MAURY USCG vessel records
← All vessels

CAPT KYLE

Built
1974
Last inspected
11 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 11 September 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1996–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ7439
127722
Flag
UNITED STATES
Maury page id
psix-127722

Documentation record

Registered dimensions (L × B × D)42.6 ft × 14.5 ft × 6.9 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOMERSET, MA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 22 December 2025 · expires 31 December 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NAOH Tank Barge · MISLE 43810 · 21 July 2015 · activity 5192658LIZ VINIK Towing Vessel · MISLE 79947 · 21 July 2015 · activity 5192658

Inspection history · 17

11 September 2025 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8231528
14 May 2024 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7909822
27 February 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7870928
12 September 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7790359
8 November 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7591571
13 October 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7576557
30 September 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7323649
27 December 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7116652
30 June 2020 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6991265
22 June 2020 COI Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6983776
14 February 2020 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912348
27 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6524405
21 July 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5192658
26 April 2012 DAPI Audit · Industry Initiated Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4295716
17 February 2012 Administration
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4246405
19 August 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 432315
5 January 1996 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 386769

Deficiency record · 9

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 May 2024 Resolved
A towing vessel must carry adequate and up-to-date charts. The vessel does not have up-to-date paper charts nor approved and updated electronic charts. Rectify to the satisfaction of USCG prior to vessel movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2024
Resolution: Vessel provided OQE of updated electronic charts and a declaration of conformity for the electronic charting system to the satisfaction of the USCG MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 May 2024 Resolved
Fire-detection systems must be inspected or tested at least once every twelve months. The most recent onboard documentation for servicing of the fire detection system was from 2020. Rectify to the satisfaction of USCG prior to commercial operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: Servicing company's report attesting to completion of satisfactory annual inspection provided by owner.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 May 2024 No resolution recorded
Each towing vessel must be equipped with a marine radar. The upper wheelhouse radar repeater is non-functioning. Functional repeaters are located in the lower wheel house. Vessel is required to maintain a watch in the lower wheelhouse any time that the upper wheelhouse is being used for movement of the vessel. Rectify to the satisfaction of USCG prior to resuming any operations from the upper wheelhouse without the lower wheelhouse manned.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 May 2024 No resolution recorded
A towing vessel must be outfitted with a fire detection control panel at the operating station. On a towing vessel with more than one operating station, only one operating station must be outfitted with a fire detection control panel. Any other operating station must be outfitted with either a fire detection control panel or remote indicator panel. The vessel does not have a fire detection control panel or remote indicator panel located in the upper wheelhouse. Vessel is required to maintain a watch in the lower wheelhouse any time that the upper wheelhouse is being used for movement of the vessel. Rectify to the satisfaction of USCG prior receiving credit for next drydocking and prior to resuming any operations from the upper wheelhouse without the lower wheelhouse manned.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024 Resolved
"A COI may be suspended and withdrawn or revoked by the cognizant Officer in Charge, Marine Inspection at any time for noncompliance with the requirements of this subchapter." COI was revoked for not completing annual inspection within the required window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2024
Resolution: Vessel attended for COI. Inspectin completed and temporary COI issued
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 September 2023 Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals: (1) A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Inspection not completed within the required time frame.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 November 2035
Resolved 7 March 2024
Resolution: Issued credit dry dock
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2022 Resolved
143.400 (g) Electrical components that pose an electrical hazard must be in an enclosure. Exposed wiring found at generator switch on fwd bulk head in ENG room. Secure exposed wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Operator sent photograph of wire secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2022 Resolved
143.400 (f) Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. 143.400 (i) The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Bilge pump plugged into overhead horizontal outlet with excess wire able to reach the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2022
Resolution: Operator sent photograph of electrical connection secured.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2018 Resolved
Vsl is broadcasting: Invalid Call Sign, no static draft information, and No dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 30 June 2020
Resolution: AIS REPORTED NO ERRORS, DEF CLEARED -- [name withheld]

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.