Records from 2001 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 54
25 February 2026
COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8316483
4 July 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8178259
9 June 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8155888
14 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8034431
6 May 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7907153
10 May 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7685407
1 November 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7571153
5 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7525631
23 March 2022
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417467
11 March 2021
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7154423
20 November 2020
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7101911
9 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6999311
9 September 2019
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6807162
14 November 2018
Hull Examination · Administrative Inspection · In-Service Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6580016
3 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6404454
18 April 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127001
9 January 2017
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6067857
8 June 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5901455
21 March 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5837188
2 June 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4876775
15 May 2012
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4320237
21 December 2011
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4228704
1 December 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4199528
6 January 2011
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3921929
13 July 2009
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3535603
13 January 2009
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3393360
19 August 2008
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3303912
14 July 2008
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3267948
20 June 2007
Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975903
6 March 2007
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2882802
5 February 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2867338
30 August 2006
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2763880
12 June 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2677438
12 June 2006
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2677886
18 April 2006
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2627057
17 May 2005
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2360212
5 January 2005
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2269072
27 April 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2053533
19 April 2004
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2047271
10 November 2003
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1945114
28 April 2003
Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1781832
7 April 2003
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1769348
13 February 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1747678
12 December 2002
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1717883
15 April 2002
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604950
11 April 2002
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1603666
9 April 2002
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1602583
10 December 2001
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077241
24 September 2001
Damage Survey
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1465697
20 September 2001
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 183943
23 May 2001
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1448295
6 May 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 111178
26 April 2001
Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1469648
1 February 2001
Plan Review "T" Boat
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1432454
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 August 2022
Resolved
STBD prop shaft has large crack
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 August 2022
Resolved 19 August 2022
Resolution: Operator/Shipyard submitted satisfactory pictures.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts or large enough scale to make safe navigation possible. Marine Inspector witnessed last chart update being from 2020. Vessel must provide proof of updated charts within 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 14 April 2022
Resolution: vessel recieved new charts
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 March 2022
Resolved
A hatch exposed to the weather must be watertight. Marine Inspector observed port side machinery space porthole not to be watertight. Vessel must provide proof of temporary repair to make porthole watertight within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 April 2022
Resolved 14 April 2022
Resolution: Porthole restored to water tight
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 March 2022
Resolved
A hatch exposed to the weather must be watertight. Marine Inspector observed port side machinery space porthole not to be watertight. Vessel must make porthole permanently watertight prior to next credit dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 1 November 2022
Resolution: Complete prior to next drydock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 March 2021
Resolved
CO2 shutdowns inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 March 2021
Resolved
The vessel's Captain is in a DOT program but not in the vessel's consortium. Must be in compliance with company consortium. .
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2021
Resolved
Protect from electrical hazard exposed battery wire on stbd engine battery bank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2021
Resolved
Protect from electrical hazard unsecured battery covers on P&S engine and gen set battery banks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 March 2021
Resolved
Protect from electrical hazard chaffed and lose wires aft of port engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2021
Resolved
Placards for lifejackets instruction must be posted. Vessel has two types of lifejackets but only 1 set of directions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 March 2021
Resolved
Vessel's base plate for anchor motor in void #1 is wasted, must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 March 2021
Resolved
Number of lifejackets must be posted on storage location, missing and inproper instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 15 March 2021
Resolved
Vessel must have an acceptable method of securing sewage overboard discharge valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2021
Resolved
Vessel did not have a drug & alcohol company policy, must provide company policy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2021
Resolved
Vessel must have alcohol testing devices onboard, devices on board are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2021
Resolved
Vessel must show proof of DAPI MIS report was submitted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 15 March 2021
Resolved
Vessel needs at least 50% of total crew CPR/Fist aid trained.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 March 2021
Resolved
Must provide an up to date and current chart for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 March 2021
Resolved
Vessel's engine room ventilation contains combustibles, plastic pipe & plastic opening, which are not allowed, must make all machinery ventilation ducting meet the regulation by being same construction as the hull and noncombustible materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 March 2021
Resolved
Prove that the mattress in accommodation spaces meet the regulation. (FF 4-72.16 16CFR1632 or IMO resolution A.688(17)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 March 2021
Resolved
Emergency lighting is required along escape routes from crew and passenger accommodation. (FWD bathrooms & Engine room currently don't exist in these area's)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 March 2021
Resolved
Vessel must have a public address system that meets the regulation. Vessel does not have a system currently.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 March 2021
Resolved
Vessel's Rescue Boat/MOB current arrangement does not meet the regulation and/or the OCMI alternate arrangements. Vessel's master has no communication or line of sight from the operating station. Additionally Crew standing on a small platform on stern creates a hazardous situation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 15 March 2021
Resolved
Vessel's port lights must have a hinged dead cover. The vessel currently has the metal port light covers missing in various location and this must be corrected to original design as approved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 28 May 2021
Resolution: Attending marine inspector witnessed satisfactory resolution of deficiency.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 September 2019
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Vessel shall conduct abandon ship and man overboard drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 12 September 2019
Resolution: Received copies of vessels log showing drills were completed by crew.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 9 September 2019
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Vessel shall conduct fire drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2019
Resolved 12 September 2019
Resolution: Received copies of vessels log showing drills were completed by crew.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 September 2019
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Bilge alarm/float switch connection is not in an enclosure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 25 September 2019
Resolution: Received photos clearing deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 September 2019
Resolved
Vessel must carry a first aid kit approved under 46cfr160.041 or a kit with equivalent contents. Provide approved first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 12 September 2019
Resolution: Received photos and documentation showing vessel has a CG approved first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 September 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: US Coast Pilot [name withheld] List and Navigation Rules of the Road (COLREGS). Provide updated copies of US Coast Pilot [name withheld] List and Navigation Rules of the Road.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 12 September 2019
Resolution: Received photos showing updated navigationl pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2019
Resolved
A vessel must carry one floating water light. Replace expired floating water light battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 12 September 2019
Resolution: Received photos showing new battery placed into service in floating water light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2019
Resolved
An employer must ensure that they and their crew members meet the requirements of this part. Provide annual consortium report as well as updated list of tested employees with results.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2019
Resolved 12 September 2019
Resolution: Electronic documentation was submitted, highlighting the company/employee's enollment in a DAPI Consortium.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2018
Resolved
Certificate is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 10 May 2018
Resolution: Vessel provided a FCC Safety Radio Certificate
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 3 May 2018
Resolved
Fire extinguishing equipment installed in excess of what is required must be maintained. The remote manual engine shut downs for the CO2 system do not operate as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2018
Resolved 18 May 2018
Resolution: Technician verified proper operation of shut downs.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 18 April 2017
Resolved
Vessel needs placards for all types of Type I Lifejackets available.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 24 April 2017
Resolution: Vessel had placard installed for all Type I lifejackets.
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2017
Resolved
See repair proposal attached to activity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 February 2017
Resolved 2 February 2017
Resolution: Repaired wasted area of hull.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 15 May 2012
Resolved
MPE gages in pilothouse inoperable
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 11 July 2012
Resolution: Recieved IMMT Maintenance Service Report attesting to the Electrical Service Rendered which replaced main engine instrument panel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 May 2012
Resolved
Pilothouse Bi extinguisher past due for service
Action required: 705 - Other - as specified
Due 22 May 2012
Resolved 30 May 2012
Resolution: Recieved Maintenance report.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 January 2011
Resolved
Rail forward of the pilothouse is 34 in. and not of appropriate height to provide for passenger safety. Do not allow passengers on upper deck forward of pilot house until the deficiency is resolved to the satisfaction of the CG inspector. Vessel is permitted to post a sign and enforce passenger restrictions with crew.
Action required: 705 - Other - as specified
Resolved 20 May 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 January 2011
Resolved
Railing aft on upper deck is not constructed to withstand 200 lbs. Railing is also not of sturdy configuration to provide for passenger safety. Provide deck railing for the vessel that meets the requirements found in 46 CFR 177.900 to the satisfaction of the CG inspector prior to carrying passengers on the upper deck.
Action required: 705 - Other - as specified
Resolved 20 May 2011
Engineering › Fuel Oil Service System › Filter
Issued 6 January 2011
Resolved
Provide flame shield for generators (port and starboard side) as discussed.
Action required: 705 - Other - as specified
Resolved 14 February 2011
Resolution: Vessel provided / installed flame sheilds for port / stbd genset fuel systems.
Construction/Loadline › Hull › Longitudinal Frame
Issued 13 January 2009
Resolved
V/W crack along the the frame for the foundation on the port side MDE as marked and discussed with the vessel representative.
Due 19 June 2009
Resolved 13 July 2009
Resolution: Crack was welded.
Stability › Watertight Integrity › Deadlight Cover
Issued 13 January 2009
Resolved
Repair broken port light cover IWO engiune room, starboard side forward as discussed with the vessel representative.
Due 19 June 2009
Resolved 13 July 2009
Resolution: Port light cover was secured/repaired.
Documentation › Logs/Records › Drug Test Records
Issued 14 July 2008
Resolved
Provide valid Drug and Alcohol Testing Program with enrollment and list of crewmember names. **PTCP**
Action required: 705 - Other - as specified
Resolved 15 July 2008
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 14 July 2008
Resolved
Properly mark and test emergency fuel shut-off valve station as discussed with Marine Inspector. **PTCP**
Action required: 705 - Other - as specified
Resolved 15 July 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 July 2008
Resolved
Provide and post Certificate of Documentation. **PTCP**
Action required: 705 - Other - as specified
Resolved 15 July 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 14 July 2008
Resolved
Provide CO2 activation instructions at CO2 pull station. **PTCP**
Action required: 705 - Other - as specified
Resolved 15 July 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 July 2008
Resolved
Properly secure battery boxes in engine room.
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 August 2008
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 14 July 2008
Resolved
Replace port-side muffler generator.
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 August 2008
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 14 July 2008
Resolved
Securely mount stbd-side muffler generator.
Action required: 705 - Other - as specified
Due 14 August 2008
Resolved 19 August 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 June 2007
Resolved
Provide life jacket donning placard for aft deck area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Provided LJ Donning Placard as Proper.
Documentation › Certificates/Documents › FCC SSL
Issued 20 June 2007
Resolved
Obtain FCC safety radio certificate. Vessel operation restricted to no more than 1000 feet from shore until this requirement is met.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Provided FCC Safety of Radio Certificate as Proper.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2007
Resolved
Install wire splice for AC unit in aft cabin closet in an enclosure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Properly Installed wire Splice for AC unit in aft cabin space as Proper.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 June 2007
Resolved
Repair/remove light fixture in AC closet (exposed wires).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Properly Repaired AC loset light fixture as Proper.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2007
Resolved
Install wire brackets for AC unit wiring in aft cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Properly Installed Wire Brackets for AC Unit Wiring in aft cabin.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 June 2007
Resolved
Provide proper bracket for fire extinguisher in closet at bottom of cabin stairwell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Removed Extra Fire Extinguisher from Vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 June 2007
Resolved
Remove outlet strips, main cabin aft (stereo cabinet at stairwell).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Removed Electrical Outlet Strips from Vessel.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 June 2007
Resolved
Secure junction boxes under seat, port side aft deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Properly Secured Junction Boxes under aft deck seating.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 June 2007
Resolved
Re-attach or enclose light fixture wiring (above galley reefer).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Properly Re-attached lighting fixture wiring within a Junction Box.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 June 2007
Resolved
Permanently repair wet exhaust piping leak on port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Made Proper Repairs to Wet Exhaust System Leak.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 June 2007
Resolved
Make repair to aft bilge high level alarm visual indicator light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 24 July 2007
Resolution: Made proper repairs to aft bilge high level alarm visual indicator light on bridge.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 5 February 2007
Resolved
Double clamp all flex hose/piping connections on wet exhaust for starboard MDE.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Double clamps installed.
Stability › Watertight Integrity › General
Issued 5 February 2007
Resolved
Make aft engine room bulkhead penetration watertight, starboard side, near bilge.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Bulkhead penetration sealed.
Construction/Loadline › Hull › Side Shell
Issued 5 February 2007
Resolved
Make permanent and proper repair to starboard side stabilizer.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: New stabilizer installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 February 2007
Resolved
Make permanent repair to hole in starboard generator wet exhaust pipe.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Pipe hole welded.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 February 2007
Resolved
Secure leak on port side generator wet exhaust pipe/flex hose connection.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: New flex hose installed and double clamped.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 February 2007
Resolved
Provide means to secure batteries for port and starboard generators.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Battery containers secured with cargo tie-downs.
Construction/Loadline › Penetrations › Valve Flange
Issued 5 February 2007
Resolved
Secure strainer for air conditioner raw water intake.
Action required: 705 - Other - as specified
Resolved 28 February 2007
Resolution: Strainer secured with new bracket installation.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2006
Resolved
Repair/Replace light fixture in forward space #1.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 July 2006
Electrical › Lighting (service) › Outlet Box
Issued 18 April 2006
Resolved
Properly terminate remove dead end wires in guest state room closet.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Deck/Cargo › Cargo Stowage › General
Issued 18 April 2006
Resolved
Repair hinges on doors hatches to forward seat.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2006
Resolved
Remove/properly terminate dead end wires under forward seat as discussed.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2006
Resolved
Remove /properly terminate dead end wires off the port MDE battery bank.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2006
Resolved
Replace hoses on stabilizer (stbd side), currently cracked.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Deck/Cargo › Cargo Stowage › General
Issued 18 April 2006
Resolved
Investigate source of anti freeze leak in e/r.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 April 2006
Resolved
Remove / renew dead end wire off stbd generator.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Engineering › Diesel Engine (propulsion-direct drive) › Spark Arrestor (exhaust)
Issued 18 April 2006
Resolved
Remove / Replace bracket over pipe in e/r deck as discussed.
Condition: Improper/Lack of Maintenance
Due 17 May 2006
Resolved 12 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 April 2006
Resolved
Clean bilges in e/r and fwd space as discussed.
Condition: Unknown
Due 17 May 2006
Resolved 12 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 April 2006
Resolved
Repair exhaust lagging as discussed.
Condition: Unknown
Due 17 May 2006
Resolved 18 April 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2005
Resolved
Replace line and battery for waterlight.
Due 24 May 2005
Resolved 1 June 2005
Resolution: Viewed new line and battery for waterlight.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 May 2005
Resolved
Provide servicing certificate for all portable and fixed fire fighting extinguishing systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2005
Resolution: Rcv''d copies of the Inspection Report and Certificates for the testing of the Calypso fire fighting equipment. Cleared NY05 for Portable and Fixed Fire Fighting Extinguishing Systems on this date.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2005
Resolved
Replace lines on liferings.
Due 24 May 2005
Resolved 1 June 2005
Resolution: Viewed new lines on lifering.
Engineering › Bilge Water Management System › Strainer
Issued 17 May 2005
Resolved
Place strainers over MDE PTO bilge suction hoses.
Due 24 May 2005
Resolved 1 June 2005
Resolution: Strainers have been placed over the PTO suction hoses.
Engineering › Bilge Water Management System › Not Operational
Issued 17 May 2005
Resolved
Replace or repair LO-HI level bilge alarm in E/R. Crew must make 15 min rounds of the e/r bilges, and log same, while u/w with passengers until this item is cleared by a CG MI.
Due 24 May 2005
Resolved 1 June 2005
Resolution: Bilge alarms was repaired, viewed and heard alarm.
Engineering › Bilge Water Management System › Piping
Issued 17 May 2005
Resolved
Secure E/R High level (bilge) alarm so that it can operate without interference from wires and frames.
Due 24 May 2005
Resolved 1 June 2005
Resolution: Wires and frames have been secured.
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 April 2004
Resolved
Prove proper operation of magnetic compass light.
Due 26 April 2004
Resolved 19 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 April 2004
Resolved
Provide CG approved (160.041) First Aid Kit or equivalent.
Due 26 April 2004
Resolved 6 May 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 19 April 2004
Resolved
Prove proper operation of emergency engine shutdowns outside E/R door.
Due 10 May 2004
Resolved 6 May 2004
Engineering › Fuel Oil Service System
Issued 19 April 2004
Resolved
Provide 30x30 mesh screen on fuel vents. LEGACY COMPONENT DESC: Ventilation
Due 26 April 2004
Resolved 6 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 28 April 2003
Resolved
Provide proof of first aid/CPR training for at least 50% of the crew as required by NVIC 1-91.. LEGACY COMPONENT DESC: First Aid/CPR training
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Resolution: Training recommended
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 April 2003
Resolved
Provide "proof of servicing" for fixed fire fighting system as required by 46 CFR 176.810(b)(2). Correct prior to departure. LEGACY COMPONENT DESC: Certificate of service
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 1 May 2003
Resolution: Servicing completed.
Operations/Management › Drug and Alcohol Testing
Issued 28 April 2003
Resolved
Provide drug and alcohol program for vessel/crew as required by 46 CFR 16. Correct prior to departure. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2003
Resolved 1 May 2003
Resolution: Documentation provided.
Operations/Management › Drills/Instruction
Issued 28 April 2003
Resolved
Provide/post emergency instruction list as required by 46 CFR 185.510. LEGACY COMPONENT DESC: Emergency Instruction list posted
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Engineering › Fuel Oil Service System
Issued 28 April 2003
Resolved
Repair leak in port inboard MDE Racor filter as required by 46 CFR 182.455(b)(6). Correct prior to departure. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2003
Resolved 1 May 2003
Navigation › Piloting/Steering
Issued 28 April 2003
Resolved
Provide current copy of US Coast Pilot and Light list applicable to route and service intended as required by 46 CFR 184.420(a)(2) & (3). LEGACY COMPONENT DESC: Coast Guard Light List/Coast Pilot
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 28 April 2003
Resolved
Provide enough life jackets to accomodate personnel authorized on COI as required by 46 CFR 180.71. Vessel restricted from carrying more than 40 persons and 6 children until additional PFD's have been properly marked and placed on board. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 28 May 2003
Electrical › Electrical Distribution System (emergency)
Issued 28 April 2003
Resolved
Label blank breaker in engine room as required by 46 CFR 183.220(d). LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Electrical › Electric Supply System (service)
Issued 28 April 2003
Resolved
Remove extension cord from forepeak compartment as required by 46 CFR 183.350(r). LEGACY COMPONENT DESC: Extension cord
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Engineering › Bilge Water Management System
Issued 28 April 2003
Resolved
Re-position bilge alarm floatswitch to operate as designed. 46 CFR 182.530(a). LEGACY COMPONENT DESC: Bilge alarm floatswitch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Cover electrical outlet cover in mate's cabin as required by 46 CFR 183.200(b). LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Secure outlet cover to emergency light and label plug accordingly in mate's cabin as required by 46 CFR 183.200(c). LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Lifesaving › Lifejacket/PFD (Type IV)
Issued 28 April 2003
Resolved
Repair / Replace lifering buoy to meet requirements of 46 CFR 180.70. LEGACY COMPONENT DESC: Retroreflective Material / Line
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2003
Resolved 1 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 April 2003
Resolved
Provide permanent railing of at least 30" high located on upper aft deck as required by 46 CFR 177.35-1 (Old-T). No passengers permitted on upper deck until requirement is fulfilled. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2003
Resolved 28 May 2003
Resolution: Rail installed in area of concern to raise the rail height to acceptable level of safety.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 April 2003
Resolved
Provide lagging on P/S MDE exhaust piping aft of turbo to muffler as required by 46 CFR 182.430(a). LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2003
Resolved 28 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 April 2003
Resolved
Install guards on P/S MDE's at alternator as required by 46 CFR 177.35-15. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2003
Resolved 28 May 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 28 April 2003
Resolved
Remove containers of alcohol exceeding a total capacity of 2.5 gallons or > from storage space below deck as required by 46 CFR 181.400(b)(2) or install a fixed gas F/F system. LEGACY COMPONENT DESC: No system for space
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2003
Resolved 1 May 2003
Resolution: Alcohol removed from cabinet below deck
Stability › Watertight Integrity
Issued 7 April 2003
Resolved
Install dead covers on all port lights below main deck. LEGACY COMPONENT DESC: Dead Covers
Condition: Unknown
Due 15 April 2004
Resolved 19 April 2004
Resolution: Vsl maintains a protected route and no longer needs dead covers.
Stability › Weathertight Integrity
Issued 7 April 2003
Resolved
Install/repair hatch locking device on forward cabin main deck hatch. LEGACY COMPONENT DESC: Hatch securing device
Condition: Improper/Lack of Maintenance
Due 11 April 2003
Resolved 16 April 2003
Stability › Watertight Integrity
Issued 7 April 2003
Resolved
Remove valve on aft side of collision bulkhead and install a cap or plug on the penetration. LEGACY COMPONENT DESC: Watertight bulkhead
Condition: Improper Installation
Due 11 April 2003
Resolved 16 April 2003
Construction/Loadline › Penetrations
Issued 7 April 2003
Resolved
Remove all plastic spool pieces and install metalic spool pieces with positive shut off valves at the penetration. LEGACY COMPONENT DESC: Spool piece
Condition: Improper Installation
Due 11 April 2003
Resolved 16 April 2003
Engineering › Sea-water System (primary cooling)
Issued 7 April 2003
Resolved
Properly repair or replace port and starboard main engines sea suction valves. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 11 April 2003
Resolved 16 April 2003
Electrical › Electric Generation Source (service)
Issued 12 December 2002
Resolved
Provide a data plate for both generators. LEGACY COMPONENT DESC: Generator
Condition: Unknown
Due 12 February 2003
Resolved 13 February 2003
Electrical › Lighting (emergency)
Issued 12 December 2002
Resolved
Install emergency lighting for escape routes in both forward and aft compartments below the main deck. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Due 12 February 2003
Resolved 13 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 12 December 2002
Resolved
Tighten all alternators and starters wiring connections on all engines. LEGACY COMPONENT DESC: Starter and Alternator
Condition: Improper/Lack of Maintenance
Due 12 February 2003
Resolved 13 February 2003
Electrical › Electrical Distribution System (service)
Issued 12 December 2002
Resolved
Install cover on starboard side main salon outlet. LEGACY COMPONENT DESC: Outlet Cover
Condition: Unknown
Due 12 February 2003
Resolved 13 February 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 December 2002
Resolved
Replace A-1 extinguisher in galley with a B-II. LEGACY COMPONENT DESC: Service
Condition: Placed in Improper Service
Due 12 February 2003
Resolved 13 February 2003
Construction/Loadline › Structures
Issued 12 December 2002
Resolved
Install a B-15 class boundary in place of the uninsulated wood bulkhead between galley and main salon. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Design Flaw
Due 12 February 2003
Resolved 24 February 2003
Resolution: Owner installed stainless steel sheating and covered all exposed wood within three feet of stove.
Fire Fighting › Structural Fire Protection - General
Issued 12 December 2002
Resolved
Do not operate stove in galley until wood bulkhead between galley and main salon is replaced. LEGACY COMPONENT DESC: Cooking Area
Condition: Placed in Improper Service
Due 12 February 2003
Resolved 24 February 2003
Communications › Internal Communications System
Issued 12 December 2002
Resolved
Install a public address system capable of reaching passengers throughout vessel. LEGACY COMPONENT DESC: P A System
Condition: Placed in Improper Service
Due 12 February 2003
Resolved 13 February 2003
Construction/Loadline › Structures
Issued 12 December 2002
Resolved
Install additional courses or equivalent on forward hand rails. LEGACY COMPONENT DESC: Main Deck Exterior Hand Rails
Condition: Design Flaw
Due 12 February 2003
Resolved 13 February 2003
Documentation › Logs/Records
Issued 12 December 2002
Resolved
Provide and maintain a training log. LEGACY COMPONENT DESC: Training Log
Condition: Placed in Improper Service
Due 12 February 2003
Resolved 13 February 2003
Lifesaving
Issued 26 April 2001
Resolved
The vsl's crew is required to demonstrate proof of being enrolled into a drug testing program. Proof should be demonstrated prior to 08May01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001
Resolved
Vsl's owner required to post signs indicating where the portable fire extinguishers are located prior to 08May01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001
Resolved
Vsl's owner required to post signs indicating number of passengers allowed on the upper deck (15) and a sign on the upper deck indicating areas where passengers are allowed. The sign shall be posted prior to boarding passengers for hire.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Accommodation/Occupational Safety
Issued 26 April 2001
Resolved
Vsl's owner has not completed the installation of all rail courses. Complete installation prior to boarding passengers for hire._x001C_
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001
Lifesaving
Issued 26 April 2001
Resolved
Vsl's owner required to mount its required ring bouy prior to 08May01.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Accommodation/Occupational Safety
Issued 26 April 2001
Resolved
Vsl's owner required to finish installing brackets on the upper deck- aft of the pilot house-prior to carrying passengers for hire.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 26 April 2001
Resolved
Vsl's port engine has an exhaust leak- repair prior to 08May01.
Condition: Unknown
Due 1 May 2001
Resolved 1 May 2001