MAURY USCG vessel records
← All vessels

CBC 1100

CBC 1100 is a 2014 tank barge. The Coast Guard has recorded 10 inspections since 2014, most recently in May 2024, along with 2 deficiencies and 1 casualty investigation in 2019.

Records from 2014 to 2024. Most recent: inspection, 13 May 2024.

Built
2014
Last inspected
13 May 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 13 May 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2014–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1273158
Flag
UNITED STATES
Maury page id
psix-1273158

Documentation record

Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry, non-fishing vessel
DocumentationValid · issued 16 September 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DAVID A. LEWIS, JR Towing Vessel · MISLE 113937 · 4 August 2019 · activity 6773804

Inspection history · 10

13 May 2024 MTSA Verification · Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7908045
24 July 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7014794
4 August 2019 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6773804
11 April 2019 Deficiency Check · COI Inspection · MTSA Verification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6660456
9 February 2018 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6368163
24 February 2017 Periodic Inspection · MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6093998
7 April 2016 Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5852602
2 March 2016 Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5825500
21 January 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5056386
11 March 2014 Administrative Inspection · Initial Certification · Initial Construction-Excluding Oversight · MTSA Verification · Hull Examination · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4836340

Deficiency record · 2

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 April 2019 Resolved
Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Barge does not conduct testing. Provide testing evidence to the satisfaction of attending Marine Inspector prior to cargo operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2019
Resolved 9 May 2019
Resolution: Reviewed Cargo pipeline & gauges test certs. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 18 April 2019 Resolved
Each pressure gauge must show pressure within 10 percent of the actual pressure. Barge does not conduct testing. Provide testing evidence to the satisfaction of attending Marine Inspector prior to cargo operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2019
Resolved 9 May 2019
Resolution: Reviewed Cargo pipeline & gauges test certs. All sat.

Casualty record · 1

4 August 2019Routine · role: Involved in a Marine Casualty · activity 6773804
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CHEM 1204 (2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.