudder and wheel by Atlantic Coast Industrial divers
Navigation
Issued 9 December 1999
Resolved
A VIOLATION OF 33 C.F.R. 86.23 IN THAT THE UTV DRIVER HAD IMPROPER BELL SIZE AND BELL WAS MISSING IT'S STRIKER.
Condition: Unknown
Due 26 February 2000
Resolved 26 February 2000
Lifesaving
Issued 9 December 1999
Resolved
A VIOLATION OF 46 C.F.R. 28.135 IN THAT THE UTV DRIVER FAILED TO MARK PFD'SWITH THE REQUIRED NAME OF THE VESSEL ON THE BACK OF THE PFD.
Condition: Unknown
Due 26 February 2000
Resolved 26 February 2000
Documentation › Markings/Placards › Certificate of Number (state)
Issued 9 December 1999
Resolved
A VIOLATION IN THAT THE UTV DRIVER FAILED TO HAVE THE OFFICIAL NUMBER PERMANENTLY AFFIXED TO AN INTERIOR STRUCTURE.
Condition: Unknown
Due 10 January 2000
Resolved 1 September 2004
Resolution: Recieved master''s statement this date.
Documentation › Logs/Records › Logbook (official)
Issued 9 December 1999
Resolved
A VIOLATION OF 46 U.S.C. 8104(D) IN THAT THE UTV DRIVER DOES NOT HAVE SUFFICIENT PERSONNEL TO STAND THE REQUIRED THREE WATCHES THAT IS REQUIRED FOR VESSELS OVER 100GT.
Condition: Unknown
Due 10 February 2000
Resolved 1 September 2004
Resolution: Recieved master''s statement this date.
Lifesaving
Issued 9 December 1999
Resolved
A VIOLATION OF 46 C.F.R. 28.135 IN THAT THE UTV DRIVER FAILED TO HAVE THE NAME OF THE UTV MARKED ON THE FRONT OF THE LIFERING.
Condition: Unknown
Due 26 February 2000
Resolved 26 February 2000
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 December 1999
Resolved
A VIOLATION OF 33 C.F.R. 159.59 IN THAT THE UTV DRIVER FAILED TO HAVE PLACARDS ATTACHED TO MSD WHICH PROVIDE SAFETY PRECAUTIONS, OPERATING INSTRUCTIONS AND WARNINGS PERTINENT TO THE MSD.
Condition: Unknown
Due 10 January 2000
Resolved 1 September 2004
Resolution: Recieved master''s statement this date.