Records from 2016 to 2024. Most recent: inspection, 6 April 2024.
Inspection history · 54
6 April 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7891054
6 April 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7902038
17 November 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826280
21 September 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7816843
4 September 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7784250
21 July 2023
MTSA/ISPS Verification · Administrative Inspection · COI Inspection · MSP COI Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7748083
22 June 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7721166
19 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671857
3 March 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7644829
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640528
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640535
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640542
22 February 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7640549
20 January 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7624252
16 January 2023
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7660617
1 November 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7587727
1 November 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591621
22 October 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7582988
22 October 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7710980
28 August 2022
Deficiency Check · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7450051
25 May 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7458903
7 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7363897
17 September 2021
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7314511
17 September 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7314552
14 September 2021
MSP Select Handover Survey · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7312489
21 August 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7294530
8 August 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7280934
22 July 2021
Underwater Inspection in lieu of Drydock
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7265848
16 July 2021
MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7270701
18 February 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7142689
10 August 2020
MSP Annual Oversight · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7033271
4 August 2020
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7025197
24 March 2020
Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6930805
22 January 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6924945
17 October 2019
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6796534
21 July 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6758523
21 July 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6763265
2 May 2019
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6674787
8 October 2018
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6557472
1 October 2018
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6552861
18 May 2018
MSP Initial Reflag
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6417463
10 May 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6410713
28 December 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6329808
6 December 2017
ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6319474
7 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6302661
1 July 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6192744
27 June 2017
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6188048
27 June 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6188872
18 June 2017
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6178383
2 May 2017
ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6133968
14 November 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040382
10 November 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6038722
16 June 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5908293
24 March 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5880667
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 April 2024
Resolved
A ship engaged in the carriage of dangerous goods in any cargo spaces shall be provided with a fixed carbon dioxide or inert gas fire-extinguishing system complying with the provisions of the Fire Safety Systems Code. Four feeder lines for the vessel's CO2 system serving the cargo holds were found to be fractured.
CITE: 74SOLAS(2009) II-2/10.7.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Deficiency has been referred to Class for clearing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2022
Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board. The vessel's cooling water pump caught on fire and was damaged. Replace/repair damaged pump and determine the cause of the casualty to prevent its recurrence to the satisfaction of RO and Coast Guard. Vessel shall have two assist tugs while maneuvering in port until item is rectified.
74 SOLAS (14) I/11.(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2022
Resolution: Received DNV survey report attesting the satisfactory repairs on the fresh-water pump motor.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 August 2022
Resolved
74 SOLAS (14) II-1/13-1.2
Access doors and access hatch covers normally closed at sea, intended to ensure the watertight integrity of
internal openings, shall be provided with means of
indication locally and on the bridge showing whether
these doors or hatch covers are open or closed. Local
indicators for SD-P08 and SD-P11 did not operate.
Bridge indicator constantly flickers on half the
indicators and dims when multiple doors are opened.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2022
Resolved 8 September 2022
Resolution: Accepted by class for action
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2022
Resolved
74 SOLAS (14) II-1/45.5.6
Terminations and joints in all conductors shall be so
made as to retain the original electrical, mechanical,
flame-retarding and, where necessary, fire-resisting
properties of the cable. Mi identified open/exposed
cables in crew laundry and an unknown 480V cable over
sea water pumps.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2022
Resolved 8 September 2022
Resolution: Accepted by class for action
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 August 2022
Resolved
74 SOLAS (14) III/11.4
Muster and embarkation stations shall be adequately
illuminated. MI found 2 lights at the Port embarkation
not working.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2022
Resolved 8 September 2022
Resolution: Accepted by class for action
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2022
Resolved
74 SOLAS (14) II-2/14.1.1
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use. MI
observed copper piping from pilot cylinders to CO2 bank
not connected.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 August 2022
Resolved 28 August 2022
Resolution: Vessel re-connected disconnected copper fitting and secured loose pilot line in brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 February 2021
Resolved
Every inflatable liferaft, inflatable lifejacket, and marine evacuation system shall be serviced:
.1 at intervals not exceeding 12 months, provided where in any case this is impracticable, the Administration may extend this period to 17 months. The vessel has exceeded their 12 month servicing requirements and shall have their liferafts serviced by a certified servicing facility within 5 months from February 2021.
74SOLAS(14) III/21.8.1.1
Action required: 705 - Other - as specified
Due 18 February 2021
Resolved 4 June 2021
Resolution: APL provided Liferaft certificates.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 10 August 2020
Resolved
An IOPP shall be issued iaw reg 6 to any ship above 400GT and shall be approved by administration or organization. Marine Inspector found IOPP to have invalid entry/approval for SOPEP/SMPEP. Provide correct IOPP.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 17 August 2020
Resolution: Def Cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 10 August 2020
Resolved
The ring, lines & letters shall be painted in white & yellow on dark ground and be plainly visible. Marine Inspector found loadline painted to be rubbed off/no longer contrasting color or visible. Provide properly marked load line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 23 September 2020
Resolution: Def Cleared
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 August 2020
Resolved
Navigation lights must meet the requirements of UL-1104. Marine inspector found fore and aft anchor lights to be inoperable. Prove proper operation of navigation lights panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 23 September 2020
Resolution: Def Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 10 August 2020
Resolved
Prior to leaving port and at all times during the voyage all life saving appliances shall be in working order and ready for immediate use. Due to inoperable ignition switch and malfunctioning battery switch for release hook mechanism stbd side lifeboat is inoperable. Prove proper operation of stbd lifeboat or provide alternate lifesaving equipment prior to departure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2020
Resolved 12 August 2020
Resolution: Def cleared
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 October 2019
Resolved
Before the ship leaves port & at all times during the voyage, all life-saving appliances shall be in working order & ready for immediate use. The port life boat could not be released from hooks by automatic release system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2019
Resolved 18 October 2019
Resolution: Repaired / Rectified: Found wrong power cable connection for electronic releasing system and
reconnected by DNV GL approved service company (Breakwater International).
The function test was carried out and found in order.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 October 2019
Resolved
Before the ship leaves port & at all times during the voyage, all life-saving appliances shall be in working order & ready for immediate use. The stbd life boat brake release wire was not properly feed through the boat for immediate use.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2019
Resolved 17 October 2019
Resolution: Vessel corrected on the spot by feeding brake wire through boat opening.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 17 October 2019
Resolved
The port life boat was missing cotter pins in both the fwd and aft shackles for the boat hooks.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 October 2019
Resolved 17 October 2019
Resolution: Vessel properly installed cotter pins.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 October 2019
Resolved
The condition of the ship and its systems equipment shall be maintained to conform with the present regulations. Multiple Cable Transits were found to be not properly installed/maintained IAW Type Approval. 03 Steering Gear to Aft Deck, 02 Port Tunnel to Aft Deck, 1st WTB FWD and 01 EDG OVHD.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 October 2019
Resolution: DNV GL accepted Deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 17 October 2019
Resolved
The company should establish procedures, plans, and instructions concerning safety of personnel, ship and environment. There is no management of required automation alarms. 35 Alarms were found to be in Offscan. 25 alarms were able to be cleared.
ISM 7
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 10 August 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 17 October 2019
Resolved
No Person may operate any vessel equipped woth installed toilet facilities unless it is equipped with a Type I,II, or III MSD. Vessels MSD is not CG Approved and found to be discharging overboard.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 October 2019
Resolved 17 October 2019
Resolution: Attending MI verified the crew was able to secure discharge pump. Closed all discharge valves to include locking the overboard skin valve.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 May 2018
Resolved
Witnessed testing/servicing of the E/R fixed CO2 time delay at 12 and 20 seconds. The CO2 fixed fire activation time delay shall “operate for the length of time needed to evacuate the space.” Install delay to minimum of 60 seconds and complete testing to satisfaction of attending [name withheld] 30 Sep 2018.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 8 October 2018
Resolution: Witnessed sat test of new 68 second time delay.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 May 2018
Resolved
During PSTP verification/spot check it was observed the PSTP was not accurate. Update PSTP and verify vessel system set points and submit to DNV-GL for approval and verification. Complete to satisfaction of the attending [name withheld] 30 SEP 2018.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 2 May 2019
Resolution: DNV-GL approved/verified PSTP 30JAN2019
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 18 May 2018
Resolved
Provide LRIT USCG conformance test report.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 August 2018
Resolved 30 August 2018
Resolution: Received report, clear def.
Fire Fighting › Fire Main › Condition
Issued 27 June 2017
Resolved
Fire fighting systems shall be maintained and ready for use. While offloading a container that was still partially secure, #2 hatch cover was raised and accidentally fell and caused damage to firemain and ruptured pipe reducing capability to fight a fire.
74SOLAS(CONS 2014)II-2/14.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: PSCO attended vessel and examined satisfactory repairs made to fire main piping.