Records from 2013 to 2026. Most recent: inspection, 20 April 2026.
Documentation record
Registered dimensions (L × B × D)75.6 ft × 34.6 ft × 5.4 ft
Registered tonnagegross 76 / net 76
ITC dimensions (L × B × D)75.6 ft × 34.6 ft × 5.4 ft
ITC tonnagegross 114 / net 65
BuilderBASIC MARINE INC · ESCANABA, MI, UNITED STATES · built 2014
Hull materialSteel
PropulsionNone
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
114 - Convention (Subpart B), Gross Ton
76 - Regulatory (Subpart C or D), Net Ton
65 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 31
20 April 2026
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8352871
2 April 2026
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8340812
13 June 2025
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8161038
30 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8148417
3 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8104311
18 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8095468
11 June 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7932386
20 March 2024
Administrative Inspection · DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7882566
26 September 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7796445
28 April 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7677764
5 April 2023
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7662976
5 May 2022
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7445289
5 May 2022
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7447620
4 March 2022
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7404502
3 March 2022
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7405449
4 March 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7150909
11 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7038061
4 April 2019
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6651453
23 October 2018
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6572704
2 March 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6364889
25 May 2017
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6155084
15 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088765
23 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5980617
16 June 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5912939
14 April 2016
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5853922
26 August 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5226158
16 July 2015
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5186138
10 June 2015
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5153803
25 June 2014
MTSA Verification · MARPOL Annex IV Survey · DAPI Audit · Initial Certification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4901015
18 June 2014
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4892105
20 December 2013
Drydock Exam · Initial Construction-Excluding Oversight · Deadweight Survey · Internal Structural Exam · Construction Oversight
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4791287
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 2 April 2026
Resolved
O/O SHALL BE PREPARED TO CONDUCT TESTS OF ALL VALVES IN FUEL LINES BY OPERATING LOCALLY AND AT REMOTE OPERATING POSITIONS. REMOTE FUEL OIL SHUTOFF VALVES FOR TUG PROPULSION ENGINES IS NOT FUNCTIONING CORRECTLY.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2026
Resolution: Local OCMI witnessed satisfactory testing of remote fuel oil shutoff valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 April 2026
Resolved
ELECTRICAL EQUIPMENT ON VESSEL MUST BE INSTALLED TO PROTECT FROM ELECTRICAL HAZARDS INCLUDING FIRE AND ELECTIRCAL SHOCK. ADDRESS THE FOLLOWING:
1.) REPLACE COVER PANEL ON REFER SYSTEM IN REFER FLATS SPACE.
2.) IN LAZARETTE SPACE, SEWAGE PUMP ELECTRICAL BOX IS MISSING KNOCK-OUT HOLE AND POWER CABLE IS PULLED OUT OF STUFFING TUBE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2026
Resolved 20 April 2026
Resolution: Cover panel for refer system was replaced and sewage pump electrical connections have been completed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 April 2026
Resolved
EACH FLOATING WATERLIGHT MUST BE APPROVED AS PER 46 CFR 161.010 SUBCHAPTER Q. WATERLIGHT ON VESSEL HAS INCORRECT BATTERY TYPE INSTALLED. INSTALL CORRECT BATTERY.
Action required: 10 - Deficiency Rectified
Resolved 2 April 2026
Resolution: Vessel installed correct batteries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 June 2025
Resolved
The main steering gear and rudder stock must be capable of moving the rudder from 35* on either side side to 35* on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed. The vessel lost steering while underway with 43 pax. troubleshoot and repair the steering system.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 June 2025
Resolved 13 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 March 2024
Resolved
Cable and wire for power and lighting circuits must: (2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable.
Cables from generators to batteries on both port and starboard generators were found to be welding cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 6 May 2024
Resolution: Received photos from [name withheld] showing marine cables installed between generators and batteries.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Vessel first-aid kit medicines were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 5 April 2024
Resolution: New first aid kit is on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 5 April 2023
Resolved
Anchor up forward is damaged/cracked anchor system was found seized and not ready for timely deployment. Ensure anchor system is ready for deployment and repair or replace damaged anchor.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 28 April 2023
Resolution: Anchor has been repaired, ready for deployable operation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 April 2023
Resolved
Tow vessel lazarette space high water alarm is not operational. Prove proper operation of high water alarm in this space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 28 April 2023
Resolution: Tow vessel lazarette space high water alarm was tested to satisfaction of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 March 2021
Resolved
Time delay for CO2 system failed test. Repair of replace time delay and re-test to the satisfaction of the attending marine inspector.
Vessel is not authorized to carry passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2021
Resolution: Vessel has corrected and tested time delay to the satisfaction of Marine Inspector. Vessel authorized to carry passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2019
Resolved
A vessel must have one or more ring life buoys in condition made ready for use. 03 life ring bouys were worn with deteriorated grab lines. Replae to the satisfaction of attending marine inspector.
46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2019
Resolved 2 May 2019
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 March 2018
Resolved
Fire Fighting service report not available.
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 2 March 2018
Resolution: Fire fighting service report email to MSU
Stability › Watertight Integrity › General
Issued 2 March 2018
Resolved
#2 void hatch gasket had deteriorated, renew gacket.
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 2 March 2018
Resolution: Gasket renewed.
Engineering › Bilge Water Management System › Strainer
Issued 14 April 2016
Resolved
#2 void bilge strainer does not operate as designed. Repair or replace to satisfaction of Marine Inspector. 46 CFR 119.510, 46 CFR 56.50-50(g)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 16 June 2016
Resolution: New strainer basket installed.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 14 April 2016
Resolved
Demonstrate to Marine Inspector that fixed water sprinklers in snack/bar area will operate as designed after installation of metal hanging doors used to secure snack/bar area. Verify system is installed accordance with Sprinkler Plan (Drawing # 522-21B). 46 CFR 118
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 16 June 2016
Electrical › Lighting (service) › Lighting Fixture
Issued 14 April 2016
Resolved
Lighting fixture damaged.
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Lighting fixture repaired prior to completion of inspection.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 June 2015
Resolved
Remove daisy chained outlet multipliers from the stereo/pa system per 46 CFR 120.200
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 16 July 2015
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 10 June 2015
Resolved
Prove air horn air reciever is ASME certified per 46 CFR 119.330
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 July 2015
Resolved 16 July 2015