Records from 2016 to 2024. Most recent: inspection, 13 December 2024.
Inspection history · 33
13 December 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8046995
25 October 2024
ISPS Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8024544
29 May 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7905914
25 March 2024
Administrative Inspection · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7882288
8 February 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7859094
3 October 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7802660
22 August 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7774244
8 August 2023
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7762594
17 July 2023
Administrative Inspection · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7740482
16 January 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7621861
18 November 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7596700
24 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7542190
21 August 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7539283
11 July 2022
PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7503214
12 January 2022
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7377614
10 August 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7282937
9 July 2021
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7250197
4 January 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7119156
23 December 2020
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7115347
11 November 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7093623
15 June 2020
PSC A · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6977006
25 February 2020
PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6915130
14 February 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6909191
3 October 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6825707
9 April 2019
Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6660304
9 October 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6557728
9 April 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387720
3 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6280064
6 March 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6099851
31 January 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6080355
31 August 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5987501
28 May 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5888974
22 February 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5819794
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 March 2024
Resolved
..That the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCOs observed #2 fire pump actively leaking from packing gland while pump is not running
(74) SOLAS I/11.a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2024
Resolution: RCVD proper documentation from Flag
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 March 2024
Resolved
...All electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist.
PSCOs observed exposed wiring in machinery spaces.
(74) SOLAS II-1/27(a)(i)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 3 April 2024
Resolution: RCVD proper documentation from flag
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 March 2024
Resolved
The ring lines and letters shall be painted white or yellow on a dark background.
PSCOs observed port side load lines unpainted.
ICLL (66) Annex I/8
Action required: 10 - Deficiency Rectified
Resolved 3 April 2024
Resolution: RCVD proper documentation from flag
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 8 February 2024
Resolved
A fireman's outfit shall consist of personal equipment comprising of protective clothing of material to protect the skin from the heat radiating from the fire...PSCO's observed during the fire drill, both dressed out firefighters did not have a flashood and had exposed skin.
74SOLAS CH.II-2/Reg 19(a)(i)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 8 February 2024
Resolution: Master was able to produce flashoods, they were stored in a separate location from the firefighter's outfit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2024
Resolved
...and in cargo ships at least one-half of the total number of lifeguoys shall be provided with efficient self-igniting lights. PSCO's observed STBD side lifebuoy light did not turn on or ignite when shaken.
74SOLAS CH. III/Reg. 21(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 February 2024
Resolution: Master was able to replace the non-operational light with a working light.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 8 August 2023
Resolved
The International Load Line Certificate (1996)shall not be delivered to the ship until the officer or surveyor acting under the provisions of article 13 of the present convention has certified that the marks are correctly and permanently indicated on the ship's sides. Vessel's load line markings do not reflect the load line marks as indicated on the ship's certificate.
ICLL 66 Annex I Reg. 9
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 23 August 2023
Resolution: SEC Miami PSC/Arrivals was provided an updated ILCC and photos verifying that the vessel's load line markings are in compliance with the ILCC.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 August 2023
Resolved
The conditin of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. The main and emergency fire pump was able to supply adequate/sufficient pressure but the packing gland leaked in both pumps when set at a lower operational pressure.
74SOLAS(20)I/11(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2023
Resolved 22 August 2023
Resolution: Received report and video of fire pumps operating adequately. Deficiency rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 17 July 2023
Resolved
The company should establish procedures to ensure that the ship ismaintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The ship's company fialed to fully implement the requirements of the ISM Code by not providing necessary safety measures as stated to be required in the SOLAS Conditional Cargo Ship Safety Equipment Certificate Remarks. No rescue boat was onboard as required and marked to be present on the Form E when PSCOs came onboard.
74 SOLAS (2020 Cons.) IX/3.1 ISM Code 10.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 28 July 2023
Resolution: IBS Letter states, "The Company developed additional safety measures stated through a Company's letter to keep & implement on board in the meantime the Rescue Boat us under repair."
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 July 2023
Resolved
All the life-saving appliances shall be kept in working order and available for immediate use before the ship leaves port and at all times during the voyage. The vessel’s rescue boat was not onboard or available for immediate use.
74 SOLAS (81 Amend.) III/4(c)
Action required: 30 - Ship detained
Resolved 28 July 2023
Resolution: IBS Class report states, "Rescue Boat repair ashore was completed by recognized shop and it is available on board and tested to surveyor satisfaction. Conditional SE certificate was removed, and existing SE Full term certificate remain valid."
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. To ensure that the ship...will remain fit to proceed to sea without danger to the ship or persons on board. The emergency fuel shutoff for emergency generator was inoperable. 74SOLASCh.1/Reg.11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 10 August 2021
Resolution: Received class document accepting the repairs made to the fuel shutoff valve.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 July 2021
Resolved
The fire resistance of doors shall as far as practicable be equivalent of that of the division in which they are fitted. Class B-15 fire door to AC room would not close.
74SOLAS Ch. II-2/Reg. 47(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2021
Resolved 6 October 2021
Resolution: Received class attestation for repair and door installation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2020
Resolved
In a ship in which fuel is used, the arrangements for the storage, distribution, and utilization, of the oil fuel. Shall be such as to ensure safety of the ship... PSCO found fuel fittings over the #2 SSDG temporarily patched and actively leaking.
74SOLAS II-2/33(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2020
Resolution: PSCOs received Flag documentation attesting patch repaired, PSCOs visited vessel and verified fuel fitting fixed and without any leaks.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 23 December 2020
Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall be of a design approved by the administration... PSCOs observed installation of an additional testing valve in OWS system that is not approved by flag.
MARPOL (11CONS) ANNEX I/14.6
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2020
Resolution: PSCOs received Flag documentation attesting removal of additional testing valve, PSCOs visited vessel and verified the additional testing valve was remove.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 December 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board. PSCOs observed both fire pumps actively leaking from packing glands while pumps were not running.
74SOLAS I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2020
Resolution: PSCOs received Flag documentation attesting fire pumps were fixed and no longer leak, PSCOs visited vessel, ran fire pumps and verified that fire pumps no longer leaks.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 11 November 2020
Resolved
In cargo ships less than 5,000 GT there shall be a self-contained emergency source of power located to the satisfaction of the Administration capable of supplying the illumination at the launching stations and stowage positions of survival craft prescribed in sub-paragraphs (a)(ii), b(ii) and b(iii) of regulation 19 of Chapter III, and in addition such other services as the Administration may require, due regard being paid to regulation 38 of chapter III. Sector Miami received notification that the emergency generator is currently out of order and undergoing repairs. 74 SOLAS II-I/26.b(i)17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2020
Resolution: On 02DEC2020, PSCOs received Flag state report attesting to completed repairs to the E-Generator. on 04DEC2020 PCSOs attended the vessel and witnessed satisfactory test of E-generator. 01 Def. Cleared, 00 defs outstanding.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 19 June 2020
Resolved
The company should establish procedures plans and instructions.. For key shipboard operations concerning the safety of the ship.. The various tasks should be defined and assigned to qualified personnel. Chief Engineer could not demonstrate simulated activation of CO2 system for engine room. 74SOLAS(14CONS)IX/3.1 ISM Code REG 7.
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Chief Mate demonstrated to the Chief Engineer how to activate the CO2 System by showing him step by step procedures. Chief Engineer at the end of the exam was then able to satisfactorily demonstrate activating the device.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 19 June 2020
Resolved
There shall be permanently exhibited in all new and existing ships for the guidance of the ships officers general arrangement plans showing clearly for each deck... The various fire sections enclosed by "A" class divisions. Various doors identified by fire control plans as self-closing were tied open. Door leading into laundry space is warped and unable to self close. 74SOLASII-1/REG 4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2020
Resolved 29 July 2020
Resolution: Recieved class report attesting to the operation of class "A" fire door
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
Objective evidence discovered during an expanded ism exam revealed the following non-conformities: the vessel failed to fully implement the requirements of the ISM code through their SMS procedures as evident by the following deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit.
74 SOLAS (2014) IX/3.1
ISM CODE PART A
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: All ISM deficiencies were cleared. An external ISM audit was completed and attached in documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
The company should ensure that each ship is manned with qualified, certified, and medically fit seafarers in accordance with national and international requirements. The vessel has 03 crewmembers with expired medical certificates.
ISM Code Part A 6.2.1
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: All current crew medical certificates confirmed to be valid and on file aboard
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
The company should establish programs for drills and exercises to prepare for emergency actions. The Vessel’s SMS outlines the frequency the vessel should be conducting drills in form 305. The vessel is not following the drill schedule and is overdue on their enclosed space entry and rescue drill and their security drill. Last drills conducted on 21SEP19 for both.
ISM Code Part A 8.2
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: Enclosed space entry and rescue drill and security drill have been completed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company, investigated and analyzed with the objective of improving safety and pollution prevention. The vessel’s SMS requires the crew to record non conformities on form 401 and to track all non conformities on form 403. The Vessel is not properly tracking the 401s on the 403 and is not closing out all recorded non-conformities. The vessel currently has 09 non-conformities that haven’t been closed out on the form 403.
ISM Code Part A 9.1
*30bc*
*Deficiency was originally issued as a code 30 but downgraded to a code 17*
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The tracking and closing-out of NCR’s has been updated and logged on form 403.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
In meeting these requirements, the company should ensure that: records of these activities are maintained. The vessel completed a non-conformity report for the emergency generator but did not document the of the correction nor measures to prevent recurrence.
ISM Code Part A 10.2.4
*30bc*
*Deficiency was originally issued as a code 30 but downgraded to a code 17*
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The NCR for the repairs to the E-gen have been updated with corrections and corrective preventative measure information.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 28 February 2020
Resolved
In meeting these requirements, the company should ensure that… any non-conformity is reported, with its possible cause. Vessel’s SMS includes weekly and monthly checklists of the rescue boat and equipment. The 2nd Officer completed a weekly inspection of the boat on 22FEB2020 and did not note any non-conformities. When asked by PSCO’s about the rescue boat, the crew attempted to start the boat but engine did not start. The 2nd Officer admitted to the PSCO this was a problem and never notated this on the check sheet mentioned above nor reported the non-conformity.
ISM Code Part A 10.2.2
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: The rescue boat was reported properly as a non-conformity and was sent ashore for repairs. It was returned and satisfactorily tested for operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 28 February 2020
Resolved
After any survey of the ship under regulations 7, 8, 9, and 10 of this chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of administration. The Cargo Ship Safety [name withheld] states the vessel must have a rescue boat on board. The rescue boat’s engine found was found to be inoperable and a non-conformity report was not submitted to company until after PSCO requested to test the boat. See deficiency number 1.6.
SOLAS 74 1/11
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: The rescue boat motor was repaired and a new Cargo Ship Safety Equipment Certificate was issued with the correct survey date.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 February 2020
Resolved
After any survey of the ship under regulations 7, 8, 9, and 10 of this chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of administration. PSCO observed a fracture in the #9 ballast tank bulkhead causing ballast water to leak into the cargo hold.
SOLAS 74 I/11
*30bc*
*Deficiency was originally issued as a code 30 but downgraded to a code 17.*
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The area of damage to the # 9P Ballast Tank Longitudinal Bulkhead, iwo of the lighting recess, was cropped out and inserted with new steel. A satisfactory pressure test of the repairs was conducted on 06MAY2020.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 February 2020
Resolved
The construction and means for securing the weather tightness of cargo and other hatchways in positions 1 and 2 shall be at least equivalent to the requirements of regulation 16, unless the application of regulation 15 to such hatchways is granted by the administration. The seals on the three escape hatches from the cargo hold to the open deck are not watertight. PSCO’s had the crew close the hatches and observed areas of sunlight.
ICLL (88 Proto) 14(1)
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: The gasket seals on the three (3) noted hatchway accesses to the cargo were changed. A hose test was carried out by the crew and witnessed by the surveyor.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 February 2020
Resolved
There shall be permanently exhibited in all new and existing ships for the guidance of the ship’s officers’ general arrangement plans showing clearly for each deck… the various fire sections enclosed by “A” Class divisions. The A-60 door leading to the galley was held open by a hold back hook, breaking the A class boundary and not following the fire control plan.
SOLAS 74 II-2/4
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The hold-back hook on the A-60 door to the galley was removed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 28 February 2020
Resolved
The inspection and survey of ships… shall be carried out by officers of the administration. The interim Cargo Ship Safety Equipment Certificate is missing information for the survey date on which the certificate is based.
74 SOLAS (14) I/6(a)
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The ‘Interim’ SOLAS Cargo Ship Safety Equipment Certificate was updated with the “Completion
date of the Survey on which this Certificate is based” date.
01 - Certificates & Documentation › 011 - Ships Certificates › Continuous synopsis record
Issued 28 February 2020
Resolved
The Continuous Synopsis Record shall be kept on board the ship and shall be available for inspection at all times. CSR #8 is a copy and the original is kept in the Bahamas.
74 SOLAS (14) XI-1/5.10
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The ‘Original’ CSR # 8 has been delivered to the vessel and is on file aboard.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 28 February 2020
Resolved
The bunker delivery note shall be kept on board the ship in such a place as to be readily available for inspection at all reasonable times. It shall be retained for a period of three years after the fuel oil has been delivered on board. Vessel could not provide bunker delivery notes for fuel delivered on 05DEC2019 and 08NOV2019.
MARPOL VI/18.6
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The missing bunker delivery notes for 08 November 2019 & 05 December 2019 have been provided
aboard the vessel and are on file.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 28 February 2020
Resolved
The Oil Record Book Part I shall be completed on each occasion… whenever any of the following machinery space operations takes place in the ship… collection and disposal of oil residues (sludge). Vessel did not note in the Oil Record Book Part 1 the offload of 122 GLNS of dirty oil and 306 GLNS of sludge during dry dock in Colombia as noted on the receipt.
MARPOL I/17.2.3
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: The Oil Record Book was updated to include the off-loading transfer receipts for dirty oil and oily
sludge which occurred when the vessel was on dry dock at ASTIVIK Shipyards in Cartagena,
Colombia.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 28 February 2020
Resolved
Every Seafarer holding a certificate issued under the provisions of the Convention, who is serving at sea, shall also hold a valid medical certificate. The 2nd Engineer, BOSUN, and 2nd Officer’s medical certificates are expired.
STCW I/9.3
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: All current crew medical certificates confirmed to be valid and on file aboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 February 2020
Resolved
The master, owner, operator, agent, or person in charge of a vessel subject to this subpart and this section must submit a ballast water report to the National Ballast Information Clearinghouse (NBIC) by electronic ballast water report format using methods specified at NBIC's Web site at http://invasions.si.edu/nbic/submit.html... Submit the ballast water report no later than 6 hours after arrival at the port or place of destination, or prior to departure from that port or place of destination, whichever is earlier. Vessel did not submit their ballast water report upon arrival to the Miami River within the required timeframe.
33 CFR 151.2060(b)
17bc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2020
Resolved 15 June 2020
Resolution: Vessel submitted a copy of their ballast water report to the NBIC for arrival on 13JUN2020. The report has been uploaded into documents and deficiency cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 25 February 2020
Resolved
The company should ensure that valid documents are available at all relevant locations. The vessel does not have a valid Cargo Ship Safety Equipment Certificate onboard or the original copy of the Continuous Synopsis Record #8.
ISM Code Part A 11.2.1
30bc
Action required: 30 - Ship detained
Resolved 3 June 2020
Resolution: The Original CSR # 8 has been delivered to the vessel and is on file aboard.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 25 February 2020
Resolved
Crew members with enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held on board the ship at least once every two months. The Vessel is overdue in completing their enclosed space entry and rescue drills. The last enclosed space entry drill was completed on 21SEP2019.
74 SOLAS(14) III/19.3.3
17bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2020
Resolution: Enclosed space entry and rescue drill has been completed.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 3 October 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...to proceed to sea without danger to the ship or persons onboard. Starboard side pilot ladder had cracks in the bottom step. 74 SOLAS (14) CH I/Reg. 11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 25 October 2019
Resolution: The vessel removed the damaged step.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 October 2019
Resolved
Each contracting government undertakes to make available...appropriate shore-based facilities for space and terrestrial radio communications services having due regard to the recommendations of the organization in accordance with resolution A.801(19)...12.2 this battery should be equipped with a non replaceable seal to indicate that it has not been used. One battery for the GMDSS radios did not have a seal indicating that it has not been used. 74 SOLAS (14) CH IV/Reg. 5.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 25 October 2019
Resolution: Th vessel replaced the used battery with a new one.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 3 October 2019
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded in the Oil Record Book...each completed operation...and each completed page shall be signed by the master of the ship. Master has not signed the Oil Record Book since the last week of July. (MARPOL 2017, Annex I, Reg. 17.4)
Action required: 10 - Deficiency Rectified
Resolved 3 October 2019
Resolution: PSCOs observed the Master signed the pages were his signature was missing.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 3 October 2019
Resolved
The bunker delivery note shall be kept onboard the ship...and shall be retain for a period of 3 years. The Chief Engineer could not provide bunker delivery notes for 09/10/19, 08/28/19, 08/14/19, and 07/31/19. (MARPOL 2017, Annex VI, Reg. 18.6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 26 October 2019
Resolution: VESSEL PROVIDED DELIVERY NOTES FOR THE MISSING DATES. SULVER CONTENT VERIFIED AS LESS THAN .001%
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019
Resolved
If your vessel is grather than or equal to 300 GT...you must submit a signed, certified, and complete NOI. Vessel has not submit a NOI, no VGP onboard. (2013 VGP 1.5.1.1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2019
Resolved 25 October 2019
Resolution: The vessel submitted a NOI and was confirmed through the EPA's database.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 April 2019
Resolved
Each operation described in Reg 17.2 shall be fully recorded so that all entries in the book appropriate to that operation are completed. C/E failed to use correct units of measurements and the correct item numbers for discharge to reception facilities and position of discharge. - MARPOL I/17.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 April 2019
Resolution: Flag Attestation received. Oil Record Book Entries corrected in proper format. PSCO reviewed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 April 2019
Resolved
Fire doors in main vertical zones, bulkheads and stairway enclosures...shall be of the self-closing type. Hold-back hooks not subject to control station release, will not be permitted. 03 doors in the ladder well leading to the bridge were found held open by hold-back hooks. In addition, doors leading to the escape hatch were found and workshop in E/R were found with hold-back hooks. - 74 SOLAS (Unamended) Reg 37 (f)
Action required: 10 - Deficiency Rectified
Resolved 9 April 2019
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 9 April 2019
Resolved
The operator of a vessel with a capacity of 250 barrels of oil or more shall provide trasnfer procedures that meet the requirements of this part and part 156. Vessel does not maintain oil transfer procedures. - 33 CFR 155.720
Action required: 703 - Prior to bunkering operations
Due 11 April 2019
Resolved 10 April 2019
Resolution: Vessel master forwarded a copy of the newly established vessel transfer oil procedures.
Fire Fighting › Fire Main › Condition
Issued 24 February 2016
Resolved
0725 - Fixed Fire Extinguishing Installation - In all new and existing ships, fire-extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. Fire main between cargo holds one and two on starboard side is leaking as a result of corrossion. 74SOLAS Ch.II-2/Reg.15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2016
Resolved 25 February 2016
Resolution: Cook Islands Flag Surveyor report was sent in on 25FEB16 pertaining to the deficiency being rectified. Repairs to the fire main were completed. It has been inspected, tested, and found to be in satisfactory condition at this time.