Records from 1995 to 2026. Most recent: inspection, 15 January 2026.
Documentation record
Registered dimensions (L × B × D)104.8 ft × 40.0 ft × 18.0 ft
Registered tonnagegross 199 / net 135
ITC dimensions (L × B × D)104.8 ft × 40.0 ft × 18.0 ft
ITC tonnagegross 525 / net 157
BuilderTRINITY MARINE GROUP · LOCKPORT, LA, UNITED STATES · built 1995
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it199 - Regulatory (Subpart C or D), Gross Ton
525 - Convention (Subpart B), Gross Ton
135 - Regulatory (Subpart C or D), Net Ton
157 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 47
15 January 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8296501
3 June 2025
Vessel Attendance · Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8135801
19 November 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8027181
10 October 2022
Administrative Inspection · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7576414
6 October 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7572631
5 July 2022
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7496937
5 October 2021
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7327517
4 October 2021
In-Service Inspection · Administrative Inspection · Initial Certification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7326566
4 October 2021
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7326606
4 October 2021
Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7326685
28 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7184763
25 April 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7188175
21 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7180119
15 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7077988
9 October 2020
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7074580
3 September 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6532783
23 October 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6293046
16 October 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6290309
11 October 2017
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6339254
1 December 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6056935
24 August 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5987207
24 August 2016
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5987451
21 June 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5914205
25 March 2016
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5840448
24 March 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5880667
2 October 2015
Marine Casualty Follow Up
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5734515
31 August 2015
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5234722
7 April 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4840511
3 April 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4841422
6 February 2013
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4532587
13 December 2011
MARPOL · Deficiency Check · Industry Initiated Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4207453
8 November 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4185446
20 June 2011
Marine Casualty Follow Up
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4064129
13 June 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4060320
27 April 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3998122
21 September 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3602875
12 December 2008
Administration
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3380616
7 November 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2815839
2 March 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2018143
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971068
5 January 2003
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1735865
20 September 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 821998
5 May 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1098197
1 May 1997
Uninspected Towing Vessel
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1097220
23 July 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 119383
23 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 703684
16 August 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 87077
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2024
Resolved
Flammable and combustible products must not be stored in machinery spaces, unless they are stored in a suitable container that meets the requirements of § 142.225 of this subchapter. Flammable liquids were observed to have been stored in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 November 2024
Resolved
The following systems must be equipped with gauges at the machinery location: Auxiliary generator engine lubricating oil pressure. Starboard SSDG lube oil gauge was inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 November 2024
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. A broken wire was observed for one of the masthead lights on the starboard side of the mast.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2024
Resolved
Each lifejacket must be marked:(1) In block capital letters with the name of the vessel. Some of the lifejackets on board are not marked properly with the name of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 November 2024
Resolved
Where practicable and except as provided in § 144.515, each space where crew may be quartered or normally employed must have at least two means of escape.
Arrangements on an existing vessel may be retained if itis impracticable or unreasonable to provide two means of escape. Forward escape broken and unable to open.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 19 November 2024
Resolved
Any towing vessel with alternating watches (shift work) or overnight accommodations must identify the duties and duty stations of each person onboard during an emergency. Emergency duties for persons other then crew is not posted on emergency station bill.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2024
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Pressure vessel relief valves next to compressors have not been tested since 2019.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 November 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical distribution panel #3 missing breaker and has opening for shock hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2024
Resolution: Received photo evidence from operator of deficiency being rectified.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 24 August 2016
Resolved
Repair and prove proper operation of starboard MDE prior to operating.
Due 24 August 2016
Resolved 29 August 2016