Records from 1996 to 2025. Most recent: inspection, 11 September 2025.
Documentation record
Registered dimensions (L × B × D)42.6 ft × 14.5 ft × 6.9 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · SOMERSET, MA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ7439MMSI 368452850 · active · compulsorily equipped · granted 15 January 2026, expires 15 January 2036
WDJ9442MMSI 368026090 · active · compulsorily equipped · granted 8 March 2018, expires 8 March 2028 · licensed under a name not among this hull’s recorded names (not shown)
WDG3579MMSI 367527480 · expired · compulsorily equipped · granted 26 April 2012, cancelled 2 July 2022 · licensed under a name not among this hull’s recorded names (not shown)
WCZ4563MMSI 367415740 · cancelled · compulsorily equipped · granted 19 June 2009, cancelled 7 May 2012 · licensed under a name not among this hull’s recorded names (not shown)
WTT2862MMSI not assigned · expired · compulsorily equipped · granted 12 August 1996, cancelled 16 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s
MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 17
11 September 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8231528
14 May 2024
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7909822
27 February 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870928
12 September 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790359
8 November 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7591571
13 October 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7576557
30 September 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7323649
27 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7116652
30 June 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6991265
22 June 2020
COI Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6983776
14 February 2020
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912348
27 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6524405
21 July 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5192658
26 April 2012
DAPI Audit · Industry Initiated Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4295716
17 February 2012
Administration
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246405
19 August 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 432315
5 January 1996
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 386769
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2024
Resolved
A towing vessel must carry adequate and up-to-date charts. The vessel does not have up-to-date paper charts nor approved and updated electronic charts. Rectify to the satisfaction of USCG prior to vessel movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2024
Resolution: Vessel provided OQE of updated electronic charts and a declaration of conformity for the electronic charting system to the satisfaction of the USCG MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 May 2024
Resolved
Fire-detection systems must be inspected or tested at least once every twelve months. The most recent onboard documentation for servicing of the fire detection system was from 2020. Rectify to the satisfaction of USCG prior to commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: Servicing company's report attesting to completion of satisfactory annual inspection provided by owner.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 May 2024
No resolution recorded
Each towing vessel must be equipped with a marine radar. The upper wheelhouse radar repeater is non-functioning. Functional repeaters are located in the lower wheel house. Vessel is required to maintain a watch in the lower wheelhouse any time that the upper wheelhouse is being used for movement of the vessel. Rectify to the satisfaction of USCG prior to resuming any operations from the upper wheelhouse without the lower wheelhouse manned.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 May 2024
No resolution recorded
A towing vessel must be outfitted with a fire detection control panel at the operating station. On a towing vessel with more than one operating station, only one operating station must be outfitted with a fire detection control panel. Any other operating station must be outfitted with either a fire detection control panel or remote indicator panel. The vessel does not have a fire detection control panel or remote indicator panel located in the upper wheelhouse. Vessel is required to maintain a watch in the lower wheelhouse any time that the upper wheelhouse is being used for movement of the vessel. Rectify to the satisfaction of USCG prior receiving credit for next drydocking and prior to resuming any operations from the upper wheelhouse without the lower wheelhouse manned.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024
Resolved
"A COI may be suspended and withdrawn or revoked by the cognizant Officer in Charge, Marine Inspection at any time for noncompliance with the requirements of this subchapter." COI was revoked for not completing annual inspection within the required window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Vessel attended for COI. Inspectin completed and temporary COI issued
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 September 2023
Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals:
(1) A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Inspection not completed within the required time frame.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2035
Resolved 7 March 2024
Resolution: Issued credit dry dock
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2022
Resolved
143.400 (g) Electrical components that pose an electrical hazard must be in an enclosure. Exposed wiring found at generator switch on fwd bulk head in ENG room. Secure exposed wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Operator sent photograph of wire secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2022
Resolved
143.400 (f) Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments.
143.400 (i) The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation.
Bilge pump plugged into overhead horizontal outlet with excess wire able to reach the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Operator sent photograph of electrical connection secured.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018
Resolved
Vsl is broadcasting: Invalid Call Sign, no static draft information, and No dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 30 June 2020
Resolution: AIS REPORTED NO ERRORS, DEF CLEARED -- [name withheld]