Records from 2014 to 2026. Most recent: inspection, 8 August 2026.
Inspection history · 36
8 August 2026
COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8458070
17 June 2026
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8406989
7 March 2026
PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8318758
6 March 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8318559
29 December 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8288154
9 August 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7974018
28 April 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7902538
28 April 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7902591
13 February 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7865362
10 February 2024
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7863684
19 January 2024
Ballast Water Examination · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7851555
15 January 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7849515
8 January 2024
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7846537
17 May 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7448683
14 December 2021
MARPOL Annex VI Survey · Ballast Water Examination · PSC B · COE-Dockside · ISPS Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7367738
14 October 2021
Deficiency Check · PSC A · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7330739
13 October 2021
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7335463
24 August 2020
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7041622
26 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916199
26 December 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6879193
24 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6880291
7 November 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6846074
25 March 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6648823
25 March 2019
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6648830
4 January 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6605630
1 January 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6604427
21 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6601643
20 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6600590
7 December 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6593638
15 August 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6503224
12 June 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6173161
8 June 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6169564
16 August 2016
COE-Dockside
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5973041
12 August 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5970877
27 January 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5798582
10 March 2014
COE-Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4813468
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2021
Resolved
Ships shall be designed, constructed, and maintained in compliance with the mechanical requirements of a Classification Society which is recognized by the Administration. Ship experienced a casualty on the main propulsion system resulting in a complete shutdown of Main Propulsion during maneuvering. 74 SOLAS 2020 cons/ CH II-1 Reg 3-1.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2021
Resolution: Vessel provided objective evidence to satisfy the requirements of the deficiency to the USCG. Vessel provided a classification report attesting to proper repair and survey of the failed component.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 7 November 2019
Resolved
11122-Subject to the provisions of regulation 8.3 a satellite emergency position-indicating radio beacon (EPIRB) which shall be capable of floating free if the ship sinks and of being automatically activated when afloat. PSCO observed a life raft hydrostatic release attached to the EPIRB which stated “Hydrostatic release unit for life rafts of all capacities”. Crew could not find any documentation for the HRU verifying it could be used on a EPIRB.
74 SOLAS (a) 2014 Cons IV/7.6.6.4
17a/c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2019
Resolved 9 November 2019
Resolution: Received Class report attesting to proper HRU.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 7 November 2019
Resolved
01309- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. PSCO observed forward store had been converted to a paint locker with a sprinkler system installed. PSCO reviewed fire control plan and no modifications were found shoeing the addition of sprinkler or that the room was rated for a service space (high risk). Life raft is stored directly above this room.
74 SOLAS (a) 2014 Cons I/11(a)
17 a/c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2019
Resolved 9 November 2019
Resolution: Received class report attesting to movement of all flammable products into paint locker as the port side storage room was not approved.
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 7 November 2019
Resolved
10110- All ships of 150 GT and upwards shall, in addition to the requirements of paragraph 2.1 be fitted with a daylight signaling lamp or other means to communicated by light during day and night using an energy source of electrical power not solely dependent upon the ships power supply. PSCO observed the signaling light battery was depleted and could not meet the 2 hour requirement. 74 SOLAS (a) 2014 Cons V/19.2.2.2
17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 November 2019
Resolved 9 November 2019
Resolution: Received class report attesting to proper operation of the signaling lamp.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 November 2019
Resolved
03103- Guard Rails fitted on superstructure and freeboard decks shall have at least three courses. Fixed removable or hinged stanchions shall be fitted about 1.5m apart. PSCO observed multiple stanchions that had been ripped off the deck. ICLL annex 1/25
40a
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 November 2019
Resolved 9 November 2019
Resolution: Received class report attesting to stanchions being welded to the deck.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 November 2019
Resolved
11110- Each life raft shall be stowed with its painter permanently attached to the ship. PSCO observed the port side life raft painter D ring was not properly secured and came lose upon examination.74 SOLAS (a) 2014 Cons III/13.4.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 November 2019
Resolved 7 November 2019
Resolution: The crew placed the d-ring back in use. Class verified it was properly installed on 09NOV19
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 August 2018
Resolved
11108- Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Port state control officers found the weak link for the painter on the starboard side life raft missing. SOLAS 74(2014 CONS.) III/20.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 August 2018
Resolved 15 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 August 2018
Resolved
11131- The SOLAS training manual shall contain instructions and information on life saving appliances in the ship. Port state control offices found that the instructions for the life raft hydrostatic release did not match the brand/type installed. SOLAS 74 (2014 CONS.) III/35.3 50ab
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 12 December 2018
Resolution: MSD BROWNSVILLE received a class report from Bureau Veritas satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 August 2018
Resolved
11199 - Other (life saving)- Routes to muster stations shall be indicated with the muster station symbol, intended for that purpose, in accordance with resolution A.760(18). Found multiple escape stairway routes in the accommodation spaces with incorrect IMO symbol indicating the escape route to the lifeboat station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 12 December 2018
Resolution: MSD BROWNSVILLE received a class report from Bureau Veritas satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 June 2017
Resolved
01-0750- Doors shall be self-closing shall not be fitted with hold back hooks. Class A fire Door leading from pantry to galley had self closing device removed and hold back hook.
74 SOLAS (2014 CONS) II-2/9.4.2.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2017
Resolution: Recived Class Report attestig to proper correction of deficiency.