Records from 2015 to 2026. Most recent: inspection, 25 February 2026.
Documentation record
Registered dimensions (L × B × D)106.2 ft × 35.0 ft × 17.0 ft
Registered tonnagegross 184 / net 125
ITC dimensions (L × B × D)106.2 ft × 35.0 ft × 17.0 ft
ITC tonnagegross 434 / net 130
BuilderVT HALTER MARINE INC · ESCATAWPA, MS, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 August 2026 · expires 30 September 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it434 - Convention (Subpart B), Gross Ton
184 - Regulatory (Subpart C or D), Gross Ton
130 - Convention (Subpart B), Net Ton
125 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
25 February 2026
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8316568
5 December 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8278015
10 November 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266662
27 February 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8085870
27 February 2025
Type not recorded
No type recorded · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 8088859
22 November 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8038783
9 September 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7999299
9 September 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005098
3 May 2024
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7906014
30 August 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7781199
12 September 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7556955
21 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7483148
9 March 2022
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7408561
29 November 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358627
10 November 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348936
28 September 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7322480
1 July 2021
COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7241885
3 February 2021
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7135121
21 May 2020
COI Inspection · Administrative Inspection · Initial Certification · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6957229
10 February 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6906076
12 July 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6755392
25 June 2018
MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6454946
13 December 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6324052
3 September 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5238528
21 May 2015
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 5131407
9 March 2015
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5074022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2026
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The starboard fuel shutoff was found inoperable. Vessel must rectify prior to conducting commercial operations.
46 CFR 143.260(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 March 2026
Resolution: Recieved and uploaded ABS report attesting to repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of towing vessel safety and safety of persons on board under normal and emergency conditions.
Vessel self reported excessive smoke emmitting from their Main Diesel Engines exhaust stack. Prior to commercial operations, provide a report from the vessels Third [name withheld] attesting the vessel is fit for intended route and service. 46 CFR 143.205
Action required: 705 - Other - as specified
Due 10 November 2025
Resolved 11 November 2025
Resolution: recieved ABS report attesting to repair, see documents.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 February 2021
Resolved
46 CFR 199.130 (c)(3) Each life raft must be arranged to permit it to drop into the water from the deck on which it is stowed. Life raft on board is stowed in a alongside continuous handrail above bridge in a secured cradle which does not allow for manual release into the water from its securing arrangements. Vessel must provide a plan proposal for addressing this issue.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2021
Resolved 7 April 2021
Resolution: Liferaft launching arrangements properly installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 February 2021
Resolved
46 CFR 16.230 (k) An individual may not be engaged or employed on a vessel as master, operator or person in charge for which a credential is required without being subject to the random testing requirements of this section. There were no marine employer's drug testing records. Vessel was unable to provide a list of enrolled employees, and no records of random and pre-employment tests for the last couple years.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2021
Resolved 7 April 2021
Resolution: Verified Crew enrollment in the DAPI program.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 February 2021
Resolved
46 CFR 143.260 (b) To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shut off valve must be fitted on any fuel line that supplies fuel to engine or generator prime mover. While on board, crew was unable to located where the fuel shut off valves where resulting in the inability to witness the valves being able to close. A re-inspection with attending marine inspectors will be required for the crew to show proper closing and opening of the fuel shut off valves
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 6 April 2021
Resolved 7 April 2021
Resolution: Remote means of fuel shut-offs verified and functioning properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 May 2020
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 30 days. If an inspection is not completed prior to this date, the action for this deficiency
shall be changed to a 60 (Rectify deficiencies prior to (movement) and the vessel may no long be permitted to operate.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 June 2020
Resolved 7 April 2021
Resolution: COI inspection satisfactory completed. Issued COI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 February 2020
Resolved
The vessel currently only has a master onboard. The vessel must meet the manning requirement of one Master, one Mate, and two deckhands prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2020
Resolution: Vessel was manned correctly