Records from 1994 to 2022. Most recent: operational control imposed, 30 September 2022.
Inspection history · 25
29 September 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7563740
10 August 2021
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7285041
10 August 2021
Damage Survey
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7285578
29 July 2021
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7276303
29 October 2020
Annual Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7086718
14 November 2019
Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6855905
22 August 2018
Initial Certification
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6521430
13 June 2018
MTSA Verification · Administration · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6443978
23 February 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5082745
8 January 2015
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5077000
7 October 2014
Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5005439
29 March 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3974783
27 March 2011
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3974862
27 January 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3934513
17 May 2010
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3755764
12 January 2009
Administration
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 3392857
22 February 2005
MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2297024
8 October 2004
Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 2519222
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1968370
1 April 2002
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1601264
14 June 2000
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 278956
19 April 1999
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 427841
23 October 1997
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 409324
18 September 1997
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 409620
2 January 1994
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 4222
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 September 2022
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. The starboard main engine has a significant leak at high-pressure fuel oil line where the line connects to the high-pressure fuel oil pump. Repair the fuel leak to the satisfaction of an attending marine inspector.
Action required: 30 - Ship detained
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 September 2022
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from the accumulation of combustible and flammable materials and liquids insofar as practical. The port main engine fuel oil return line is leaking, located at the forward machinery space bulkhead lower most 90 degree fitting. Repair the fuel leak to the satisfaction of an attending marine inspector.
Action required: 30 - Ship detained
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 September 2022
Resolved
Each towing vessel must be fitted with a general alarm that is capable of notifying persons in any accommodation, workspace, and the engine room. The vessels general alarm was not functioning at any of the required spaces. Repair to the satisfaction of an attending marine inspector.
Action required: 30 - Ship detained
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 29 September 2022
Resolved
Alarms must: be visible and audible at each operating station. The vessel did not have visual or audible alarms for high cooling water or low lubricating oil pressure for main propulsion and auxiliary engines nor a machinery summary alarm at the operating station. Repair to the satisfaction of an attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 29 September 2022
Resolved
Alarms must: be visible and audible at each operating station. The vessels high bilge level alarm did not have any visual indicator at the operating station. Repair to the satisfaction of an attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 29 September 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Low hydraulic steering fluid levels. The vessel was unable to determine if the vessel is equipped with or test the low steering fluid level alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 September 2022
Resolved
The master of a towing vessel must ensure drills are conducted to ensure that all crewmembers are capable of performing the duties during emergencies. No drills documented.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 29 September 2022
Resolved
Any vessel of at least five net tons which engages in coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. COD Expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 29 September 2022
Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. No evidence or enrollment in drug and alcohol program.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2022
Resolved
Each towing vessel must be equipped with navigational lights, shapes, and sound signals. The vessels sound signaling horn was not functioning. Repair to the satisfaction of an attending marine inspector in accordance with 33 CFR 86.01(h).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 September 2022
Resolved
47 CFR 80.415 and 47 CFR 80.13(c), stations must have an authorization granted by the Federal Communications Commission. Station license expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 September 2022
Resolved
Each towing vessel must be equipped with navigational lights, shapes, and sound signals. The vessels masthead light was not functioning. Repair to the satisfaction of an attending marine inspector in accordance with 33 CFR part 84.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 September 2022
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures.
(b) The owner, managing operator, or master must ensure that all persons on board a towing vessel comply with the health and safety plan.
See 46CFR140.505, 510 and 515 for details. Vessel does not have Health and Safety Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 September 2022
Resolved
Each lifebuoy with a floating electric water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the buoy with a corrosion-resistant clip to allow the water light to be quickly disconnected from the lifebuoy. The clip must have a strength of at least 22.7 kilograms (50 pounds). Watter light not attached properly.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 29 September 2022
Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. No waste management plan to comply with 33CFR151(b) posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 January 2023
Resolution: Inspected, tested, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 August 2021
Resolved
Propulsion machinery, including main engines and reduction gears must Be maintained to ensure proper operation.
Report of Port reduction gear shaft failure. Vessel is to conduct repairs and operational tests to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2021
Resolved 27 August 2021
Resolution: Got the vessel underway to test propulsion. All sat.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 July 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Found vessel's bilges to have an excessive amount of oil in the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 27 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 July 2021
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet when not in use. Found a filled gasoline can not stored in a flamable liquids container.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 27 August 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 July 2021
Resolved
If an approved flammable liquids container is used it
must be properly secured and a 40-B portable fire
extinguisher must be located in the vicinity of the
cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 27 August 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 July 2021
Resolved
Found the emergency lighting battery unsecured.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 August 2021
Resolved 27 August 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2020
Resolved
Bow deck has holes rusted through in vicinity of man hole. Crop and renew decking iaw nvic 7-68.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 21 January 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2020
Resolved
Deck in storage closet in galley is holed going into engine room. Crop and renew decking iwo old toilet piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 21 January 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 October 2020
Resolved
Lights in galley area are missing globes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 21 January 2021
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 29 October 2020
Resolved
The nozzle for the emergency fire pump hose was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 29 October 2020
Resolved
Extra PFD's were stowed in carboard boxes in galley. Provide suitable storage boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2020
Resolved
Life jackets were not properly labeled with vessel name. Vessel name must be in block letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2020
Resolved
The lanyard holding floating lights is too short. Line must be between 3-6 foot in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2020
Resolved
The light cover on fire alram is broken due to engine room door hitting it while open. Replace cover and ensurte light operates as designed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 October 2020
Resolved
The pop off valves on the pressure tanks did not reseat properly. Test or replace pop off valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2020
Resolved
The 160 B semi portable fire extinguisher wasn's properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 October 2020
Resolved
There wsa a 40 B portable fire extinguisher sitting on the deck in galley area. Properly mount fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 October 2020
Resolved
First aid kit on board had expried items inside. Replace first aid kist with unexpired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2020
Resolved 21 January 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2020
Resolved
There was paint stored in cabinet in galley. Provide a proper flammable storage locker for flammable materials.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 21 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 October 2020
Resolved
Provide a marked location to store workvest that is seperate from the type 1 pfd's.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 21 January 2021
Navigation
Issued 18 September 1997
Resolved
FOG BELL MISSING.
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997
Accommodation/Occupational Safety
Issued 18 September 1997
Resolved
MARPOL POLLUTION PLACARD MISSING
Condition: Unknown
Due 4 November 1997
Resolved 4 November 1997