MAURY USCG vessel records
← All vessels

SHUGART BRIDGE

SHUGART BRIDGE is a 1997 freight barge. The Coast Guard has recorded 62 inspections since 1998, most recently in July 2026, along with 25 deficiencies, 3 operational controls and 6 casualty investigations between 2007 and 2022.

Records from 1998 to 2026. Most recent: inspection, 24 July 2026.

Built
1997
Last inspected
24 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 July 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 27 calendar years (1998–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

464368
Flag
UNITED STATES
Maury page id
psix-464368

Documentation record

Registered dimensions (L × B × D)379.8 ft × 100.0 ft × 21.5 ft
Registered tonnagegross 5,860 / net 1,758
ITC dimensions (L × B × D)379.8 ft × 100.0 ft × 21.5 ft
ITC tonnagegross 5,860 / net 1,758
BuilderGULF COAST FABRICATION INC · PEARLINGTON, MS, UNITED STATES · built 1997
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJACKSONVILLE, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1758 - Convention (Subpart B), Net Ton
5860 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 62

24 July 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8445329
17 April 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8351483
5 March 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8320316
13 February 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8310371
5 February 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8306775
29 April 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8123040
18 March 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8095835
12 November 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8034179
26 October 2024 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8025150
21 May 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7916378
6 March 2023 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7646132
4 January 2023 Drydock Exam · Load Line/Change of Employment · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7616440
18 October 2022 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7579799
12 October 2022 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7575743
6 October 2022 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7608414
31 May 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7464095
22 January 2021 Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7128833
3 April 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6933994
22 February 2019 MARPOL Annex I Examination · Deficiency Check · Annual Inspection · MTSA Verification · MARPOL Annex VI Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6629529
11 January 2018 Administrative Inspection · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6351280
21 June 2017 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6182890
21 June 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6184295
27 April 2017 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6133771
21 April 2017 Damage Survey · Permit to Proceed
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6130042
27 February 2017 MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6095684
19 November 2016 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6049319
11 January 2016 MARPOL Annex I Examination · Annual Inspection · Internal Structural Exam · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5795336
28 April 2015 MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5112543
22 May 2014 Administrative Inspection · Welding Related Inspections Qualification Testing · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4865005
3 April 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4841422
30 January 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4791738
17 June 2013 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4622936
5 April 2012 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4282328
25 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3900473
26 February 2010 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3686741
26 January 2010 Annual Inspection · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3670337
24 June 2009 Spot Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3512514
6 November 2008 MARPOL Annex II Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3360559
10 January 2008 Internal Structural Exam · MARPOL Annex I Examination · Annual Inspection · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3131948
19 September 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3061248
26 July 2007 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3008210
20 December 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2843453
8 November 2006 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2816634
8 May 2006 MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2643811
21 March 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2606616
23 February 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2590692
25 January 2006 Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2573262
28 December 2005 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2557264
28 July 2005 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2442585
16 May 2005 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2358906
17 December 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1965833
30 October 2003 Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1939115
4 March 2003 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1752391
17 June 2002 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1631839
9 January 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1476527
12 January 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1418814
28 December 2000 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 825214
25 November 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 18534
6 April 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1048345
6 January 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1432232
5 January 1999 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1372450
14 January 1998 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434664

Deficiency record · 25

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 April 2025 Resolved
Current ABS Stability letter dated 2019 not present. Older copy onboard. Place current Stability letter in vessels document folder per 46 CFR 42.15-5.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 30 April 2025
Resolution: ABS Surveyor provided copy of current letter.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2025 Resolved
Current USCG Vessel Security letter, dated 2024 not present. Older outdated copy onboard. Place current Security letter in vessels document folder per 46 CFR 178.230.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 29 April 2025
Resolution: Copy of current VSL e-mailed to vessel rep. Rep stated copy would be placed in vessels document binnder. Def Cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2025 Resolved
Original COI not onboard. Original COI required to be onboard or in vessel document binder per 46 CFR 91.01-5.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 29 April 2025
Resolution: Amended COI submitted for Sector Jax OCMI signature. Once signed, amended COI will be delivered to company rep, and placed in vessels binder.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 29 April 2025 Resolved
Observed workers cut a 16 inch by 14 inch insert in fwd forward WTB, apx 6 feet inboard of the stbd fwd wtd. Company rep & ABS Surveyor stated area wasted. Insert to be cropped, renewed to satisfaction of attending Class Surveyor. To be rectified before vessels departure.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2025
Resolved 30 April 2025
Resolution: e-mail with statement & photo provided by attending class surveyor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2025 Resolved
The vessel owner or operator must ensure the implementation of security measures and have the capability to continuously monitor... as specified in their approved Vessel Security Plan. The VSP states that the will be deck appropriately illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2025
Resolved 1 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 March 2025 Resolved
The CSO or VSO must ensure an audit of the VSP is performed... The USCG marine inspector is requesting a security audit of section 6.0 of the approved VSP. Send proposed amendments and a risk assessments of how the proposed amendments will be implemented to this office for review and acceptance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 13 February 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 22 January 2021 Resolved
701c - For vessels assigned a load line, see chapter E(Load Lines) of this chapter, for special requirements as to strength, closure of openings, etc. During inspection, Marine Inspectors observed structural damage within the Port Forward Peak and Starboard Aft voids. Damage was severe enough that the barge will probably need to go to dry dock. Provide a repair proposal. 46 CFR 92.01-5(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2021
Resolution: Barge completed repairs ABS witness
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 3 April 2020 Resolved
The load line rings, lines and letters shall be painted in white or yellow on a dark ground or black on a light ground. Vessel needs to paint load line so that it is visible.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2020
Resolved 5 April 2020
Resolution: Verified load line has been painted
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2019 Resolved
All exposed openings in the hull must be made watertight. Identified multiple broken studs on hatch access openings. Install new studs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2019
Resolved 10 April 2019
Resolution: Inpected barge man hole covers all found SAT
Construction/Loadline › Hull › Side Shell
Issued 21 June 2017 Resolved
Prove structural integrity of forward rake, stbd rake, & #1 center tank.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2017
Resolved 22 June 2017
Resolution: No damage found internally by MI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 January 2016 Resolved
Crop and replace upper diagonal support frames 21 and 22 in the #4 port tank. (Picture taken of diagonal frame 21 and attached to this activity) Crop and replace ladders in #8 port (aft), #8 center (aft), #8 starboard (aft), #6 starboard(forward) and #1 starboard(forward). Repair ladder mounting on #8 port (forward) and #6 port (forward) ladders.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 March 2016
Resolved 8 March 2016
Resolution: Vessel completed required repairs.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 January 2010 Resolved
Provide clear & visible draft and loadline marks on stbd side of vessel IAW regulations.
Condition: Unknown
Due 26 February 2010
Resolved 26 February 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 26 January 2010 Resolved
Repair handrails on stbd bow breakwater aft of the stbd winch IAW regulations.
Condition: Unknown
Due 26 February 2010
Resolved 26 February 2010
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 24 June 2009 Resolved
Vsl had diesel fuel loaded within the ballast tanks of a vessel secured on deck as cargo.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Deck/Cargo › Cargo Stowage › General
Issued 24 June 2009 Resolved
Vsl had diesel fuel loaded within the ballast tanks of a Lift Boat secured on deck as cargo.
Action required: 705 - Other - as specified
Resolved 25 June 2009
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 8 November 2006 Resolved
Replace rails lifelines and bent stations as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: Lifelines and rails were replaced.
Construction/Loadline › Structures › Door
Issued 8 November 2006 Resolved
Dogs are frozen on both doors. Perform PMS on both watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: PMS performed, dogs are working fine.
Construction/Loadline › Structures › Door
Issued 8 November 2006 Resolved
Renew the gasket in the portside watertight door.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 December 2006
Resolved 20 December 2006
Resolution: Gasket is replaced.
Construction/Loadline › Markings › Load Line Mark
Issued 26 January 2006 Resolved
Paint load line a contrasting color.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 26 January 2006 Resolved
Renew or repair the forward day shape support stanchion.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 January 2006 Resolved
Have all nav lights show the proper arc of visibility, current shades on the forward and aft lights limit the arc to approx 90 degrees.
Condition: Design Flaw
Due 28 February 2006
Resolved 23 February 2006
Deck/Cargo › Mooring/Anchoring › Winch
Issued 26 January 2006 Resolved
Renew all fasteners for the forward port and starboard winches. Current mounting bolts are wasted.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 23 February 2006
Accommodation/Occupational Safety › Occupational Safety
Issued 30 October 2003 Resolved
INSTALL TWO COURSES OF HANDRAIL WITH CONNECTIONS TO STANCHION ON PERIMETER OF BARGE (WHERE MISSING). LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 17 December 2003
Electrical › Electric Supply System (service)
Issued 30 October 2003 Resolved
PROPERLY SECURE AND RENEW BATTERY BOXES FOR NAVIGATION LIGHTS. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 18 December 2003
Resolved 30 October 2003
Documentation
Issued 14 January 1998 Resolved
PROVIDE A COPY OF SOPEP APPROVAL LETTER TO [name withheld].
Condition: Unknown
Due 14 February 1998
Resolved 21 January 1998

Casualty record · 6

19 September 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3061248
3 April 2014Routine · role: Involved in a Marine Casualty · activity 4841422
19 November 2016Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 6049319
21 June 2017Routine · role: Involved in a Marine Casualty · activity 6184295
6 October 2022Routine · role: Involved in a Marine Casualty · activity 7608414
18 October 2022Routine · role: Involved in a Marine Casualty · activity 7579799
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CHICAGO BRIDGE (2007–2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.