Records from 2007 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 20
21 May 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8378107
21 May 2025
Annual Inspection · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8139003
29 May 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7922549
17 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7786387
4 April 2023
COI Inspection · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7662423
12 August 2021
COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7281434
16 July 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7008085
8 June 2020
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968948
9 October 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6834992
18 September 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6813775
24 May 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6421786
26 April 2018
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6399459
25 July 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6173172
9 June 2016
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5916214
23 May 2016
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5884104
27 January 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5801600
1 October 2010
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3859621
2 October 2008
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3320081
15 November 2007
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3091775
2 July 2007
Simplified Stability Test · Plan Review "T" Boat · Construction Oversight
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2981113
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 21 May 2026
No resolution recorded
Vessel was missing two 2.5 gallon fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2026
No resolution recorded
Vessel had one corroded fire extinguisher bracket that was broken and missing hardware.
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 May 2024
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel name on ring life buoy had missing letters. 46 CFR 185.604(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 11 June 2024
Resolution: Received image of corrections to labeling requirements, uploaded into documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel’s engine had loose seal on cowling surrounding throttle control and fuel line. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2024
Resolved 7 June 2024
Resolution: received image of cowling repairs, uploaded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Life jacket instructions did not match the life jackets onboard. 46 CFR 185.516(a)
Action required: 10 - Deficiency Rectified
Due 3 June 2024
Resolved 3 June 2024
Resolution: Proper placard placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2021
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation. Water light is onboard, but does not have a battery that meets manufacturer specifications; replace waterlight batter that meets manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2021
Resolved 21 August 2021
Resolution: Owner received/installed the correct marker light battery IAW manufactures specifications.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 August 2021
Resolved
Six life jackets were not labeled with the vessels name.
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Owner added the name of the vessel to each life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 August 2021
Resolved
The distress signal bag was not labeled as "distress signals."
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Owner labeled the distress signal bag as "distress signals."
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2021
Resolved
The three firefighting buckets were not stenciled with "FIRE BUCKET."
Action required: 10 - Deficiency Rectified
Due 12 August 2021
Resolved 12 August 2021
Resolution: Owner stenciled the fire buckets with the words "FIRE BUCKET."
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 July 2020
Resolved
33 CFR 83.23
Power driven vessels shall exhibit a sternlight. Vessel's sternlight would not power on. Vessel cannot operate after beyond dusk hours until the sternlight is repaired. Repair stern light to satisfaction of attending USCG MI.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2019
Resolved
Found 30 adult and 02 children life jackets unserviceable due to extensive wear and UV exposure. All unserviceable jackets were destroyed on spot, provide proof of adequate number of serviceable life jackets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2019
Resolution: Provided proof of 30 adult and 02 child sized, serviceable PFDs.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 September 2019
Resolved
Found operating station portable fire extinguisher unserviceable and missing bracket. Provide proof of serviceable fire extingisher and install manufacturer appropriate mounting bracket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2019
Resolution: Installed manufacturer reccomended portable fire extinguisher bracket.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 September 2019
Resolved
Found stability letter not posted, missing from vessel. Provide proof of valid stability letter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2019
Resolution: Provided proof of posted stability letter.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 July 2017
Resolved
Ring life buoy lifeline is the incorrect size. Replace to the satisfaction of the attending CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 14 August 2017
Resolution: Vessel owner replaced the ring life buoy with correct life line and waterlight attached.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2016
Resolved
Missing 09 adult life jackets, restricted vessel’s passenger count to 25 adult passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Vessel O/O provided 09 missing adult lifejackets; all sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2016
Resolved
Water light and retaining lanyard was broken, restricted vessel to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Inspected new waterlight and lanyard; all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2016
Resolved
Incomplete first aid kit, O/O is to replace missing items to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Inspected replacement items for first aid kit; all sat.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 November 2007
Resolved
Post emergency instruction and stability letter.
Due 21 November 2007
Resolved 20 November 2007
Electrical › Electrical Distribution System (service) › Switch
Issued 15 November 2007
Resolved
Mark switch at helm
Due 21 November 2007
Resolved 20 November 2007