Records from 1998 to 2025. Most recent: inspection, 11 April 2025.
Inspection history · 35
11 April 2025
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8110142
24 March 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8098700
16 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8047935
11 March 2024
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7877172
20 December 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7841216
7 February 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7633495
7 February 2022
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7392082
13 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7367199
17 March 2021
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7157796
29 April 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6945629
9 December 2019
COE-Administrative · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6870601
16 April 2019
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6663357
12 April 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6675305
4 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6656093
8 October 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6568882
16 April 2018
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6399791
5 March 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6365847
6 December 2017
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6319656
1 June 2017
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6166714
15 March 2016
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5818309
16 December 2011
Simplified Stability Test
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4209619
14 December 2010
Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3925045
10 December 2010
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3909484
14 December 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3650093
15 December 2008
Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3369142
18 January 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3132871
11 January 2006
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2564225
8 December 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2254515
28 November 2003
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1955625
24 June 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1825765
12 June 2003
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1816100
16 November 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1461450
7 April 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 817177
18 January 2000
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1420264
24 November 1998
Hull Examination · Initial Certification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1402754
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 February 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring buoy at operating station found with severed/degraded grab lines and water light line. Replace lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 February 2023
Resolved 8 February 2023
Resolution: Ring buoy replaced along with all lines and light.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 7 February 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years.If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. Certificate found expired. Renew Certificate.
47 CFR 80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 13 February 2023
Resolution: Received copy of newly issued bridge to bridge certificate
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 February 2023
Resolved
Fire extinguishers shall be inspected either manually
or by means of an electronic monitoring device/system at a minimum of 30-day intervals. No record of inspection found onboard. Inspect all portable fire extinguishers,
record appropriately, and provide evidence of inspection
to the Coast Guard.
NFPA 10/7.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 13 February 2023
Resolution: Received photographs indicating extinguishers have been inspected and properly recorded.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 7 February 2023
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include - (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Marine Inspector could not verify position of the valve as open or closed. Provide evidence to confirm valve is closed and secured.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2023
Resolved 8 February 2023
Resolution: Overboard valve closed, labeled, and secured via wire.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2021
Resolved
46 CFR 179.320(c)
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
There are 02 bulkhead penetrations from the engine room to the next space aft that are not made permanently watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 5 April 2021
Resolution: Vessel installed temporary patches in the bulkhead penetrations. Will affect permanent weld repairs in next drydock. Entered into special notes.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 March 2021
Resolved
46 CFR 181.120(a)
Fire extinguishing equipment installed on a vessel in excess of the requirements of 46 CFR 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4).
The installed fire pump is inoperable. Any equipment installed, must be in proper working order.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 5 April 2021
Resolution: Vessel installed new fire pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 March 2021
Resolved
46 CFR 179.360
Each hatch exposed to the weather must be watertight.
The forward emergency exit hatch will not fully seat, allowing for the chance for down flooding.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 26 April 2021
Resolution: Witnessed operation of forward emergency exit escape hatch fully seating and locking.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2021
Resolved
46 CFR 182.455(b)(4)
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow.
The port side fuel shutoff valve will not fully close when the emergency fuel shutoff handle is actuated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 5 April 2021
Resolution: Witnessed operation of fuel shutoff valve after adjustments were made, allowing the valve to fully close.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 17 March 2021
Resolved
46 CFR 184.420(a)(1)
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible.
Vessel utilizes electronic charts as primary navigation source. Current electronic charts are out of date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 26 April 2021
Resolution: Witnessed operation of electronic chart system and verified that electronic charts were up to date.
Electrical › Electric Supply System (service) › Cable
Issued 11 January 2011
Resolved
Improper wire splices
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 20 January 2011
Resolution: Replaced splices with proper IEEE std
Engineering › Feedwater/Condensate Water System › Gauge
Issued 11 January 2011
Resolved
Raw water temp gauge not working
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 20 January 2011
Resolution: Replaced water temp gauge at operating station
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 December 2010
Resolved
Prior to operation provide proof of service to pre engineered wet chem system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 20 January 2011
Resolution: Recieved system servicing report including engine shutdown components.
Lifesaving › Lifebuoys › Approval
Issued 14 December 2010
Resolved
Provide ring buoy IAW 46CFR180.70
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 20 January 2011
Resolution: Installed ring buoy IAW 46CFR180.70
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 14 December 2009
Resolved
Machinery guard on the generator is missing.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: New guards were installed.
Engineering › Bilge Water Management System › Not Operational
Issued 14 December 2009
Resolved
Forward & midship bilge alarms not functional.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: All alarms are operational.
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2009
Resolved
Provide caps on all missing penetrations on deck.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: All missing caps were in place.
Navigation › Piloting/Steering › Marine Charts
Issued 14 December 2009
Resolved
Update charts and maintain corrections.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: Updated charts were on board the vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2009
Resolved
Remove all dead end wires from E/R.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: All dead end wires were removed.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 14 December 2009
Resolved
Replace frayed anchor line.
Action required: 705 - Other - as specified
Due 14 January 2010
Resolved 21 December 2009
Resolution: Anchore line was to the satifaction of the attending OCMI.
Stability › Watertight Integrity › General
Issued 15 December 2008
Resolved
Covers to E/R bulkhead vent openings to make space watertight IAW 46 CFR 179.210
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 28 January 2009
Resolution: Corrections made.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2008
Resolved
First aid kit was expired.
Condition: Improper/Lack of Maintenance
Due 22 January 2008
Resolved 29 January 2008
Resolution: New first aid kit provided
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 January 2008
Resolved
Vessel did not have onboard, CG Light list, Coast Pilot, Tide tables and current tables. Up to date chart 11323 Galveston approach.
Condition: Unknown
Due 22 January 2008
Resolved 29 January 2008
Resolution: New publication provided
Personnel › Certificates/Documents/Licenses
Issued 13 June 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 20 June 2003
Resolved 24 June 2003
Engineering
Issued 13 June 2003
Resolved
Install guard on generator v-belts/pullys. (46CFR177.960)
Due 20 June 2003
Resolved 24 June 2003
Communications › Alarms/Indicators
Issued 13 June 2003
Resolved
Demonstrate proper operation of all bilge high level alarms. (46CFR182.530) LEGACY COMPONENT DESC: Bilge Alarm
Due 20 June 2003
Resolved 24 June 2003
Lifesaving › Buoyant Apparatus
Issued 13 June 2003
Resolved
Properly install sea painter on life floats. LEGACY COMPONENT DESC: Sea painter
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2003
Resolved 13 June 2003
Engineering
Issued 13 June 2003
Resolved
Permanently mount bilge pump in rudder room. (46CFR182.520(e)(3) LEGACY COMPONENT DESC: Bilge pump
Due 20 June 2003
Resolved 24 June 2003
Construction/Loadline › Penetrations
Issued 12 June 2003
Resolved
Install shut off valves on all bilge pump discharge hull penetrations. (46CFR182.520(e)(7) LEGACY COMPONENT DESC: shut off valves
Due 20 June 2003
Resolved 24 June 2003
Accommodation/Occupational Safety
Issued 18 January 2000
Resolved
REPLACE CRACKED SAFETY GLASS IN STARBOARD SIDE WINDOW IN WAY OF MAIN CABIN.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Lifesaving
Issued 18 January 2000
Resolved
PROVIDE ON BOARD 1 ADDITIONAL ORANGE SMOKE SIGNAL FOR A TOTAL OF THREE.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 18 January 2000
Resolved
REPLACE PLSTIC WIRE TIE SUPPORTS WITH METAL SUPPORTS IN ENGINE ROOM.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Navigation
Issued 18 January 2000
Resolved
RREPAIR, REPLACE OR REMOVE NON TRANSMITTING VHF-FM RADIO LOCATED ON PORT OUTBOARD SIDE OF BRIDGE.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000
Electrical
Issued 18 January 2000
Resolved
PROVE SATISFACTORY OPERATION OF EMERGENCY LIGHTING SYSTEM IN WAY OF FORWARDLOWER ACCOMODATION AREA.
Condition: Unknown
Due 18 January 2000
Resolved 18 January 2000