AEGEAN SEA

AEGEAN SEA is a 1962 towing vessel. The Coast Guard has recorded 41 inspections since 1992, most recently in June 2025, along with 37 deficiencies, 2 operational controls and 9 casualty investigations between 2008 and 2012.

Records from 1992 to 2025. Most recent: inspection, 30 June 2025.

Built
1962
Last inspected
30 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

8644333
WDH2160
Flag
UNITED STATES
Maury page id
psix-80110

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded20
Years with a record 23 calendar years (1992–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)75.5 ft × 24.0 ft × 8.6 ft
Registered tonnagegross 146 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT CO · MADISONVILLE, LA, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Net Ton
146 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 11

Inspection history · 41

30 June 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8160154
19 August 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7969611
28 June 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7899739
19 April 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7661672
14 June 2022 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7477263
29 November 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7358516
15 April 2021 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7171183
13 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6539481
16 July 2018 Industry Initiated Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6482177
25 September 2015 Industry Initiated Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5728724
17 July 2014 Administration
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4925224
5 March 2013 Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4543872
9 August 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4405950
17 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4382377
17 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4384757
2 February 2012 Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4236692
3 September 2011 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4137560
16 December 2010 DAPI Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3917903
2 November 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3892179
15 September 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3859651
25 April 2010 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3726972
12 March 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3695906
29 January 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3685925
31 October 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3628160
1 May 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3468011
4 October 2008 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3354970
31 July 2006 MTSA Verification · Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2731110
11 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2622408
23 May 2005 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2366000
27 May 2003 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1803825
29 December 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1724948
1 May 2000 Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365748
24 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 824382
15 April 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080
19 May 1997 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098698
20 February 1997 MARPOL Annex V Examination · Deficiency Check · Uninspected Towing Vessel
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1100492
31 December 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1095232
12 November 1996 Uninspected Towing Vessel · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865737
22 April 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 112381
4 July 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 160378
13 January 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 151653

Deficiency record · 37

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 June 2025 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid. Both generators in engine room had internal windings covered in oil. Remove fire hazards from machinery as necessary to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 June 2025 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The fuel shutoff valve to the generators is stuck in the open position and will not close. Repair/replace as necessary to achieve full closure remotely to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 June 2025 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Stbd battery bank is fitted with wing nuts. Replace with devices that will prevent backing off to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 June 2025 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Gasket material in emergency escape hatches leading to main deck outside the head and engineer's cabin is wasted and does not provide a watertight seal. Hinges were also frozen in place making it difficult to open. Replace gasket material and service hinges to allow for easy escape and operation of the hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 30 June 2025 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. Watertight doors were missing signage on outside. Emergency escape hatches were missing signage both inside and outside. Mark accordingly to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 30 June 2025 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 46 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Overboard discharge valve was not secure during inspection and seized in the open position. Secure overboard discharge valve while vessel is in EPAs No Discharge Zone.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 June 2025 Resolved
A towing vessel must maintain a Towing Vessel Record (TVR). The following list of items must be recorded in the TVR or official logbook: (1) Personnel records, in accordance with (IAW) § 140.400; (2) Safety orientation, IAW § 140.410; (3) Record of drills and instruction, IAW § 140.420; (4) Examinations and tests, IAW § 140.615; (5) Operative navigational safety equipment, IAW § 140.620; (6) Navigation assessment, IAW § 140.635; (7) Navigation safety training, IAW § 140.645; (8) Oil residue discharges and disposals, IAW § 140.655;(9) Record of inspection of towing gear, in accordance with § 140.820; (10) Fire-detection and fixed fire-extinguishing, IAW § 142.240. Items (4), (5), (8), (9), and (10) were not available for inspection. Establish TVR recordkeeping onboard to the satisfaction of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2025
Resolved 18 August 2025
Resolution: Conducted deficiency check. All satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 August 2024 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, a fire main, and hoses and nozzles in accordance with paragraphs (a) through (d) of this section; or a portable pump, and hoses and nozzles, in accordance with paragraphs (e) and (f) of this section. Vessel's fixed fire pump motor was inoperable during inspection. Repair or replace as necessary.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 August 2024
Resolution: MI observed satisfactory operational test of new fire pump, hoses and nozzles.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2024 Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. Two portable fire extinguishers were found loose and without hanger or bracket that secures them into place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2024
Resolved 27 August 2024
Resolution: MI observed that the extinguishers are properly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2024 Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet for storing flammable or combustible products. Fire extinguisher designated for paint locker on deck had several cuts in the extinguisher hose that supplies agent into the locker. Replace as necessary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2024
Resolved 27 August 2024
Resolution: MI observed new hose installed on system.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 August 2024 Resolved
When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. EPIRB hydro-static release is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2024
Resolved 27 August 2024
Resolution: Operator installed new hydrostatic release unit.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 April 2021 Resolved
Survival crafts must be stowed IAW the requirements in 46CFR199.130. The vessels life raft hydrostatic release is expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2021
Resolution: Operator sent pictures of newly installed hydrostatic release.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 15 April 2021 Resolved
Vessels subject to requirements in Bridge to Bridge Act must have a valid endorsement. Vessels Bridge to Bridge certificate is expired.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2021
Resolution: Verified new Bridge to Bridge certificate on board.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 April 2021 Resolved
Emergency lighting must be provided for all internal crew working and living areas and be sufficient under emergency conditions to facilitate egress from each space. The vessel currently has no emergency lighting in crew accommodation spaces and galley space.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 April 2021
Resolution: Operator sent in pictures of bettery operated light installed in galley area and photoilluminiscent strips installed in all berthing areas.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2021 Resolved
Paints, coatings or other flammable products must be stored in a designated storage room or approved cabinet when not in use. The vessel is currently using an unapproved steel cabinet on the upper deck which does not provide an equivalent level of protection.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2021
Resolution: Routed special consideration letter for current steel flammable locker on 02 deck.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2021 Resolved
A 40-B portable fire extinguisher must be located near the flammable storage cabinet. The vessel's portable extinguisher near cabinet is smaller than 40-B.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 8 June 2021
Resolution: Received pictures from operator of newly installed extinguisher for the paint locker.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 April 2021 Resolved
Each towing vessel must be equipped with means to detect smoke in berthing spaces. The engineer stateroom did not have approved smoke detector installed. Crew installed UL approved smoke detector during inspection.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Corrected during inspection.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 April 2021 Resolved
Each towing vessel must have visual and audible alarms of high bilge levels at the operating station. The vessel currently does not have a high bilge alarm at the operating station.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 May 2021
Resolution: Tested high bilge alarm at operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 April 2021 Resolved
The fire main must have sufficient number of fire hydrants with attached hose. The engine room hydrant did not have fire hose attached. Crew attached hose during inspection.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 15 April 2021
Resolution: Corrected on the spot.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting Invalid Call Sign and Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 October 2018
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 December 2010 Resolved
Company does not have a listing of Substance Abuse Professionals (SAP)s readily available as required by 49 CFR 40.287.
Action required: 705 - Other - as specified
Due 16 January 2011
Resolved 21 December 2010
Operations/Management › Drug and Alcohol Testing › Collection Sites
Issued 16 December 2010 Resolved
Company does not have proof of training for vessel captains and supervisors that act as collectors as required by 49 CFR 40.33.
Action required: 705 - Other - as specified
Due 16 January 2011
Resolved 21 December 2010
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 16 December 2010 Resolved
Company does not have positive test results for 2006 and 2007 as required by 49 CFR 40.333.
Action required: 705 - Other - as specified
Due 16 January 2011
Resolved 16 January 2011
Documentation › Markings/Placards › Garbage Placard
Issued 31 July 2006 Resolved
Place Garbage Placard onboard as required by 33 CFR 151.59
Due 31 August 2006
Resolved 3 August 2006
Resolution: Recieved copy of receipt for required Garbage Placard. Vessel rep [name withheld] has confirmed that placard has been placed on vessel.
Documentation
Issued 20 February 1997 Resolved
PROVIDE VESSEL WITH A FCC RADIO STATION LICENCE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 20 February 1997
Navigation
Issued 20 February 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 20 February 1997
Engineering
Issued 20 February 1997 Resolved
INSTALL FIXED PUMPING, PIPING, AND STANDARD DISCHARGE CONNECTION FOR OILY WATER MIXTURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 20 February 1997
Navigation
Issued 20 February 1997 Resolved
PROVIDE THE MOST RECENT COPY OF THE INLAND NAVIGATIIONAL RULES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 20 February 1997
Navigation
Issued 20 February 1997 Resolved
PROVIDE FCC RADIO OPERATOR PERMIT.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 20 February 1997
Navigation
Issued 12 November 1996 Resolved
Provide up to date/corrected charts for area of operations
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996 Resolved
Provide evidence of servicing of life raft
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Documentation
Issued 12 November 1996 Resolved
Provide evidence of drug and alcohol prevention program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Documentation
Issued 12 November 1996 Resolved
Provide adequate oil transfer procedures
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Documentation
Issued 12 November 1996 Resolved
Provide original of Certificate of Documentation for inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996 Resolved
Apply retroreflective tape to ring buoys
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Fire Fighting
Issued 12 November 1996 Resolved
Provide proof of current hydrostatic test of fire extinguishers
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996 Resolved
[name withheld] with vessel name and stow in readily accessible location(s)
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 September 2015
Resolved 12 November 1996

Casualty record · 9

4 October 2008Routine · role: Involved in a Marine Casualty · activity 3354970
1 May 2009Routine · role: Involved in a Marine Casualty · activity 3468011
29 January 2010Routine · role: Involved in a Marine Casualty · activity 3685925
12 March 2010Routine · role: Involved in a Marine Casualty · activity 3695906
25 April 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3726972
15 September 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3859651
2 November 2010Routine · role: Involved in a Marine Casualty · activity 3892179
3 September 2011Routine · role: Involved in a Marine Casualty · activity 4137560
17 July 2012Routine · role: Involved in a Marine Casualty · activity 4384757