Inspection history · 68
25 August 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217342
15 July 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8186534
3 June 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8150867
23 July 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7946196
15 February 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7866526
11 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7765646
13 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7747719
7 September 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553579
16 April 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7452795
1 October 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7324778
13 March 2020
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940601
21 July 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5192658
12 May 2015
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5123422
11 May 2015
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5129351
9 May 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4007251
12 March 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3695906
3 January 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3390609
20 August 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3304214
23 November 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3104457
11 October 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3176731
13 September 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3056742
5 September 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3049382
23 August 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3041251
15 August 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3034211
29 April 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2931965
28 March 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2896692
24 January 2007
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2895104
13 September 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2777489
14 June 2005
Uninspected Other · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2390577
14 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2396883
14 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2396890
14 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2396894
14 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2404739
14 June 2005
Type not recorded
No type recorded · USCGC STURGEON BAY (WTGB 109) · USCG Northeast District (CGD-NE) · Activity 2486281
8 June 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2386484
16 August 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1901448
14 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1802570
10 April 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1774897
22 November 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1710913
2 June 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1626187
2 April 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599960
26 November 2001
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1076354
21 November 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 52531
20 November 2001
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415725
16 October 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 60509
5 September 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 94101
30 March 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 154089
9 December 2000
Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 1513948
8 December 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 134603
15 October 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 389
13 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 158321
11 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 16936
31 October 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 164104
18 May 1999
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 798452
8 April 1999
Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129244
29 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 96948
20 April 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 26992
4 March 1997
MARPOL Annex V Examination · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1093954
28 February 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 13690
29 January 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 168156
27 July 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 70925
13 August 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 42454
20 May 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 152884
8 January 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 18606
30 October 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 134152
7 April 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 150483
22 June 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 359127
4 January 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 30026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Missing rubber matting in front of electrical panels for main engines and towing winch in fidley.
46 CFR 143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 23 June 2025
Resolution: Received objective evidence of installed rubber matting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Port main engine exhaust pipe has exhaust leak into engine room.
46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 23 June 2025
Resolution: Received objective evidence of loose bolts tightened on exhaust flange.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 June 2025
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Port 02 deck door to outside does not secure properly.
46 CFR 140.610(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 23 June 2025
Resolution: Received objective evidence of door repaired and securing properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 June 2025
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED”. Port and Starboard watertight doors to engine room were not marked.
46 CFR 144.160(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 23 June 2025
Resolution: Received objective evidence of doors with proper marking.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2025
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Vessel's installed bilge pump did not properly operate. Vessel is equipped with 02 portable pumps.
46 CFR 143.275
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2025
Resolved 15 July 2025
Resolution: operator sent photos of new pump installed and operating.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 4 June 2025
Resolved
All towing vessels must be operated in a manner that minimizes the risk of down-flooding and progressive flooding. Deck vent piping for sea chest was observed severely wasted.
46 CFR 140.610(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2025
Resolved 7 July 2025
Resolution: Received objective evidence for proper repair of vent pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 August 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Replace lagging that is oil soaked, torn and that has duct tape in the engine room to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 5 September 2024
Resolution: Received objective evidence via photographs of deficiencies rectified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Aux generator on the weather deck was not grounded properly. Properly ground generator cable in accordance with manufactures recommendation, not exposed to weather.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 5 September 2024
Resolution: Received objective evidence via photographs of deficiencies rectified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Electrical connection near aux operating station was not properly secured due to corrosion. Mount electrical connection properly to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 5 September 2024
Resolution: Received objective evidence via photographs of deficiencies rectified
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 August 2024
Resolved
New installations that are not replacements in kind must comply with the requirements of subpart C.... Generators and motors must be suitably rated for the environment where they operate, marked with their respective ratings, and suitably protected against over current. Inspectors noticed an aux generator on the aft weather deck that was not originally part of the boat outfit. Provide manufactures technical manual and electrical line diagram to the local OCMI for approval (46 CFR 143.205 (d)).
Condition: Improper/Lack of Maintenance
Due 27 September 2024
Resolved 21 October 2024
Resolution: Received tech manual and electrical wiring diagram for aux gen, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 August 2024
Resolved
Examine the condition of, and where appropriate, witness the operation of .... all overboard discharge and intake valves and watertight bulkhead pipe penetration valves. Inspectors noticed the port overboard discharge valve was leaking. Make repairs to the discharge valve in accordance with manufacture specifications.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2024
Resolved 13 September 2024
Resolution: Received objective evidence of overboard valve replaced via picture, sat.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 July 2023
Resolved
"Towing vessels must be equipped with the following equipment, as applicable to the area of operation:Illuminated magnetic compass." Compass light not operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 July 2023
Resolved 24 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2023
Resolved
"A 40–B portable fire extinguisher must be located near the storage room or cabinet." paint locker has 10-B:C extinguisher, is required to have a 40-B
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2023
Resolved 15 August 2023
Resolution: operator sent in photo of proper fire extinguisher
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 13 July 2023
Resolved
"Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature; (3) Auxiliary generator engine low lubricating oil pressure; (4) Auxiliary generator engine high cooling water temperature;" Operator was unable to test the above mentioned alarms.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2023
Resolved 15 August 2023
Resolution: operator sent in video of alarm panel in engine room and in wheelhouse to indicate test of high jacket water and low lube oil alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 July 2023
Resolved
"All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space." Aft aux gen found to be spurting oil and dripping down the deck on to the electrical panel underneath.
Operator must submit invoice as proof of purchase for the replacement gasket and within 14 days must make the deck non-penetrable by the leaking oil
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 July 2023
Resolved 15 August 2023
Resolution: Operator sent in photo of fire- stop used in gaps to prevent spill-over of oil to lower engine room. Operator also submitted photo of new gasket installed on generator.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 October 2021
Resolved
A COI may be suspended and withdrawn or revoked by the cognizant Officer in Charge, Marine Inspection at any time for noncompliance with the requirements of this subchapter. Vessel failed to complete annual inspection within required time frame. If COI renewal exam not completed before 06OCT2021, vessel will be restricted from operating until satisfactory completion. 46 CFR 136.215(c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 October 2021
Resolved 5 October 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 October 2021
Resolved
Each towing vessel must be maintained and operated to minimize fire hazards, all bilges and void spaces are kept free from oil accumulation. Vessels had excessive oil in buckets and throughout bilge spaces in engine room.
46CFR142.220
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2021
Resolved 6 December 2021
Resolution: Vessel proved compliance.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 October 2021
Resolved
Vessel must be operated in accordance with applicable laws to afford protection against hazards to life.
Carbon Monoxide detected in engine space with two separate gas meters. Gas range detected from 14-19%. Locate source of leak and provide repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2021
Resolved 6 December 2021
Resolution: Vessel proved compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2021
Resolved
There must be an installed or portable bilge pump for emergency de-watering. Vessel failed to prove function of fixed bilge system within engine room. Inspection of de-watering capabilities without overboard discharge required.
46CFR143.275
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2021
Resolved 14 December 2021
Resolution: Vessel proved compliance.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 1 October 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Crew quarters did not have emergency lighting.
46CFR143.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 November 2021
Resolved 6 December 2021
Resolution: Vessel proved compliance.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 October 2021
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced.
Found cracked pipe in elbow joint of #1 fire pump. Active spray of water was occurring at or just below deck plate level. Vessel is equipped with a capable portable pump to mitigate the hazard. Seven days to be rectified.
46 CFR 143.245(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2021
Resolved 14 December 2021
Resolution: Vessel proved compliance.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 1 October 2021
Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced.
When testing bilge suction, the valve to the engine room bilge pickup broke/not operational. With active fire main leaking innto the bilge, issuing 705 prior to towing operations. Bilge suction tests are required to be conducted at 3 month intervals.
46 CFR 143.245(a)
TABLE 46 CFR 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2021
Resolved 14 December 2021
Resolution: Vessel proved compliance.
Unknown
Issued 8 April 1999
Resolved
Recommend thaqt the oil transfer procedures be amended to satisfy the requirement for the PIC to remain at the site of the transfer.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Documentation
Issued 4 March 1997
Resolved
ABS SPECIAL SERVICE LOADLINE NOT ENDORSED FOR 1996.
Condition: Unknown
Due 5 March 1997
Resolved 17 March 1997