MAURY USCG vessel records Sign in
← All vessels

BLUEWATER DIVER

BLUEWATER DIVER is a 1990 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1990, most recently in July 2026, along with 112 deficiencies — 1 with no resolution recorded —, 3 operational controls and 1 casualty investigation in 2023.

Records from 1990 to 2026. Most recent: inspection, 8 July 2026.

Built
1990
Last inspected
8 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7416
345057
Flag
UNITED STATES
367406950, 368160060, 368490240
Maury page id
psix-345057

Inspections, by type

…with no type recorded3
Years with a record 34 calendar years (1990–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.2 ft × 9.5 ft × 5.0 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOATS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 21 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3552MMSI 368490240 · active · compulsorily equipped · granted 1 August 2026, expires 1 August 2036 · licensed under a name not among this hull’s recorded names (not shown)
WDL7416MMSI 368160060 · active · compulsorily equipped · granted 27 August 2020, expires 27 August 2030
WDK9280MMSI 367406950 · active · compulsorily equipped · granted 27 June 2019, expires 27 June 2029
WDE8559MMSI 367406950 · terminated · compulsorily equipped · granted 30 April 2009, cancelled 14 June 2019
WDB3519MMSI 366888060 · expired · compulsorily equipped · granted 8 April 2003, cancelled 8 June 2013
WAK7605MMSI not assigned · cancelled · voluntarily equipped · granted 15 February 1995, cancelled 24 January 2003 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THE PHOENIX Passenger (Inspected) · MISLE 1279310 · 9 April 2023 · activity 7703889

Inspection history · 62

8 July 2026 Simplified Stability Test
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8433397
11 December 2025 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8282369
23 July 2025 Deficiency Check · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8192398
1 February 2024 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7858982
22 June 2023 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7721431
9 April 2023 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7665824
9 April 2023 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7703889
12 May 2022 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7448717
13 January 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7379725
29 July 2021 Administrative Inspection · Examination of Repairs · DAPI Audit · Deficiency Check · Annual Inspection · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7271448
26 August 2020 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7044452
20 August 2020 Internal Structural Exam · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7038227
23 January 2020 Internal Structural Exam · Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6894872
15 August 2019 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6785111
13 August 2018 Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6535062
16 January 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6592221
15 May 2017 Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6146952
3 June 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5903001
28 August 2015 Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5226066
18 June 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4899443
8 September 2011 Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4146096
11 May 2009 In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3472154
27 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3441429
3 April 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3178884
18 September 2007 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3060677
5 April 2007 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2904212
3 May 2006 Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2639400
27 September 2005 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2502438
26 July 2005 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2449981
6 April 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2326367
1 April 2004 Annual Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2035245
23 September 2003 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1907908
17 April 2003 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1770252
13 June 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1637802
9 April 2002 COI Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1600751
20 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1453944
11 June 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1065315
17 May 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1384770
17 May 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1049908
26 April 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361436
26 October 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415261
23 June 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 881833
22 April 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1455696
29 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1124077
28 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 781255
25 February 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092816
29 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084897
22 May 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086287
25 April 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1081863
26 October 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874762
17 May 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 924156
17 April 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850097
31 March 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 858942
22 March 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 856008
22 October 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 826312
28 April 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146296
11 June 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 956638
19 May 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 947586
25 October 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251323
28 May 1991 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1260784
21 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242295
14 May 1990 Initial Construction-Excluding Oversight · Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 899748

Deficiency record · 112

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2024 Resolved
Vessel failed to conduct drydock and internal structural exam. Must conduct drydock and internal structural exam prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2026
Resolution: Approved Drydock completed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2023 Resolved
Life ring floating water light was not on board vessel. Owner stated the light was not working. Make repairs or replace floating water light and test to the satisfaction of attending CG Marine Inspector. Vessel limited to day light hours only until cleared.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 27 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 April 2023 No resolution recorded
Vessel does not have a valid Certificate of Documentation (COD)on board. Vessel must show proof a valid COD prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2023 Resolved
Vessel sub-stained damage to the starboard side stern hand rail while trying to moor vessel. Passenger count reduced by 4 and no passengers allowed to sit in that area until handrail is repaired and cleared by the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2023
Resolved 22 June 2023
Resolution: Repairs completed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 May 2022 Resolved
Hydro static release for the EPIRB had expired May 2021. Must replace hrdro static release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 15 July 2022
Resolution: Installed new hydro static release with experation date of July 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 12 May 2022 Resolved
Missing logs for crew training, MOB, Fire and monthly EPIRB test. Must provide proof of all training/drills/monthly test
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2022
Resolved 15 July 2022
Resolution: Created logs with start date of inspection
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 September 2021 Resolved
Vessel did not have a high water bilge alarm installed on boat. Must have high water bilge alarm for each compartment with a through hull fitting. Install alarm and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Installed new float switch, wiring and alarm, Test SAT
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 September 2021 Resolved
Vessel only had 2 fire extinguishers on board vessel. Requirement stated on COI is 3. Missing 40-BC extinguisher must be replaced prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Bought new fire extinguisher
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 September 2021 Resolved
Vessel did not have any fire buckets on board. Must replace all 3 missing fire buckets, label properly and attach lanyards are required prior to carrying passengers.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Bought 3 new buckets, labeled properly and attached lanyards, all SAT
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 September 2021 Resolved
Both engineroom ventilation closures were siezed open and would not allow them to close in the event of engineroom fire. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Took apart both vent closures, repaired, installed and test SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 September 2021 Resolved
Emergency steering tiller was broken and would not attach to rudder. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Fab'ed new tiller for emergency steering, tested SAT
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 September 2021 Resolved
Certificate of Documentation (COD) had expire July 31st 2021. Vessel could not show proof of new valid COD. Owner must provide proof of valid COD.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: New COD applied for and arrived with new experation date of 30 Sept 2022.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 September 2021 Resolved
Life float only had 1 of the 2 required paddles. Must replace missing paddle and label with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Bought new extendable paddle and labeled both paddles with vessels name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 September 2021 Resolved
Life ring buoy retro tape was worn, faded and peeling. Must replace all retro tape with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Replaced all retro with SOLAS retro and put vessels name on ring buoy.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 September 2021 Resolved
Captain did not have a FCC operators permit. Operating a vessel with more that 6 passengers must have FCC Operators permit. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Captain provided FCC operators permit
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2021 Resolved
Starboard NAV light had broken lens. Must make repairs to light to satisfaction attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Brand new NAV light installed, tested SAT
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 September 2021 Resolved
Anchol/mast light is very dim and does not meet the 2 mile requirement. Make repairs or replace mast/anchor light.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Brand new Anchor light installed and tested SAT
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 September 2021 Resolved
Vessel does not have a paper NAV chart onboard and the GPS is not updated with latest update. Must either buy a CG approved NAV chart or update the GPS with latest update.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 2 September 2021
Resolution: Updated GPS with latest software/chart version, All SAT
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 September 2021 Resolved
Emergency fuel remote shut off valve needs labeling.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 1 September 2021
Resolution: Labeled remote fuel shut off valve
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 September 2021 Resolved
Engine guard on MDE was missing. Must have guard over rotating machinery to protect someone from injury.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Installed guard on front on engine.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 September 2021 Resolved
First aid kit had missing items. Must replace missing items to meet the requirements in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Bought new first aid kit that met the 160.041 requirements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2021 Resolved
All electrical wiring needs to be suported with metal brackets every 24 inches for CG standards or to meet ABYC standards, every 18 inches when going over machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2021
Resolved 29 September 2021
Resolution: Added suport brackets in accordance with ABYC standards. All SAT
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 August 2020 Resolved
Fore boy system not serviced and not operating as designed. Conduct annual service and repair to the satisfaction of the marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 26 August 2020
Resolution: Circut card in box was bad, rebuilt card and tested, tested SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 August 2020 Resolved
Bilge high level alarm not working. Renew/replace prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 26 August 2020
Resolution: Replaced fues and bulb, Tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 August 2020 Resolved
Renew life float prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 26 August 2020
Resolution: Replaced with new 15 person life float
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 August 2020 Resolved
Renew life float sea painter line with correct size and renew missing weak link prior to carrying passengers. Renew wasted grab line on life ring to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 27 August 2020
Resolution: Replaced new correct size sea painter and new weak link. Installed SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020 Resolved
Repair/renew life buoy float light. Operations are restricted to daylight hours only until corrected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 26 August 2020
Resolution: Replaced light with new light, tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 August 2020 Resolved
Renew wasted grab line on life ring to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 September 2020
Resolution: Replaced entire life ring with new one.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 20 August 2020 Resolved
Conduct repairs to emergency steering system and test to the satisfaction of the marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 26 August 2020
Resolution: Made repairs to tiller handle, tested SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 August 2020 Resolved
Renew/Repair missing gasket to aft hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 September 2020
Resolution: Both hatches had new gaskets installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 August 2020 Resolved
Renew missing gasket on engine room hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 September 2020
Resolution: New gasket installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2020 Resolved
Replace missing life jacket donning placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 September 2020
Resolution: New placard installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2020 Resolved
Replace missing emergency broadcast placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 September 2020
Resolution: New emergency broadcast placard installed at helm station
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2020 Resolved
Renew FCC radio station license.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 27 August 2020
Resolution: Vessel received new FCC Station License, all SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2020 Resolved
Renew operator radio permit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 1 October 2020
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 August 2020 Resolved
Locate or renew EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 27 August 2020
Resolution: Showed proof of EPRIB new registration
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 15 August 2019 Resolved
Hydro static release on EPIRB is out of date. Renew
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 August 2019
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 15 August 2019 Resolved
Repair tears and reflective material on life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2019
Resolution: Life float was repaired and painted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 August 2019 Resolved
Remark life jackets with name of vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2019
Resolution: All PFD were restenciled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 15 August 2019 Resolved
Repair approximate 12 inch full thickness crack on main deck forward of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2019
Resolution: Crack was ground back and repaired with new fiberglass and resin.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 15 August 2019 Resolved
Link VHF to GPS and Load MMSI#
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 August 2019
Resolution: VHF was renewed with GPS capable radio and MMSI number was input.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 August 2018 Resolved
Life float strobe is broken and must be replaced.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2018
Resolution: New strobe was provided and placed into service.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 August 2018 Resolved
Vessel is missingthe coast pilot and nave rules publications.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2018
Resolution: New navigation publications were provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 August 2018 Resolved
Life float maintenance is not being logged. Provide new log for maintenance.
Action required: 10 - Deficiency Rectified
Resolved 20 August 2018
Resolution: New log was provided and will be used for maintenance and EPIRB testing.
Lifesaving › Lifefloat › Painter
Issued 17 May 2017 Resolved
Life Float painter is wasted. Renew.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: New painter line was provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2017 Resolved
Anchor light is extinguished. Repair.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: New navlight was installed and tested.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 May 2017 Resolved
Reflective material on life ring is wasted. Replace.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: Reflective material was renewed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 17 May 2017 Resolved
Life Float is missing reflective material. Renew.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 5 June 2017
Resolution: New reflective material was installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 17 May 2017 Resolved
Alcohol testing swabs are expired. Provide new swabs.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: New Swabs were provided.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 May 2017 Resolved
Fuel tank fill hose is not grounded. Ground from fill neck to pipe or common ground.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: Fill pipe was properly grounded.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 17 May 2017 Resolved
Life Jacket donning placard is missing. Provide.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: NEw Placards were provided and posted.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 May 2017 Resolved
Vessel did not have any of the required navigations publications. Provide.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 5 June 2017
Resolution: New Publications were provided.
Communications › Radio Communications › EPIRB
Issued 15 May 2017 Resolved
EPIRB batterie is expired. provide new battery or new EPIRB prior to operating beyond 3 nm
Action required: 705 - Other - as specified
Resolved 19 May 2017
Resolution: Owner provided new EPIRB.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 August 2015 Resolved
Install new shaft and rudder bearings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2015
Resolved 21 September 2015
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 June 2014 Resolved
Provide new gasket for E/R hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 June 2014 Resolved
Provide retaining devices for E/R and lazzerette hatch covers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 March 2009 Resolved
Prove annual servicing for E/R fixed system. Vessel resricted from carrying passengers for hire until complete.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 31 March 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 3 May 2006 Resolved
Provide visual alarm for bilge high level alarm
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 2 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 3 May 2006 Resolved
Provide one B-I fire extinguisher prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 3 May 2006 Resolved
Provide one orange day smoke flare.
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 3 May 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 May 2006 Resolved
Provide CG Light List, U.S. Coast Pilot Pub and Tide/Tidal Current Tables.
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 2 June 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 6 April 2005 Resolved
Provide a means to dog engine compartment deck hatch and ensure hatch is watertight and has captive chain attached.
Action required: 705 - Other - as specified
Due 20 April 2005
Resolved 26 July 2005
Resolution: Vessel made proper repairs.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 1 April 2004 Resolved
Renew 6 adult PFD's. Vessel is limited to not more than 11 persons until completed.
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 8 April 2004
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 April 2004 Resolved
Properly mount B-II fire extinguisher for the engine compartment.
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 8 April 2004
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 April 2004 Resolved
Properly mount junction box for battery charger in the engine compartment.
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 8 April 2004
Resolution: Corrected.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 April 2004 Resolved
Post Emergency Radio Broadcast Placard.
Action required: 705 - Other - as specified
Due 8 April 2004
Resolved 8 April 2004
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 17 April 2003 Resolved
Renew battery in EPIRB. Vessel is limited to not more than 3 miles from shore until completed.
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 30 April 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 17 April 2003 Resolved
Renew 6 adult PFD's & 1 child size PFD. Vessel is limited to not more than 11 persons (1 child) until completed.
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 30 April 2003
Resolution: Corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 April 2003 Resolved
Repair waterlight for ringbuoy.
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 30 April 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 9 April 2002 Resolved
Provide 4 additional adult PFD's. Vessel is limited to not more than 13 total persons until completed. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 13 June 2002
Resolution: Corrected.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Renew gaskets on forward & aft deck hatches. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 13 June 2002
Resolution: Corrected.
Construction/Loadline › Structures
Issued 9 April 2002 Resolved
Install captive chains on forward & aft deck hatches. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 16 April 2002
Resolved 13 June 2002
Resolution: Corrected.
Lifesaving
Issued 17 May 2001 Resolved
Repair the L/F, replace the worn lines and affix new retro-reflective tape as needed.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Electrical
Issued 17 May 2001 Resolved
Provide battery boxes for the batteries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Navigation
Issued 17 May 2001 Resolved
Repair the anchor light._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Lifesaving
Issued 17 May 2001 Resolved
Provide a watertight container for the flares._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Engineering
Issued 17 May 2001 Resolved
Provide chaffing protection where needed on the M/E fuel line._x001C_ _x001C_ This item to be corrected prior to carrying passengers for hire._x001C_ _x001C_
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Lifesaving
Issued 17 May 2001 Resolved
Provide 1 additional adult and child PFD._x001C_ _x001C_ Passengers reduced to 14 adults and 1 child until this item is corrected._x001C_ _x001C_
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Lifesaving
Issued 26 April 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Deck/Cargo
Issued 26 April 2000 Resolved
Repair/replace the anchor._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Engineering
Issued 26 April 2000 Resolved
Properly support the fuel line to the main engine._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Documentation
Issued 22 April 1999 Resolved
Provide latest MIS report and provide written procedures on policy for randomly selecting names for drug tests._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 May 1999
Resolved 26 April 1999
Fire Fighting
Issued 22 April 1999 Resolved
Install a fixed fire extinguishing system in the engine room as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Lifesaving
Issued 22 April 1999 Resolved
Properly rig line to life ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Lifesaving
Issued 22 April 1999 Resolved
Repair the life float as needed._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1999
Resolved 22 April 1999
Fire Fighting
Issued 25 April 1996 Resolved
Replace discharge hose on hand fire pump with a longer one._x001C_ (8 foot minimum)
Condition: Unknown
Due 15 May 1996
Resolved 3 June 1996
Navigation
Issued 25 April 1996 Resolved
Repack or tighten rudder stuffing box.
Condition: Unknown
Due 15 May 1996
Resolved 3 May 1996
Navigation
Issued 25 April 1996 Resolved
Replace emergency tiller._x001C_ (deteriorated)
Condition: Unknown
Due 15 May 1996
Resolved 3 June 1996
Lifesaving
Issued 25 April 1996 Resolved
Replace retro-reflective material on one adult lifejacket. Total capacity of the vessel is reduced to 16 persons until this is accomplished.
Condition: Unknown
Due 15 May 1996
Resolved 3 June 1996
Navigation
Issued 17 April 1995 Resolved
Vessel restricted to daylight operations only until anchor light is repaired.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Reroute painter for lifefloat per discussion with inspector. _x001C_ Painter as presently rigged "may" have difficulty deploying.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Vessel restricted to 9 adult passengers and no children until 8 adult and two childrens approved life preservers are placed on board._x001C_ (Retro reflective tape on jackets failed)
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Accommodation/Occupational Safety
Issued 17 April 1995 Resolved
Darken or replace plastics placard.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995 Resolved
Remount engine alarm bell to prevent it from shorting out on terminal bar._x001C_(bell temporarily mounted)
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Stencil capacity, in number of persons allowed, on lifefloat.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Lifesaving
Issued 17 April 1995 Resolved
Stencil vessel name on paddles for lifefloat in 1" letters.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Navigation
Issued 22 March 1994 Resolved
Repair or replace emergency tiller.
Condition: Unknown
Due 29 March 1994
Resolved 4 April 1994
Fire Fighting
Issued 22 March 1994 Resolved
Service all fire extinguishers.
Condition: Unknown
Due 29 March 1994
Resolved 4 April 1994
Lifesaving
Issued 22 March 1994 Resolved
Mount lifefloat in appropriate bracket to allow easy float free operation.
Condition: Unknown
Due 12 April 1994
Resolved 4 April 1994
Documentation
Issued 22 March 1994 Resolved
Repaint name on stern of vessel.
Condition: Unknown
Due 22 April 1994
Resolved 4 April 1994
Fire Fighting
Issued 22 March 1994 Resolved
Repair or replace as necessary hand fire/bilge pump due to difficulty in priming.
Condition: Unknown
Due 29 March 1994
Resolved 4 April 1994
Lifesaving
Issued 22 March 1994 Resolved
Repair inoperative waterlight on ring lifebuoy. You are restricted to daylight operations until it is repaired and in no case shall it go unrepaired after 29MAR94.
Condition: Unknown
Due 29 March 1994
Resolved 4 April 1994
Documentation
Issued 19 May 1992 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Electrical
Issued 19 May 1992 Resolved
PROVIDE 2 OPERABLE FLASHLIGHTS
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Documentation
Issued 19 May 1992 Resolved
PROVIDE DRUG TESTING RECORDS
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Documentation
Issued 28 May 1991 Resolved
STABILITY LETTER NOT POSTED.
Condition: Unknown
Due 25 June 1991
Resolved 13 February 1992
Construction/Loadline
Issued 28 May 1991 Resolved
PLUG UP UNUSED HULL PENETRATION FOR BILGE PUMP IN LAZARETTE.
Condition: Unknown
Due 25 June 1991
Resolved 13 February 1992
Construction/Loadline
Issued 28 May 1991 Resolved
REPLACE MISSING LANYARD FOR HATCH COVER ON FORWARD BOMAR HATCH.
Condition: Unknown
Due 25 June 1991
Resolved 13 February 1992
Lifesaving
Issued 28 May 1991 Resolved
PROVIDE QUICK RELEASE FOR LIFEFLOAT.
Condition: Unknown
Due 25 June 1991
Resolved 13 February 1992
Navigation
Issued 14 May 1990 Resolved
PROVIDE THE FOLLOWING PUBS: 46CFR SUBCHAPTER "T", 47CFR PART 80 FCC RADIO, NAVIGATION RULES OF THE ROAD, AND NAVIGATION CHARTS FOR THE OPERATING AREA.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Documentation
Issued 14 May 1990 Resolved
PROVIDE A VALID FCC RADIO SAFETY CERTIFICATE, RADIO STATION LICENSE AND MARINE RADIO OPERATORS LICENSE.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Unknown
Issued 14 May 1990 Resolved
UPON ARRIVAL NOTIFY THE OFFICER IN CHARGE OF MARINE INSPECTION, MIAMI, FL PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990

Casualty record · 1

9 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7703889
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.