Records from 2016 to 2026. Most recent: inspection, 28 July 2026.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 3.5 ft
Registered tonnagegross 12 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT PONTOONS INC · TAVARES, FL, UNITED STATES · built 2014
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTri Hull
Hailing portCHINCOTEAGUE, VA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 29 July 2014
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
12 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
28 July 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8445707
21 May 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8138996
3 June 2024
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7922545
15 May 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7912676
17 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7786387
5 April 2023
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7663197
3 May 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7442444
12 August 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7281790
28 July 2020
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7018276
16 July 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7001975
8 June 2020
Administrative Inspection · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968963
8 October 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6828363
18 September 2019
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6818742
26 May 2019
Type not recorded
No type recorded · Station Chincoteague · USCG East District (CGD-E) · Activity 6695242
24 September 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6545788
24 May 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6399447
14 August 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6240678
25 July 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6170256
23 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5917414
9 June 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5894925
24 May 2016
Deficiency Check · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5899872
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 July 2026
Resolved
All machinery and equipment must be installed and
maintained in such a manner as to afford adequate
protection from causing fire, explosion, machinery
failure, and personnel injury. Fuel supply hose between
stbd tank and fuel filter is degraded.
46 CFR 182.100
Action required: 10 - Deficiency Rectified
Due 28 July 2026
Resolved 28 July 2026
Resolution: Received photos of renewed fuel hoses.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2026
Resolved
Portable extinguishers must be inspected and maintained
in accordance with NFPA 10. Vessel did not have record
of monthly portable fire extinguisher inspection.
46 CFR 176.810(b)(1)
Action required: 10 - Deficiency Rectified
Due 28 July 2026
Resolved 28 July 2026
Resolution: Corrected during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 July 2026
Resolved
All vessels must have navigation lights that are in
compliance with the applicable sections of the
International and Inland Navigation Rules. Vessel's
stern light is inoperable.
46 CFR 183.420
Action required: 10 - Deficiency Rectified
Due 28 July 2026
Resolved 28 July 2026
Resolution: Received photos of repaired stern light.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 August 2021
Resolved
A vessel not required to have power driven fire pump must have at least three 2.5 gallon buckets. Only two serviceable buckets on board; provide third bucket to meet standard. To the satisfaction of the OCMI.
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Owner produced a third fire fighting bucket
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel.Vessel was missing 04 adult PFD's.
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Owner of the vessel was able to produce 04 more adult PFD's.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 July 2020
Resolved
46 CFR 67.7
Any vessel at least 5 NT must have a valid Certificate of Documentation. The COD was expired. Provide valid COD to USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2020
Resolution: Renewed COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2020
Resolved
46 CFR 183.200(b)
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and other persons onboard. Dead end wires were found in the stbd fwd portion of the passenger cabin. Remove or repair dead end wires to satisfaction of USCG MI.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2020
Resolution: Crew removed wires.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 June 2020
Resolved
During the exam all accessible parts of the vessel underwater body and all through hull fittings. Passenger entry door not attached to the hinge.
Action required: 705 - Other - as specified
Resolved 30 June 2020
Resolution: The passenger door was properly attached to its hinge.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 July 2017
Resolved
Ring life bouy lifeline not proper size. Replace to satisfaction of marine inspector.
Due 14 August 2017
Resolved 14 August 2017
Resolution: Vessel owner provided image of new life ring and throw line.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 June 2016
Resolved
Found vessel's Certificate of Documentation to be expired. COD was renewed online. Owner will need to provide proof of renewed COD.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016