MAURY USCG vessel records
← All vessels

M/V ZOIE

Built
1974
Last inspected
30 April 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 30 April 2025
…with no type recorded10
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 14 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP3081
129631
Flag
UNITED STATES
Maury page id
psix-129631

Documentation record

Registered dimensions (L × B × D)49.1 ft × 20.1 ft × 5.6 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSABINE RIVER FUEL CO INC · ORANGE, TX, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUMA, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 15 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 31 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 8 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 30

30 April 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8124195
24 March 2025 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8140124
21 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7917087
15 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7879676
3 July 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7780123
29 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7725419
25 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7515920
19 July 2022 Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7510998
5 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7505053
15 February 2022 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7396935
1 November 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7344157
31 October 2021 Type not recorded
No type recorded · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 7351929
14 June 2021 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7225682
26 May 2021 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7207515
20 April 2021 Initial Certification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7170702
9 January 2020 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6886332
2 January 2020 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6886756
29 March 2019 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6752325
27 March 2019 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6650317
27 March 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6655397
9 February 2018 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6352847
6 November 2017 Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6293447
10 November 2015 Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5751264
1 September 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4181683
2 June 2010 Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3756541
28 February 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3155128
28 February 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3155151
30 September 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 659098
13 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102823
13 September 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 171433

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2024 Resolved
Suspected damage or deterioration to the hull plating that may affect the seaworthiness of the vessel. An internal structural examination of the forward void space will be required due to excessive water accumulation as well as the potential of fuel migration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 May 2024 Resolved
Suspected damage or deterioration to the hull plating that may affect the seaworthiness of the vessel. Fresh water tank / stern void, centerline, crop and renew affected structural area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 May 2024
Resolution: Plate will be replaced at next dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 May 2024 Resolved
Each towing vessel must have a fire-detection system. The system is arranged and installed so a fire in the engine room automatically sets off alarms on a fire detection control panel at the operating station. Vessel's panel at main operating station is inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 22 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 May 2024 Resolved
All towing vessels must operate in a manner that minimizes the risk of down flooding and progressive flooding. STBD side crew berthing hatch lower combing needs to be cropped and renewed. Change all gaskets on all hatches so gasket seam is at the top of each hatch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 22 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 May 2024 Resolved
Main engines must be equipped with an engine RPM gauge. Maine engines do not have an engine RPM gauge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 22 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 21 May 2024 No resolution recorded
The fuel shutoff valve must be installed in the fuel piping directly outside the fuel oil supply tank. Valves are not directly outside the fuel oil supply tank.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2024 Resolved
Vessel must have an approved 160-B semi-portable fire-extinguishing system to protect the engine room. Vessel's 160-B should be moved to outside the engine room.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2024
Resolved 22 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2023 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Vessel could not prove proper operation of the bilge pump. Repair / replace to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 June 2023
Resolved 3 July 2023
Resolution: Received video evidence of proper operation.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 June 2023 Resolved
Each towing vessel equipped with rudder(s) must have a means to monitor and control the position of the rudder(s) at each operating station. Vessels rudder position indicator is not operations. Repair / replace to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2023
Resolved 3 July 2023
Resolution: Received video evidence of proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 July 2022 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard main engine fuel filter sediment bowl flame shields had been removed. Required vessel to reinstall. 46 CFR 143.205(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: Flame shields on starboard main engine primary fuel filters were installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 July 2022 Resolved
Portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10. Paint locker extinguisher bracket was severely wasted. 46 CFR 142.240(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: New portable fire extinguisher bracket was installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 July 2022 Resolved
A power-driven vessel underway shall exhibit a stern light. Operational test of light found it inoperable. Either bulb or fixture is in need of repair/replacement. 33 CFR 83.23(a)(iv)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2022
Resolution: Stern light was repaired.
10 - Safety of Navigation › N/A - No Subsystem › Type approval equipment
Issued 5 July 2022 Resolved
Devices listed on ODAPC’s web page for “Approved Screening Devices to Measure Alcohol in Bodily Fluids” and EBTs listed on ODAPC’s web page for “Approved Evidential Breath Measurement Devices” are the only devices you are allowed to use to conduct alcohol screening tests. Alcohol test strips were not listed or approved. 46 CFR 4.06-15(a)(2) 49 CFR 40.229
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: DOT approved alcohol test strips were placed onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 July 2022 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operations prior to getting underway while considering current velocity/direction, water depth, and density of marine traffic. These must be recorded in the vessel's record book. 46 CFR 140.635(a)(1),(2), and (4) 46 CFR 140.915(a)(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: Voyage plan document was amended to capture required navigation assessment for the intended routes.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 July 2022 Resolved
Individuals, who are not crew members, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter. Vessel could not produce evidence that persons in addition to crew were being provided a safety orientation. 46 CFR 140.415
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2022
Resolution: Non crewmember orientation was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 February 2022 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems must: (1) be maintained to ensure proper operation; (2) be suitable for route and service; and (3) have suitable propulsion controls to provide the operator full control at each operating station. Port main engine failed. Make proper repairs or replace and prove proper operation prior to placing the vessel back in commercial service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 17 February 2022
Resolution: Received objective evidence port engine replaced in kind and tested satisfactorily.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 November 2021 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. A continuous supply of clean fuel must be provided to main propulsion engines and generators. The vessel loss power to the main generators due to rust in the fuel supply line. Please submit objective evidence of documented maintenance plan of the fuel system and operationally test the generator fuel system to the satisfaction of an attending CG Marine Inspector prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 November 2021
Resolution: Vessel resolved deficiencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2021 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings and electrical equipment and systems must be maintained to ensure proper operation. Port MDE overheated and seized as a result of a failed water pump. Repair or replace port MDE.
Action required: 705 - Other - as specified
Due 15 July 2021
Resolved 23 June 2021
Resolution: Renewed engine in kind. Test SAT.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 14 June 2021 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention to include main engine high cooling water temperature. The port main engine high cooling water temperature alarm did not sound when the engine's water pump failed resulting in the engine overheating to the point of failure. Prove proper operation of all machinery related alarms.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2021
Resolved 23 June 2021
Resolution: All alarms tested by RIO Marine. All bad sensors replaced and retested.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 April 2021 Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions. Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Alarm Set Points tested twice every 5 years, with no more than 3 years elapsing since last test. Vessel could not provide proof of testing the following alarm set-points. (1) Main engine low lubricating oil pressure; (2) Main engine high cooling water temperature; (3) Auxiliary generator engine low lubricating oil pressure; (4) Auxiliary generator engine high cooling water temperature Vessel will verify and test the alarm set-points to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 26 May 2021
Resolution: Recieved evidence of completion of testing alarm set points as required
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 April 2021 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Fuel filters must be replaced in accordance with manufacturer's requirements. Vessel did not have any documented maintenance plan for the main engine and generator fuel systems. Vessel will provide maintenance plan to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 26 May 2021
Resolution: Recieved a fuel maitenance plan
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2020 Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Both generators do not have lagging over exhaust manifolds, turbochargers, and portions of the exhaust pipe. Install lagging to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2020
Resolved 2 March 2020
Resolution: Exhaust lagging in place
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 January 2020 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Vessel was found with an excessive amount of oil in bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 30 January 2020
Resolution: Bilge was cleaned out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. Vessel was found with loose unfixed/unfastened steel fuel piping servicing the STBD MDE. Ensure piping is secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 30 January 2020
Resolution: Fuel piping properly secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Vessel battery box was found with unsecured battery. Secure battery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 30 January 2020
Resolution: Dunnage was used to properly secure battery within the box.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 January 2020 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Vessels SSDG was found with the crank case vent box/tube located over the generator windings causing excessive dirt and oil to accumulate on the generator. Reposition crank case vent tube/box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 30 January 2020
Resolution: Crank case vent was rerouted away from the windings.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 9 January 2020 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Vessel was missing adequate protection on the stern port and starboard sides. Install adequate grab rails to help prevent persons from falling overboard.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2020
Resolved 30 January 2020
Resolution: Grab lines (chains) were installed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2019 Resolved
Each Towing Vessel must be maintained and operated so as to minimize fire hazards. Vessel E/R is currently coated with oil creating an unsafe condition for personnel. Clean E/R and make available for post casualty inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2019
Resolution: Observed condition of engineroom was free of excess oil.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 27 March 2019 Resolved
Master must ensure all hatches and other opening designed to be weather tight function properly. Flush deck hatch to stbd steering gear room down flooded. Repair and make watertight prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2019
Resolution: Witnessed the four deck hatches onboard were replaced while in the shipyard on 01AUG19. Received pictures from vessel rep. which showed the four void spaces were free of water.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 27 March 2019 Resolved
Master of a towing vessel must ensure that all crewmembers are capable of performing duties during emergencies. Crew was unable to locate gas powered portable pump during flooding emergency. Provide evidence of training to USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2019
Resolution: Verified crew was able to locate gas powered portable pump. Witnessed satisfactory man overboard drill.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 March 2019 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency situation exists. The bilge high level alarm did not provide audible of visible indications when engine room began flooding. Provide working alarm system to satisfaction of attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2019
Resolution: Witnessed proper operation of bilge high level alarm.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.