Registered dimensions (L × B × D)94.0 ft × 25.1 ft × 9.0 ft
Registered tonnagegross 149 / net 101
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVERETT MARINE WAYS INC · EVERETT, WA, UNITED STATES · built 1944
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKETCHIKAN, AK
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 22 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it149 - Regulatory (Subpart C or D), Gross Ton 101 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 June 2024Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 1 July 2024
Resolution: Replaced expired items
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 June 2024Resolved
ALL CREWMEMBERS MUST BE FAMILIAR WITH THEIR FIRE-FIGHTING DUTIES, AND, SPECIFICALLY HOW TO...STOP ANY MECHANICAL VENTILATION SYSTEM FOR THE E/R AND EFFECTIVELY SEAL ALL NATURAL OPENINGS TO THE SPACE TO PREVENT LEAKAGE OF THE EXTINQUISHING AGENT...
E/R VENT HAS A HOLE FROM WASTAGE, PREVENTING ADEQUATE SEAL OF THE SPACE.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 1 July 2024
Resolution: Cropped and renewed wastage with insert
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 June 2024Resolved
EACH CABLE AND WIRE MUST BE SUPPORTED IN ORDER TO AVOID CHAFING OR OTHER DAMAGE.
AUX GEN BATTERY TERMINAL WIRE SHOWING INDICATION OF CHAFING AND FRAYING OF WIRES.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2024
Resolved 2 July 2024
Resolution: Replaced battery wires in kind
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 June 2023Resolved
DSC equipped radio is not receiving position data from installed navigation equipment. FCC regulations require this connection if navigational equipment is installed. Properly connect DSC radio to installed GPS.47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2023
Resolved 26 June 2023
Resolution: Position data provided.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 June 2023Resolved
Engine driven pully and belt on the No. 3 generator is exposed. Provide a suitable guard to prevent personnel injury. 46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2023
Resolved 26 June 2023
Resolution: Guards provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 June 2023Resolved
Fire and bilge remote switch on the stbd side weather deck is not rated for wet locations. Provide enclosure rated for weather locations. 46 CFR 143.400(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2023
Resolved 26 June 2023
Resolution: Control removed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 June 2023Resolved
Overhead light bulbs in the pilot house are unprotected. Provide guards or provide shatter proof bulbs. 46 CFR 143.410(a)
Action required: 10 - Deficiency Rectified
Due 9 June 2023
Resolved 9 June 2023
Resolution: Incandescent bulbs replaced with polymer LEDs.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 June 2023Resolved
Exhaust piping on both the No. 1 and No. 2 generators is missing. Provide lagging for all unjacketed exhaust pipe exceeding 220 C. 46 CFR 143.220(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2023
Resolved 26 June 2023
Resolution: Lagging provided.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 15 June 2022Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The valve must be installed in the fuel piping directly outside the fuel oil supply tank. Remote fuel shut off for the main diesel engines are located adjacent to the engine and not directly outside of the fuel tank.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Inspected new installation of remote fuel shut offs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2022Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Fuel filters in the engine room do not have flame impingement bowls (i.e. heat deflector kit).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 June 2022Resolved
Emergency lighting must be provided for all internal crew working and living areas to facilitate egress from each space and must be either: automatic, battery-operated with a duration of no less than 2 hours; or non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Vessel's emergency lighting was inoperable in the engine room and living areas.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2022Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location) and with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. The pressure relief valves are set at a pressure exceeding the MAWP of the air receivers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Verified correction.
The following systems must be equipped with gauges at the machinery location: main engine lube oil pressure, main engine RPM, main engine cooling water temperature, auxiliary generator lube oil pressure, auxiliary generator RPM, and auxiliary generator cooling water temperature. Vessel's #2 generator does not have an RPM gauge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Corrected.
The following alarms must be provided on each towing vessel: Main engine low lubricating oil pressure; Main engine high cooling water temperature; Auxiliary generator engine low lubricating oil pressure; and Auxiliary generator engine high cooling water temperature. Generators do not have low lube oil pressure or high jacket water temperature alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Provided.
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 15 June 2022Resolved
If your vessel is less than 300 gross tons and your vessel does not have the capacity to hold or
discharge more than 8 cubic meters (2113 gallons) of ballast water, you do not need to submit an
NOI. However, you must complete the PARI form found in Appendix K, and keep a copy of that
form onboard your vessel at all times. PARI form was not onboard. VGP 1.5.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 9 June 2023
Resolution: Corrected.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 28 February 2011Resolved
DER could not provide satisfactory EAP.
Action required: 705 - Other - as specified
Due 28 March 2011
Resolved 28 February 2011
Resolution: Satisfactory EAP provided to USCG.