Records from 1998 to 2026. Most recent: inspection, 24 July 2026.
Inspection history · 62
24 July 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8445329
17 April 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8351483
5 March 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8320316
13 February 2026
Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8310371
5 February 2026
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8306775
29 April 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8123040
18 March 2025
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8095835
12 November 2024
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8034179
26 October 2024
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8025150
21 May 2024
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7916378
6 March 2023
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7646132
4 January 2023
Drydock Exam · Load Line/Change of Employment · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7616440
18 October 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7579799
12 October 2022
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7575743
6 October 2022
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7608414
31 May 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7464095
22 January 2021
Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7128833
3 April 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6933994
22 February 2019
MARPOL Annex I Examination · Deficiency Check · Annual Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6629529
11 January 2018
Administrative Inspection · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6351280
21 June 2017
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6182890
21 June 2017
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6184295
27 April 2017
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6133771
21 April 2017
Damage Survey · Permit to Proceed
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6130042
27 February 2017
MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6095684
19 November 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6049319
11 January 2016
MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5795336
28 April 2015
MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5112543
22 May 2014
Administrative Inspection · Welding Related Inspections Qualification Testing · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4865005
3 April 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4841422
30 January 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4791738
17 June 2013
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4622936
5 April 2012
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4282328
25 November 2010
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3900473
26 February 2010
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3686741
26 January 2010
Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3670337
24 June 2009
Spot Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3512514
6 November 2008
MARPOL Annex II Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360559
10 January 2008
Internal Structural Exam · MARPOL Annex I Examination · Annual Inspection · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3131948
19 September 2007
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3061248
26 July 2007
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3008210
20 December 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2843453
8 November 2006
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2816634
8 May 2006
MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2643811
21 March 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2606616
23 February 2006
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2590692
25 January 2006
Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2573262
28 December 2005
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2557264
28 July 2005
COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2442585
16 May 2005
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2358906
17 December 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1965833
30 October 2003
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1939115
4 March 2003
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1752391
17 June 2002
Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1631839
9 January 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476527
12 January 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1418814
28 December 2000
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 825214
25 November 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 18534
6 April 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048345
6 January 2000
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1432232
5 January 1999
Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1372450
14 January 1998
Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434664
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 April 2025
Resolved
Current ABS Stability letter dated 2019 not present. Older copy onboard. Place current Stability letter in vessels document folder per 46 CFR 42.15-5.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 30 April 2025
Resolution: ABS Surveyor provided copy of current letter.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2025
Resolved
Current USCG Vessel Security letter, dated 2024 not present. Older outdated copy onboard. Place current Security letter in vessels document folder per 46 CFR 178.230.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 29 April 2025
Resolution: Copy of current VSL e-mailed to vessel rep. Rep stated copy would be placed in vessels document binnder. Def Cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2025
Resolved
Original COI not onboard. Original COI required to be onboard or in vessel document binder per 46 CFR 91.01-5.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 29 April 2025
Resolution: Amended COI submitted for Sector Jax OCMI signature. Once signed, amended COI will be delivered to company rep, and placed in vessels binder.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 April 2025
Resolved
Observed workers cut a 16 inch by 14 inch insert in fwd forward WTB, apx 6 feet inboard of the stbd fwd wtd. Company rep & ABS Surveyor stated area wasted. Insert to be cropped, renewed to satisfaction of attending Class Surveyor. To be rectified before vessels departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 30 April 2025
Resolution: e-mail with statement & photo provided by attending class surveyor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2025
Resolved
The vessel owner or operator must ensure the implementation of security measures and have the capability to continuously monitor... as specified in their approved Vessel Security Plan.
The VSP states that the will be deck appropriately illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 1 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2025
Resolved
The CSO or VSO must ensure an audit of the VSP is performed...
The USCG marine inspector is requesting a security audit of section 6.0 of the approved VSP. Send proposed amendments and a risk assessments of how the proposed amendments will be implemented to this office for review and acceptance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 13 February 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 January 2021
Resolved
701c - For vessels assigned a load line, see chapter E(Load Lines) of this chapter, for special requirements as to strength, closure of openings, etc.
During inspection, Marine Inspectors observed structural damage within the Port Forward Peak and Starboard Aft voids. Damage was severe enough that the barge will probably need to go to dry dock.
Provide a repair proposal. 46 CFR 92.01-5(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Barge completed repairs ABS witness
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 3 April 2020
Resolved
The load line rings, lines and letters shall be painted in white or yellow on a dark ground or black on a light ground. Vessel needs to paint load line so that it is visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2020
Resolved 5 April 2020
Resolution: Verified load line has been painted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2019
Resolved
All exposed openings in the hull must be made watertight. Identified multiple broken studs on hatch access openings. Install new studs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2019
Resolved 10 April 2019
Resolution: Inpected barge man hole covers all found SAT
Construction/Loadline › Hull › Side Shell
Issued 21 June 2017
Resolved
Prove structural integrity of forward rake, stbd rake, & #1 center tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2017
Resolved 22 June 2017
Resolution: No damage found internally by MI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 January 2016
Resolved
Crop and replace upper diagonal support frames 21 and 22 in the #4 port tank. (Picture taken of diagonal frame 21 and attached to this activity)
Crop and replace ladders in #8 port (aft), #8 center (aft), #8 starboard (aft), #6 starboard(forward) and #1 starboard(forward).
Repair ladder mounting on #8 port (forward) and #6 port (forward) ladders.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 8 March 2016
Resolution: Vessel completed required repairs.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 January 2010
Resolved
Provide clear & visible draft and loadline marks on stbd side of vessel IAW regulations.
Condition: Unknown
Due 26 February 2010
Resolved 26 February 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 26 January 2010
Resolved
Repair handrails on stbd bow breakwater aft of the stbd winch IAW regulations.
Condition: Unknown
Due 26 February 2010
Resolved 26 February 2010
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 24 June 2009
Resolved
Vsl had diesel fuel loaded within the ballast tanks of a vessel secured on deck as cargo.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Deck/Cargo › Cargo Stowage › General
Issued 24 June 2009
Resolved
Vsl had diesel fuel loaded within the ballast tanks of a Lift Boat secured on deck as cargo.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 November 2006
Resolved
Replace rails lifelines and bent stations as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: Lifelines and rails were replaced.
Construction/Loadline › Structures › Door
Issued 8 November 2006
Resolved
Dogs are frozen on both doors. Perform PMS on both watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: PMS performed, dogs are working fine.
Construction/Loadline › Structures › Door
Issued 8 November 2006
Resolved
Renew the gasket in the portside watertight door.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: Gasket is replaced.
Construction/Loadline › Markings › Load Line Mark
Issued 26 January 2006
Resolved
Paint load line a contrasting color.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 26 January 2006
Resolved
Renew or repair the forward day shape support stanchion.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2006
Resolved
Have all nav lights show the proper arc of visibility, current shades on the forward and aft lights limit the arc to approx 90 degrees.
Condition: Design Flaw
Due 28 February 2006
Resolved 23 February 2006
Deck/Cargo › Mooring/Anchoring › Winch
Issued 26 January 2006
Resolved
Renew all fasteners for the forward port and starboard winches. Current mounting bolts are wasted.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2003
Resolved
INSTALL TWO COURSES OF HANDRAIL WITH CONNECTIONS TO STANCHION ON PERIMETER OF BARGE (WHERE MISSING). LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 17 December 2003
Electrical › Electric Supply System (service)
Issued 30 October 2003
Resolved
PROPERLY SECURE AND RENEW BATTERY BOXES FOR NAVIGATION LIGHTS. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 30 October 2003
Documentation
Issued 14 January 1998
Resolved
PROVIDE A COPY OF SOPEP APPROVAL LETTER TO [name withheld].
Condition: Unknown
Due 14 February 1998
Resolved 21 January 1998