Records from 2014 to 2026. Most recent: inspection, 3 June 2026.
Documentation record
Registered dimensions (L × B × D)551.4 ft × 78.0 ft × 42.0 ft
Registered tonnagegross 12,551 / net 12,551
ITC dimensions (L × B × D)551.4 ft × 78.0 ft × 42.0 ft
ITC tonnagegross 14,064 / net 8,971
BuilderDONJON SHIPBUILDING LLC · Erie, PA, UNITED STATES · built 2016
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT EVERGLADES, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8971 - Convention (Subpart B), Net Ton
12551 - Regulatory (Subpart C or D), Gross Ton
12551 - Regulatory (Subpart C or D), Net Ton
14064 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
3 June 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8390546
28 October 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8260037
7 March 2025
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8092482
3 March 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8087549
19 February 2025
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8081248
19 February 2025
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8082445
14 December 2024
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8048422
16 September 2024
MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7995924
30 July 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7970338
19 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7962218
10 June 2024
Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7931825
6 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7804685
5 September 2023
Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7785414
1 March 2023
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7644518
18 November 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7596539
20 October 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7580812
10 February 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7394487
3 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7344474
9 August 2021
Internal Structural Exam · In-Service Inspection · Examination of Repairs · Administrative Inspection · Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7235530
14 May 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199186
20 October 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7081427
27 August 2019
Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6790795
8 March 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638369
5 November 2018
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6578142
10 August 2018
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6512950
10 February 2018
Welding Related Inspections Qualification Testing · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6354562
8 November 2017
MARPOL Annex II Examination · MTSA Verification · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6306481
28 October 2016
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6034800
17 January 2014
Deadweight Survey · MTSA/ISPS Verification · COI Inspection · Construction Oversight · Administrative Inspection · Deficiency Check · VRP Review · In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4795271
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 20 February 2025
Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Complete temporary repairs of the damaged area sustained to the barge on the forward starboard side IWO starboard ballast tank 1, as approved, prior to departure from Sector Maryland-NCR AOR.
46 CFR 31.10-25
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2025
Resolution: Vessel made satisfactory temp repairs to the 1 starboard ballast tank. Class report received clearing the vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2025
Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant.
Provide a repair proposal/plan for the damage sustained to the barge on the forward starboard side IWO tank 1 Starboard Ballast from the allision at BWC Pier 10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2025
Resolution: Vessel provided satisfactory repair proposal for temp repairs to vessels hull while in Baltimore.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2025
Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be made without the approval of the Commandant. Provide a repair proposal to the cognizant OCMI for permanent repair of the damage sustained to the barge on the forward starboard side IWO starboard ballast tank 1, once approved, complete permanent. 46 CFR 31.10-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 8 March 2025
Resolution: Received satisfactory Class ABS report attesting to the satisfactory repiars of the through hull penatration.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 June 2024
Resolved
Each Type I and II barge hull must have a watertight weather deck. Cable penetration on deck that goes into the chain locker and cable penetration in chain locker that exits into fore peak are not water tight. There are rust stains exiting the cable penetration in the fore peak that show evidence of water intrusion.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 July 2024
Resolved 19 July 2024
Resolution: Received ABS report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 September 2023
Resolved
The conditions of the ship and it’s equipment shall be maintained to conform with the provisions of the code to ensure the shop will remain fit to proceed to sea without danger to the ship or persons on board or without presenting an unreasonable threat of harm to environment.
Multiple tank wash opening flange blanks on cargo deck observed as leaking by gaskets. Repair/adjust as required to maintain vapor tight integrity.
IBC Code 1.5.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 6 October 2023
Resolution: Butterworth plates received new gaskets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 September 2023
Resolved
Unless otherwise authorized by the Commandant, each ballast water management system (BWMS) must be designed and constructed in a manner that is robust and suitable for working in the shipboard environment and adequate for its intended service.
Holed/damaged ballast water piping currently repaired
with soft patch, soft patch leaking water at time of
inspection. Complete permanent repairs as originally
configured.
46 CFR 162.060-20(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 October 2023
Resolved 6 October 2023
Resolution: Technician attended and repaired minor leak in ballast pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2021
Resolved
Each generator must meet the applicable requirements for construction and testing in section 4-8-3 of the ABS Steel Vessel Rules.
MI found nameplate on #1 generator to be illegible.
46CFR31.35-1 & 46CFR111.12-5 & ABS Rules 4-8-3/3.11.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: The operator replaced the missing data plate with an approved data plate from the generator manufacturer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2021
Resolved
Pressure vessels shall be stamped with the information of this part.
MI discovered data plate on nitrogen pressure vessel was missing.
46CFR32.35-1 & 46CFR54.10-20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 November 2021
Resolved 3 November 2021
Resolution: The operator replaced the missing data plate with an approved data plate for the pressure vessel.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 8 November 2017
Resolved
The CuNi pipe on the fifi foam line is corroded and has holes, after attempting to weld the line, the decision has been made to modify the pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 10 February 2018
Resolution: Examined permanent repairs and tested equipment.All satisfactory. Cleared difficiency.