Records from 1985 to 2024. Most recent: inspection, 15 February 2024.
Documentation record
Registered dimensions (L × B × D)300.0 ft × 64.1 ft × 21.1 ft
Registered tonnagegross 3,656 / net 3,656
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HOUSTON, TX, UNITED STATES · built 1959
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 30 April 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3656 - Regulatory (Subpart C or D), Gross Ton
3656 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
15 February 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7866526
19 June 2006
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2696448
30 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 177028
25 July 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 167638
30 October 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946731
28 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248169
17 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 901651
10 May 1990
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216488
17 August 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202290
2 August 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206950
5 August 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343003
23 June 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204779
16 July 1987
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014645
27 October 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318339
14 July 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985115
23 June 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996710
23 June 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1302901
17 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983054
13 June 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986980
Lifesaving
Issued 2 August 1989
Resolved
REPLACE WEAK LINK TO THE INFLATABLE LIFERAFT MOUNTED ATOP THE VESSEL'S HOUSE. THE EXISTING LINK IS BENT AND WEAKENED.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Construction/Loadline
Issued 23 June 1988
Resolved
LABEL REACH RODS ON THE STARBOARD SIDE AND AFT OF ACCOMMODATION SPACE. LABEL HYDRAULIC VALVE CONTROLS AND BREAKER BOXES IN ACCOMMODATIONS.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
PROVIDE STUFFING TUBE FOR THE BULKHEAD ELECTRIC CABLE PENETRATIONS BETWEEN THE ACCOMMODATIONS AND MACHINERY ROOM ACCESS DOOR.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Construction/Loadline
Issued 23 June 1988
Resolved
RENEW ALL LIFELINE SAFETY CHAINS.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Construction/Loadline
Issued 23 June 1988
Resolved
INSTALL MISSING SECTIONS OF STORM RAIL ON TOP OF THE ACCOMMODATION HOUSE.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Construction/Loadline
Issued 23 June 1988
Resolved
ADJUST DOGS ON MACHINERY SPACE EMERGENCY ESCAPE HATCH, AND DOOR TO THE FOREPEAK/RAKE ON THE STARBOARD BOW.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Deck/Cargo
Issued 23 June 1988
Resolved
REPAIR HYDRAULIC LEAK TO THE CONTROL VALVE TO THE #3S CARGO TANK.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Construction/Loadline
Issued 23 June 1988
Resolved
VEE AND REWELD (3) BROKEN WELDS AS MARKED IN THE FOREPEAK: (1) PORT CORNER FORWARD (PREVIOUS PUNCTURE); (2) NO. 4 HEAD LOG FRAME FROM PORT; (3) NO. 10HEAD LOG FRAME.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Deck/Cargo
Issued 23 June 1988
Resolved
OPEN PRESSURE VESSEL VALVE AND MAKE IT AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Navigation
Issued 23 June 1988
Resolved
MAKE TOWING LIGHT OPERATIONAL AND PROVE PROPER OPERATION.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Deck/Cargo
Issued 23 June 1988
Resolved
REMOVE BATTERY OPERATED PORTABLE HYDRAULIC PUMP TACK WELDED TO THE DECK PORT SIDE FORWARD OF THE ACCOMMODATION HOUSE, OR SUBMIT DRAWINGS AND EQUIP-MENT DESCRIPTION TO THE [name withheld] FOR PLAN APPROVAL.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
REMOVE PAINT FROM ALL ON DECK EXPLOSION PROOF FITTINGS.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
INSTALL BLANKS IN MACHINERY SPACE CIRCUIT BREAKER PANEL. REMOVE ALL DEAD- ENDED CABLES.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
RECONNECT SEARCHLIGHT JUNCTION BOX ON TOP OF THE ACCOMMODATION (STARBOARD) AND MAKE THE CONNECTION TO THE BASE OF THE LIGHT WEATHERTIGHT.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988
Resolved
PROVIDE METAL HANGER SUPPORTS FOR ELECTRICAL CABLES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Lifesaving
Issued 23 June 1986
Resolved
PROVIDE A WHISTLE (MULTITONE) AND LIGHT FOR EACH EXPOSURE SUIT(2).
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Construction/Loadline
Issued 23 June 1986
Resolved
REPAINT VESSEL'S NAME, HOME PORT, DRAFT MARKS ON STERN.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
REPAIR/REPLACE AFT GEN. TACHOMETER.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Construction/Loadline
Issued 23 June 1986
Resolved
PROVIDE A BILGE MANIFOLD DIAGRAM OR PAINT ON EACH BILGE SUCTION LINE THE TANK TO WHICH IT SERVES.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
LABLE CIRCUITS TO LIGHTING PANEL'S CIRCUIT BREAKER IN GENERATOR ROOM. (NEAREST DOOR)
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
REPAIR OUTBOARD BUNK'S BUNK LIGHT FIXTURE-BROKEN.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
INSTALL E-LIGHTING FOR L/R STATION.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Accommodation/Occupational Safety
Issued 13 June 1985
Resolved
REPAAAAIIR OR REMOVE PORT SIDE CATWALK BROKEN AWAY FROM DECKHAND AND STANCHIONS.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985
Construction/Loadline
Issued 13 June 1985
Resolved
REPAIR HOLE IN EXHAUST CONNECTION OF FWD RAKE BILGE PUMP ENGINE.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985
Accommodation/Occupational Safety
Issued 13 June 1985
Resolved
CROP AND RENEW WASTED STEPS IN STBD LADDERWAY ALONG SIDE DECKHOUSE, (STEPS 3,4,5,,8,10 AND 12 FROM BOTTOM).
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985