Records from 2008 to 2026. Most recent: inspection, 24 February 2026.
Inspection history · 39
24 February 2026
MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8312536
28 October 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8260049
29 January 2025
MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8071380
9 September 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8005098
5 February 2024
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex II Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7860931
9 January 2023
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7618805
10 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7473437
1 December 2021
MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7327779
18 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7353789
9 July 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7250590
7 July 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7248179
8 March 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152336
12 February 2021
Deficiency Check · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7140105
2 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105092
29 October 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7086397
7 August 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7026689
1 July 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6734625
3 May 2019
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6675838
26 March 2019
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6649412
14 September 2018
MTSA Verification · Annual Inspection · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6538620
23 July 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6489438
1 February 2018
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6347997
14 July 2017
MTSA Verification · MARPOL Annex II Examination · Periodic Inspection · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212092
30 June 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6191730
15 March 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6105403
19 April 2016
Annual Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5859176
15 March 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5834219
24 September 2015
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5727435
21 August 2015
MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · MARPOL Annex II Examination · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5222589
29 May 2014
COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4878141
29 August 2013
Deficiency Check · MTSA Verification · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4700252
3 December 2012
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4495331
5 July 2012
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4367870
16 May 2012
MTSA Verification · Deficiency Check · Periodic Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4311332
2 August 2011
MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex V Examination · MTSA Verification · Annual Inspection · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4102682
21 June 2011
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4052402
15 October 2010
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3870654
23 August 2010
MARPOL Annex VI Survey · Annual Inspection · MTSA Verification · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3831954
25 November 2008
MARPOL Annex VI Survey · MTSA Verification · MARPOL Annex II Examination · COI Inspection · Deadweight Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3369135
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 January 2025
Resolved
Any Tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum one remote manual shutdown station. During remote shutdown testing of cargo pump prime mover #3 the pull cable assembly was discovered severely blocked conduit restricting the free movement of the pull cable. Similar conditions were discovered on both #1 and #2 during testing.
Action required: 10 - Deficiency Rectified
Resolved 12 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 29 January 2025
Resolved
Each lifejackets must be marked with the name of the vessel as required and the home port noted on the ring buoy. During the deck walk, several appliances were identified in needing re-stenciling lifebuoys: name of vessel/home port and ensure lifejackets only have one vessel name on them by blocking out old vessel names.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2025
Resolution: Photographic evidence received of corrected condition
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 January 2025
Resolved
Each vessel must have suitable pilot boarding equipment available for use on each side of the vessel. During the deck walk, the port side pilot ladder was discovered missing spreader boards/slats as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Photographic evidence of correction provided
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 29 January 2025
Resolved
Marpol Annex II requires every ship of 150 gross tons and above certified to carry NLS in bulk to have onboard a shipboard marine pollution emergency plan for NLS. During the review of the Shipboard oil pollution emergency plan (SOPEP) and vessel response plans (VRP) information for the carriage of NLS in bulk was not included. Provide evidence that the combined emergency plan has the required information for NLS carriage.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Objective evidence provided
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 January 2025
Resolved
During periodic inspection the OCMI will ensure the vessel is in satisfactory condition and fit for full service. During the deck walk paint was discovered in the forward deck shelter. Further, excess equipment was discovered in each of the authorized paint lockers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 February 2025
Resolution: Photographic evidence received of corrected condition
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2025
Resolved
Survival craft embarkation arrangements. Embarkation ladder storage was improperly marked "pilot ladder."
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Photographic evidence of correction provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 January 2025
Resolved
During periodic inspection the OCMI will ensure the vessel is in satisfactory condition and fit for full service. Navigation light status indicating panel was discovered without fuses, extinguished visual indicators and insufficient audible alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Photographic evidence of correction provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 February 2024
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 31.01–2) as specified in paragraphs (a)(1) through (4) of this section. Marine inspector discovered 02 semi-portable and 01 portable fire extinguishers that were past due for annual inspections/servicing. Complete Servicing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2024
Resolution: Received evidence of servicing. All sat.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Technical files and if applicable, monitoring manual
Issued 5 February 2024
Resolved
he revised NOx Technical Code 2008 shall be applied in the certification, testing, and measurement procedures for the standards set forth in this regulation.
During annual IAPP Survey, vessel crew was unable to provide EIAPP certificates and NOx Technical Files
for 03 installed cargo pump prime movers rated over 130KW - serial numbers:
ENGINE 1: RG6125H063129
ENGINE 2: RG6125H062998
ENGINE 3: RG6125H063125
Provide files for Marine Inspector review.
MARPOL 73/78 (2017) VI / 13.8
Condition: Improper/Lack of Maintenance
Action required: 702 - Prior to embarking on international voyage
Resolved 7 February 2024
Resolution: Marine Inspectors received / viewed all 03 cargo pump prime mover EIAPPs and NOx Technical files.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 9 January 2023
Resolved
The remote quick acting manual shutdown for the cargo pump engine shall be installed on the engine so as to provide a quick and effective means of stopping the engine. The remote manual shutdown for the No. 2 cargo pump engine could not be tested at the time of inspection for annual endorsement. Rectify prior to operation of No. 2 cargo pump.
46 CFR 32.50-35
Action required: 705 - Other - as specified
Resolved 13 February 2023
Resolution: All sat.
14 - Pollution Prevention › 142 - MARPOL Annex II › Other (MARPOL Annex II)
Issued 9 January 2023
Resolved
Every ship to which this Annex applies shall be provided with a Cargo Record Book. A Cargo Record Book was not available at the time of inspection. Rectify prior to the carriage of NLS.
MARPOL II/15.1
Action required: 705 - Other - as specified
Resolved 13 February 2023
Resolution: Vessel is unable to obtain Cargo Record Book due to owning unit resources. Vessel shall not carry NLS without presence of Cargo Record Book. Reissue Cargo Record Book prior to COI renewal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 January 2023
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. The watertight door leading to the forepeak compartment could not properly close and form a weathertight seal to the satisfaction of the class surveyor. Restricted to LBS until deficiency is rectified. 46 CFR 42.15-30(c)
Action required: 705 - Other - as specified
Resolved 13 February 2023
Resolution: Repaired to the satisfaction of ABS standards. All sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 December 2021
Resolved
Transfer hoses must be marked with the name of each product the hose is used for or for oil products the word "Oil Service," or for hazardous material the words "Hazmat Service-See list."...the hose must also be marked with the maximum allowable working pressure.
The transfer hoses were not marked with the type of service or the MAWP.
33 CFR 155.800
33 CFR 154.500(e), (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2021
Resolved 15 December 2021
Resolution: Received photographic evidence of proper stenciling on cargo transfer hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021
Resolved
EACH GENERATOR PRIME MOVER MUST HAVE AN OVERSPEED DEVICE THAT ENSURES THE SPEED CANNOT EXCEED THE MAXIMUM RATED SPEED BY MORE THAN 15%. ATTENDING MI WERE UNABLE TO VERIFY THE OPERATION OF THE OVERSPEED DEVICE ON GEN 1&2.
46CFR31.35-1
46CFR111.12(b)
46CFR61.20-3(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CG MI witnessed proper operation of the device.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021
Resolved
AT EACH INSPECTION FOR CERTIFICATION, THE MARINE INSPECTOR SHALL CONDUCT SUCH TESTS AND INSPECTIONS OF THE MAIN/AUXILIARY MACHINERY AS HE FEELS NECESSARY FOR SAFE OPERATION. EACH PRIME MOVER MUST SHUTDOWN AUTOMATICALLY UPON LOSS OF LUBRICATING OIL PRESSURE. MI'S WERE UNABLE TO TEST THE LOSS OF LUBE OIL GEN 1&2 SHUTDOWNS DUE TO THE CREW NOT HAVING KNOWLEDGE OF HOW TO PERFORM THE TEST.
46CFR31.35-1
46CFR111.12-1(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CG MI witnessed proper operation of the shutdown.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 12 February 2021
Resolved
ALL US FLAGGED VESSELS ENGAGED IN DOMESTIC VOYAGES BY SEA ARE APPLICABLE TO THIS PART. VESSEL REQUESTED AN OCEANS ROUTE COI AND DOES NOT HAVE A VALID LOADLINE/LOADLINE CERTIFICATE. LOADLINE TO BE FOR MANNED VSL, DUE TO THE CREW STAYING ON THE BARGE, EVEN ON OCEAN VOYAGES.
46CFR31.25-1
46CFR42.03-5(b)(1)
VESSEL RESTRICTED TO OPERATIONS WITHIN THE BOUNDARY LINE.
Action required: 705 - Other - as specified
Resolved 31 March 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 February 2021
Resolved
AT EACH INSPECTION FOR CERTIFICATION, THE STRUCTURE MUST
BE INSPECTED. THE DECK AREA AFT OF THE PORT MANIFOLD AND
UNDERNEATH THE STBD PUMPROOM ARE PITTED. DESCALE AND PERFORM UT SHOTS OF THESE AREAS.
46CFR31.10-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2021
Resolution: Witnessed final vacuum box test of the welded plate insert, and inspected clad welds in marked pits. All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 February 2021
Resolved
THERE MUST BE GROUND DETECTION FOR EACH LIGHTING SYSTEM AND POWER AND LIGHTING DISTRIBUTION SYSTEM. THE GROUND DETECTION PANEL LIGHTS WERE NOT CAPABLE OF LIGHTING AND THE MI WAS UNABLE TO VERIFY PROPER OPERATION.
46CFR31.35-1
46CFR111.05-21
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CG MI witnessed proper operation of the device.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 February 2021
Resolved
NON-METALLIC FLEXIBLE HOSE (SAE J1942) MAY BE USED IN LENGTHS NOT EXCEEDING 30-INCHES. ALL OF THE ENGINES/PRIME MOVERS ON THE VESSEL HAD FLEXIBLE HOSES THAT WERE IN EXCESS OF 30-INCHES AND WERE CHAFED.
46CFR31.30(a)
46CFR56.60-25(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CGMI received documentation for the approved hoses and witnessed them in place on the generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021
Resolved
AT EACH INSPECTION FOR CERTIFICATION, THE MARINE INSPECTOR SHALL CONDUCT SUCH TESTS AND INSPECTIONS OF THE MAIN/AUXILIARY MACHINERY AS HE FEELS NECESSARY FOR SAFE OPERATION. GENERATOR 3 WAS TAGGED OUT BY THE CREW DUE TO THE INABILITY TO MAINTAIN RUNNING OPERATION OF THE PRIME MOVER. A TECH REPORT OR CG [name withheld] IS TO BE APPROVED, PRIOR TO UTILAZTION OF THE GENERATOR SYSTEM.
46CFR31.10-15
46CFR31.35-1
46CFR111.12-1(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CG MI witnessed proper operation of the device/shutdowns.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 February 2021
Resolved
OCEAN GOING VSLS SHALL COMPLY W/SUB CH W. THE VSL DID
NOT HAVE THE REQ. RING BUOYS AND FLOATING WATERLIGHTS. VESSEL NOT TO OPERATE OUTSIDE THE BOUNDARY LINE UNTIL THE REQUIRED ITEMS ARE ON BOARD AND IN SERVICE.
46CFR31.36-1
46CFR199.10
Action required: 705 - Other - as specified
Resolved 21 April 2021
Resolution: vessel had required number of lifebuoys onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 February 2021
Resolved
AT EACH INSPECTION FOR CERTIFICATION, THE MARINE INSPECTOR SHALL CONDUCT SUCH TESTS AND INSPECTIONS OF THE MAIN/AUXILIARY MACHINERY AS HE FEELS NECESSARY FOR SAFE OPERATION. THE REAR MAIN SEAL ON GENERATOR 1 WAS LEAKING A SIGNIFICANT AMOUNT OF OIL.
46CFR31.10-15(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2021
Resolution: CG MI verified leak had been stopped and reviewed servicing paperwork.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 February 2021
Resolved
AT EACH INSPECTION FOR CERTIFICATION, THE STRUCTURE MUST
BE INSPECTED. THE FLANGE FOR THE STARBOARD BALLAST PUMP/LINE WAS CORRODED BEYOND USAGE.
46CFR31.10-15
Due date extended to next credit DD.
Action required: 705 - Other - as specified
Due 20 May 2021
Resolved 18 November 2021
Resolution: Upon resinspection, MIs were unable to find associated def.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 February 2021
Resolved
VESSELS CARRYING BENZENE CARGOES SHALL HAVE A BENZENE MONITORING PROGRAM. THE MI WAS UNABLE TO VERIFY THE PRESENCE OF THE BENZENE MONITORING PROGRAM.
46CFR197.501
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2021
Resolution: Copy of benzene plan verbiage was submitted by the company rep
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 February 2021
Resolved
ONBOARD TRAINING, DRILLS, AND MUSTERS MUST BE IN ACCORDANCE WITH SUB CH. W. THE VESSEL DID NOT HAVE TRAINING LOGGED BETWEEN APRIL 2020 AND DEC 2020.
46CFR35.10-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2021
Resolution: Drill documents submitted to MI.
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 1 July 2019
Resolved
Every ship to which this Annex applies shall be provided with a Cargo Record Book, whether as part of the ship's official logbook or otherwise, in the form specified in Appendix II of this Annex. Vessel did not have Cargo Record book for the carriage of NLS cargoes.
MARPOL, Annex II, Regulation 15.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 10 July 2019
Resolution: Vessel representative provided new copy of cargo record book to vessel.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2019
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station.
#2 Cargo pump engine failed to start and was not able to perform operational test of emergency shutdown.
46CFR32.50-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 10 July 2019
Resolution: Maintenance was performed on cargo pump engine, Barge PIC started engine and performed satisfactory operational test of emergency test.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 1 July 2019
Resolved
The test fluid used for the testing required by this section is limited to liquids that are compatible with the hose tube as recommended by the hose manufacturer. Cargo hose testing was performed by pressurizing the system with inert gas not a liquid.
33CFR156.170(e)
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 August 2019
Resolved 10 July 2019
Resolution: Caddell's shipyard performed hydro test on cargo hoses and provided certificate attesting to the satisfactory performance of cargo hoses.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 July 2019
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet.
FCC Station Authorization Certificate expired 29MAY2019.
47CFR80.13(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 10 July 2019
Resolution: Vessel provided proof of application to renew certificate. Image has been uploaded to documents tab in MISLE.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 1 July 2019
Resolved
All records required to be maintained by this section must be made available upon request to the Coast Guard. Vessel representative did not provide any plan or documentation for Benzene Monitoring Program.
46CFR197.570(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 10 July 2019
Resolution: Vessel representative issued a SMS major non-confomity to the vessel and provided documentation outlining the development of a new fleetwide Benzene Program. Provided temporary manual to vessel for guidance on Benzene operations.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 July 2019
Resolved
No more than 55 gallons of combustible liquids may be stowed in any machinery space. Vessel is storing more than 55 gallons of oil in port cargo pump engine machinery space.
46CFR147.45(d)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2019
Resolved 10 July 2019
Resolution: Combusible liquids were reduced to a compliant level in accordance with regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 1 July 2019
Resolved
Line throwing appliance; a drill must be conducted on the use of the line throwing appliance at once every 3 months. The actual firing of the appliance is at the discretion of the master. Line throwing applaince training is not being performed and not recorded.
46CFR199.180(e)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2019
Resolved 10 July 2019
Resolution: Barge PIC provided copies of drill conducted 03JUL2019, and has included line throwing appliance to drill schedule for emergency equipment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 September 2018
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device rom the referenced ground. Inspection resulted w/the 240V Main Electrical Panel's ground detection was displaying a faulty ground to the L3. Diagnose and repair accordinbgly to the satisfaction of a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2018
Resolved 19 November 2018
Resolution: Repairs were completed to the satisfaction of the attending Marine Inpsector. CG-835V defs cleared. Vessel is authorized back in-service.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 14 July 2017
Resolved
Drain plug's flame screen was missing on the #4S P/V Valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 July 2017
Resolution: Flame screen was replaced during the inspection.
Documentation › Certificates/Documents › Engine IAPP Certificate
Issued 14 July 2017
Resolved
EIAPP Certificate and NOX Tech files were not onboard
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 July 2017
Resolution: Certificates and files placed onboard.
Operations/Management › Drills/Instruction › Fire
Issued 14 July 2017
Resolved
Monthly fire and abandon ship drills were not being conducted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 July 2017
Resolved 17 July 2017
Resolution: Drills were conducted and logged by crew.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 21 August 2015
Resolved
Remove Inoperable 125 Dry Chemical extinguisher from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 24 September 2015
Resolution: Dry Chem inoperable extinguisher removed from vessel.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 21 August 2015
Resolved
Install sea rails on stove.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 24 September 2015
Resolution: Sea rails installed.
Documentation › Safety Management System › Master's Authority/Responsibility Documentation
Issued 21 August 2015
Resolved
Provide original safety management certificate.
Action required: 705 - Other - as specified
Due 10 October 2015
Resolved 24 September 2015
Resolution: Original safety managemnet certificate provided.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 21 August 2015
Resolved
Remove urine bucket from machinery space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2015
Resolved 26 August 2015
Resolution: Removed bucket
Lifesaving › Lifebuoys › Serviceable
Issued 29 May 2014
Resolved
Hard shell foam filled life buoy missing a plug, allowing water to enter. 46 CFR199.70
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Resolution: Owner replaced life buoy.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 29 May 2014
Resolved
#2 STBD cargo tank ullage opening flame screen holed. 46 CFR 32.60
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Resolution: Owner replaced flame screen.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 29 May 2014
Resolved
All three generators coated with excesive oil. 33CFR160
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Resolution: Owner cleaned all oil generators.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 May 2014
Resolved
Flammable liquids stored in line lockers, in forward house and in generator room. 46CFR92.07
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2014
Resolution: Owner properly stowed or removed all hazmat.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 29 May 2014
Resolved
Supplies and HAZMAT stored on top of electrical distribution panel. 33 CFR 160.
Action required: 705 - Other - as specified
Resolved 19 June 2014
Resolution: Owner removed all items stored on distribution panel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 August 2013
Resolved
Emergency lighting provide by battery operated lantern bulb is out.
Due 13 September 2013
Resolved 11 September 2013
Resolution: Emergency light was repaired by electrician.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 August 2013
Resolved
Vessel stern amber flashing light is out.
Due 13 September 2013
Resolved 11 September 2013
Resolution: Electrician made repairs and replaced stern amber flashing light.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 29 August 2013
Resolved
Vessel does not have an approved VOC management Plan.
Due 30 September 2013
Resolved 6 September 2013
Resolution: Received email from company with copy of VOC Management Plan approval letter. Plan approved 06SEP2013. Copy of letter has been uploaded to MISLE.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 16 May 2012
Resolved
Need line throwing devices on board.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 5 July 2012
Resolution: Received evidence of LTA on board vessel.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 16 May 2012
Resolved
Need Bunkder delivery notes.
Action required: 705 - Other - as specified
Due 16 May 2012
Resolved 16 May 2012
Resolution: Issued bunker note delivery example. Informed to ensure bunkers are received with bunker notes as well.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 16 May 2012
Resolved
Demonstrate proper lube oil/over speed trips on generators.
Action required: 705 - Other - as specified
Due 16 June 2012
Resolved 30 May 2012
Resolution: Received letter from company verifying correct over-speed and lube oil shut downs are installed.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 23 August 2010
Resolved
Vessel did not have IAPP Technical File for cargo pump engines. Provide a a copy of the IAPP technical file for the cargo pump engines.
Action required: 705 - Other - as specified
Due 23 September 2010
Resolved 3 September 2010
Resolution: Operator provided technical files for cargo pump engines.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 August 2010
Resolved
There is no record of Coast Guard inspection of the Class II, 80 gallon air receiver in the machinery space. Air receiever was recorded in MISLE details for this vessel, however, no inspection dates were recorded and the pressure vessel is not documented on the COI. Provide a manufacturers data report (U-1A) for the air receiver.
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 1 October 2010
Resolution: Received U-1A Manufacturers Data Report for the air receiver. A subsequent CG-835 was issued to provide additional information.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 23 August 2010
Resolved
Provide approved plans for the air receiver, serial #217271 certified by a registered professional engineer in accordance with 46 CFR 54.01-5(e). In addition, provide a copy of the shop test and inspection report to determine what tests and inspections were conducted on the pressure vessel and what subsequent tests and inspections will be required.
Action required: 705 - Other - as specified
Due 31 October 2010
Resolved 5 October 2010
Resolution: Vessel rep provided a Miscellaneous Survey Report from ABS stating that the UPV was hydrostatically tested to 300 psi.