SEA POWER

SEA POWER is a 2016 towing vessel. The Coast Guard has recorded 43 inspections since 2014, most recently in July 2026, along with 15 deficiencies, 1 operational control and 7 casualty investigations between 2016 and 2025.

Records from 2014 to 2026. Most recent: inspection, 30 July 2026.

Built
2016
Last inspected
30 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 30 July 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2014–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9762352
WDI6117
1379836
Flag
UNITED STATES
Maury page id
psix-1379836

Documentation record

Registered dimensions (L × B × D)135.4 ft × 46.9 ft × 26.0 ft
Registered tonnagegross 1,175 / net 799
ITC dimensions (L × B × D)135.4 ft × 46.9 ft × 26.0 ft
ITC tonnagegross 1,317 / net 395
BuilderBAE SYSTEMS SOUTHEAST SHIPYARDS JACKSONVILLE LLC · JACKSONVILLE, FL, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT EVERGLADES, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 October 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it395 - Convention (Subpart B), Net Ton
799 - Regulatory (Subpart C or D), Net Ton
1317 - Convention (Subpart B), Gross Ton
1175 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEA CHEM-1 Tank Barge · MISLE 1276369 · 19 February 2025 · activity 8082445HOVDEN SPIRIT Tank Ship · MISLE 1216858 · 14 December 2024 · activity 8048422SEA CHEM-1 Tank Barge · MISLE 1276369 · 14 December 2024 · activity 8048422SOLAR RUBA Tank Ship · MISLE 1706024 · 14 December 2024 · activity 8048422SEA CHEM-1 Tank Barge · MISLE 1276369 · 28 October 2016 · activity 6034800

Inspection history · 43

30 July 2026 Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8450627
28 October 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8259563
18 September 2025 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8237200
19 February 2025 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8082445
14 December 2024 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8048422
22 November 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8038612
16 September 2024 MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7995904
7 September 2024 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7998319
6 September 2024 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7997612
6 September 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7997906
30 July 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7970332
30 July 2024 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7970595
25 June 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7941860
28 May 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7922092
24 May 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918573
3 November 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7821292
5 September 2023 ACP Annual Oversight · Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7785410
15 April 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7669109
20 October 2022 Annual Inspection · ACP Annual Oversight
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7580803
20 July 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7511643
20 July 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7511685
5 May 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7444646
15 February 2022 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7396800
9 August 2021 In-Service Inspection · Internal Structural Exam · Examination of Repairs · Administrative Inspection · ACP Handover Survey · MTSA/ISPS Verification · Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7235926
13 July 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7255759
8 April 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7170782
21 October 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7084555
24 July 2020 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7015089
24 July 2020 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7023505
20 November 2019 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6859390
5 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6804933
27 August 2019 Internal Structural Exam · Periodic Inspection · MTSA/ISPS Verification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6790788
18 August 2019 Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6787855
12 August 2019 Administrative Inspection · Underwater Inspection in lieu of Drydock
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6791353
13 December 2018 In-Service Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6597447
13 November 2018 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6587359
16 January 2018 Damage Survey
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6338481
8 November 2017 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6302693
8 November 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6354981
29 October 2016 Deficiency Check · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6031586
28 October 2016 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6034800
17 October 2016 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6028320
12 November 2014 Administrative Inspection · MTSA/ISPS Verification · Construction Oversight · Plan Review (Other than "T") · Inclining Experiment · Damage Survey · Initial Certification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5022262

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2024 Resolved
A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. MI found secondary source of starting the emergency diesel generator inoperable. Vessel is restricted from operations until verified completed by the attending USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2024
Resolved 18 September 2024
Resolution: Witnessed proper operation of secondary start. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2024 Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel is currently operating with one generator because of suspected water contaminated fuel. Fix to the satisfaction of Class/RO and the Coast Guard prior to departing the Miami COTP Zone. SOLAS 20 II-1/41.1.1
Action required: 15 - Rectify deficiencies by next port
Due 15 September 2024
Resolved 7 September 2024
Resolution: Received ABS Report. Replaced twelve (12) injectors: John Deere Part #: RE529149. Switched fuel supply. Chief Engineer demonstrated load sharing and generator paralleling. No alarms present at the time of testing. All test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2020 Resolved
All marine engineering detail such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed IAW with the provisions of sub chapter F (Marine Engineering). Power-operated main and auxiliary steering gear must be separate systems that are independent throughout their length. The main steering gear and rudder stock must be capable of moving the rudder from 35 degrees on either side to 35 degrees on the other with the vessel at its deepest loadline draft and running at maximum ahead service speed, and from 35 degrees on either side to 30 degrees on the other in not more than 28 seconds under the same consideration. Duty MIs received a report that the starboard rudder did not respond to helm control and was hard over port. The auxiliary system was able to bring the rudder back to 10 degrees port. The C/E determined the forward ram was discharging h/o within the ram. Conduct permanent repairs to the steering gear system to the satisfaction of the US Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 July 2020
Resolved 30 July 2020
Resolution: Steering ram was replaced and a satisfactory test was witnessed by ABS surveyor.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 August 2019 Resolved
The boundary bulkheads and decks separating the accommodation and control stations from machinery spaces shall be of "A" class construction. The following areas do not meet structural fire boundary requirements: 1) cable penetrations on 02 deck; 2) cable penetrations on 03 deck (2 locations); 3) cable penetrations on aft bulkhead of locking pin room; 4) aft bulkhead of main deck HVAC room around piping; 5) engine room overhead over main engines. 46 CFR 92.07-10(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 9 September 2019
Resolution: Received objective evidence showing SFB materials are in place.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 27 August 2019 Resolved
Periodic Safety Test Procedures described in 46 CFR 61.40 must be submitted to the Coast Guard and approved. There is no objective evidence that the PSTPs were approved by the CG. Correspondence from MSC dated 01SEP17 indicates the PSTPs were accepted pending onboard testing by the OCMI. The onboard testing by the OCMI was not completed. 46 CFR 62.20-1(a)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2019
Resolved 5 September 2019
Resolution: Witnessed testing of the Periodic Safety Test Procedures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 August 2019 Resolved
Maintenance of service necessary for the safety under normal and emergency conditions. Ship service generator has suffered unknown failures. vessel shall make permanent repairs to the satisfaction of attending Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2019
Resolved 28 August 2019
Resolution: Harbor generator was rebuilt and tested by marine inspector and found in good working order.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 January 2018 Resolved
Radar inop due to heavy weather.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 January 2018
Resolved 19 January 2018
Resolution: Recvd tech report from Radio Holland of repairs to the 10CM radar. All Sat.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 8 November 2017 Resolved
Properly repair leak for Fire Monitor water supply line (FIFI). Weld located on piping at bulkhead penetration in srore room 6717 on main deck. Permament repair to be verified to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 10 February 2018
Resolution: Examined permanent repairs/modifications. All Sat. Witnessed system operation and no discrepancies were noted. Cleare CG835. No other deficiencies remain.
Electrical › Electric Generation Source (service) › Generator
Issued 29 October 2016 Resolved
Vessel required to prove proper operating of generator sets prior to operating.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 October 2016
Resolution: Vessel provided ABS class survey clearing v3essel for operations.
Lifesaving › Lifebuoys › Stowage
Issued 15 August 2016 Resolved
Demonstrate bridge buoys release with tug in the notch (Dual Mode Sea Trials) before departing Erie, PA.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2016
Operations/Management › Navigation Safety › Navigation Underway, Towing Vessels
Issued 15 August 2016 Resolved
Demonstrate "Dual Mode" tug capacity for emergency towing.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2016
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 August 2016 Resolved
Ensure self closing device on WTD/Fire door leading from the machinery space to the steering gear room is properly adjusted.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 October 2016
Resolved 26 October 2016
Resolution: Inspected WTD closure satisfactorily
Operations/Management › Vessel Activity › Underway
Issued 15 August 2016 Resolved
Prove proper operation of the Intercon System with tug in notch prior to sailing from Erie, PA.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2016
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 August 2016 Resolved
Make appropriate pen and ink changes to Fire Safety Plan and submit for review/approval by USCG or ABS.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 October 2016
Resolved 19 October 2016
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 12 November 2014 Resolved
Provide as built, all apporved USCG FMEA/DVTP for relevant shipboard systems.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 September 2017

Casualty record · 7

28 October 2016Routine · role: Involved in a Marine Casualty · activity 6034800
24 July 2020Routine · role: Involved in a Marine Casualty · activity 7023505
20 July 2022Routine · role: Involved in a Marine Casualty · activity 7511685
3 November 2023Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7821292
6 September 2024Routine · role: Involved in a Marine Casualty · activity 7997612
14 December 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 8048422
19 February 2025Routine · role: Involved in a Marine Casualty · activity 8082445
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.