Records from 2016 to 2025. Most recent: inspection, 12 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
12 November 2025
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8262544
14 April 2025
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8111271
18 February 2025
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8081588
29 January 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8067659
6 February 2024
Annual Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7861610
9 April 2023
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7665874
9 April 2023
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7703889
6 February 2023
Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7632418
22 July 2022
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7544103
28 April 2022
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7440121
7 April 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7452839
9 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7348308
10 May 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7316934
10 November 2020
COI Inspection · Deficiency Check · DAPI Audit · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7092785
10 December 2019
Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6871034
24 June 2019
Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6723723
6 June 2019
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6705839
19 April 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6567860
29 January 2018
DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6634207
27 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293377
2 June 2017
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6303254
27 December 2016
Administrative Inspection · Internal Structural Exam · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6105954
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 November 2025
Resolved
Life ring light is not working. Vessel can't operate after sunset until fixed.
Action required: 705 - Other - as specified
Resolved 12 November 2025
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 November 2025
Resolved
Emergency procedures need to be posted on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 November 2025
Resolved
Paddles in life floats need to be labeled with vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to marine inspector that cause has been repaired and repairs are satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2023
Resolved
Vessel is missing the FCC Station License. Must show proof of valid FCC station License.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 10 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2023
Resolved
Emergency fuel shut off valves were not labeled. Must label emergency fuel shut off valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 9 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 February 2023
Resolved
Life float paddles were not labeled. Must label both paddles with the vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2023
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022
Resolved
Vessel lost propulsion and had to be towed in. Must conduct repairs and test the the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2022
Resolution: Replaced cylinder head, turbo and injectors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 April 2022
Resolved
Vessel failed to report loss of propulsion and grounding on APR 7th 2022. Vessel is required to be drydocked and have a damage survey conducted by CG Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: Conducted damage survey, no damage found.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 November 2021
Resolved
Aft high water alarm not working. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2021
Resolution: Installed new high water alarm and tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 November 2021
Resolved
Both paddles were broken and need replacing. Must replace both paddles and label with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 9 November 2021
Resolution: Bought 2 new paddles and labeled with vessels name.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 November 2021
Resolved
Vessel was found with only 8 flares, requirement is for 12. Must replace missing 4 flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 9 November 2021
Resolution: Bought 4 new flares. All SAT
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 November 2021
Resolved
EPIRB battery was expired. Must replace battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 18 November 2021
Resolution: New Battery installed, re tested, Test SAT
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 November 2020
Resolved
Life float was found with non repairable damage. Need to replace with new 22 person life float prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2020
Resolved 13 November 2020
Resolution: New lifefloat was purchased and labeled correctly. All SAT
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 November 2020
Resolved
COD expired in April 2020: Must renew COID prior to carrying passengers
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2020
Resolved 12 November 2020
Resolution: Applied online and paid fee's.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 November 2020
Resolved
FCC Station License was missing. Must show current or renew station license.
47 CFR 80
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2020
Resolved 13 November 2020
Resolution: Application was sent in to FCC with fees paid.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 November 2020
Resolved
FCC Radio Safety certificate expired Aug 13th 2020. Must renew Safety cert.
47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 13 November 2020
Resolution: Vessel had a FCC certified inspector come out late last night to re certify their radio and issue a new safety cert. All SAT
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 10 November 2020
Resolved
Emergency proceedures were not posted and missing. Must post emergency proceedures as required
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2020
Resolved 12 November 2020
Resolution: Found in office, brought down onboard boat and posted up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2020
Resolved
Emergency fuel shut off valves were not labeled. Must label in accordance with reg's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 12 November 2020
Resolution: Labled fuel valves, all SAT
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 November 2020
Resolved
All NAV pubs where dated 2016. Electronic Nav Chart on Garmine GPS was version 17.0, Garmine website latest verson is 20.0. All Nav pubs and electronic chart needs to be updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: All Nav pubs were downloaded to Captains phones. GPS was updated with latest software version
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 10 November 2020
Resolved
Life ring buoy light is only flashing 1 every 5-8 seconds. Light is required to flash 50-70 times per min. Either make repairs or replace light with new that meets requirements. Vessel is restricted to daylight hours only until fixed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: Bought new life ring light, tested, tested SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 November 2020
Resolved
Exhaust Clamp on Turbo is broken, must replace clamp.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: Bought 2 new clamps and installed. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2020
Resolved
Bracket on back of Main Diesel engine that supports the exhaust pipe is broken. Must make repairs or replace bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: Made new bracket and installed, all SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 November 2020
Resolved
All Watertight bulkhead penetrations need to be filled with Coast Guard approved fire retardant sealant.
46 CFR 174.114
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: Installed CG approved sealant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2020
Resolved
Exhaust cooling hose clamp is broken and pooring water into the bilge. Must make repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2020
Resolved 12 November 2020
Resolution: Bought two new clamps and installed, Tested, no leaks, all SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 November 2020
Resolved
No logs showing new hire and or quarterly crew training as required. Must start logging crew training as required
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2020
Resolved 21 January 2021
Resolution: Made new logs, all SAT
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 November 2020
Resolved
MOB drills were not being logged with all info as required and fire drills were not being logged at all. Must start logging both drills with all info as required.
46 CFR 185.520
46 CFR 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2020
Resolved 21 January 2021
Resolution: Made new logs, all SAT
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 10 November 2020
Resolved
Un able to conduct fire and MOB drills due to no deckhand onboard at time of inspection. Must conduct drills within the next 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2020
Resolved 21 January 2021
Resolution: Vessel underway and conducted drills with all employees
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2020
Resolved
Crank case breather is missing on pipe which is allowing oil to spray on engine and in bilge. Must replace missing breather.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2020
Resolved 21 January 2021
Resolution: Installed new breather
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 December 2019
Resolved
Life float needs paint, name, and capacity on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: Name and capacity has been properly displayed on both sides.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 10 December 2019
Resolved
Rudder shaft packing is leaking. Repair/Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: Rudder shaft housing was tightened, and leak has stopped.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 10 December 2019
Resolved
Provide FCC operations permit for Capt.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2019
Resolution: A valid FCC operators permit has been verified for all operators.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2019
Resolved
Bilge high level alarms are inoperable. Repair/replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Replaced float switched. Tested, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2019
Resolved
Aft bilge automatic operation is inoperable
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Replaced float switched. Tested, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 June 2019
Resolved
Renew ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Ring buoy was renewed and verified.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 June 2019
Resolved
Create log for survival gear maintenance, EPIRB testing, and drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Log containing survival gear maintenance, EPIRB testing, and drills was established and verified.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 June 2019
Resolved
Post COI and Stability letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: COI and Stability Letter has been posted in an appropriate location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019
Resolved
Some items in first aid kit are expired. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Expired items from the first aid kit have been replaced with items within its expiration date.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2019
Resolved
Life float has extensive sun damage. Replace/Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Life float has been sufficiently repaired.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 June 2019
Resolved
VHF radio must be linked to GPS, and input MMSI #.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: GPS and MMSI# have been linked to VHF radio.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 June 2019
Resolved
Provide a local section of light list and coast pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: A local section of the current Light List and Coast Pilot has been provided on board.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 June 2019
Resolved
Provide FCC operators permit for all captains.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: All operators hold the proper permits for all captains.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2019
Resolved
Provide crew for drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2019
Resolution: Upon arrival for secondary inspection, a crew was present for drills.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 December 2016
Resolved
Vessel side nav lights are broken and extinguished.
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Resolution: New lights were installed and tested all sat
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 December 2016
Resolved
Bilge high level visual alarm is extinguished.
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 3 January 2017
Resolution: New visual alarm was installed and tested all sat.
Engineering › Fuel Oil Service System › Valve
Issued 27 December 2016
Resolved
Remote fuel shut-off valves are not marked.
Action required: 705 - Other - as specified
Due 10 January 2017
Resolved 3 January 2017
Resolution: Valves are marked per CFR
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 December 2016
Resolved
Vessel is missing the emergency instructions list and the emergency broadcast placard.
Action required: 705 - Other - as specified
Due 10 January 2017
Resolved 3 January 2017
Resolution: Emergency instructions were provided and posted, emergency broadcast placard was posted.