MAURY USCG vessel records
← All vessels

GRACE MYRICK

Built
1974
Last inspected
27 June 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 27 June 2025
…with no type recorded19
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1994–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8495
131700
Flag
UNITED STATES
Maury page id
psix-131700

Documentation record

Registered dimensions (L × B × D)60.3 ft × 22.0 ft × 8.1 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCULLY BROS BOAT BLDG INC · STEPHENSVILLE, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWILMINGTON, DE
Endorsements, as the file codes themcw_un
DocumentationValid · issued 13 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 37 inspections, each with its date, unit and type; 42 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 18 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 18

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STEVENS 1601 Freight Barge · MISLE 44785 · 17 December 2020 · activity 7114646MISS LEANNE Towing Vessel · MISLE 860634 · 17 December 2020 · activity 7114646PROUD MARY Towing Vessel · MISLE 910241 · 17 December 2020 · activity 7114646IN1608BZ Research Vessel · MISLE 995525 · 17 December 2020 · activity 7114646MYRICK13060 Freight Barge · MISLE 1434852 · 17 December 2020 · activity 7114646GONSOULIN 203 Tank Barge · MISLE 437709 · 10 August 2012 · activity 4416877LBT 60 Tank Barge · MISLE 42799 · 8 May 2001 · activity 126055COASTAL DAWN Towing Vessel · MISLE 197451 · 8 May 2001 · activity 126055CBC 760 Freight Barge · MISLE 438553 · 8 May 2001 · activity 126055CREOLE 7 Industrial Vessel · MISLE 50805 · 8 July 1995 · activity 166546LSC 52 Tank Barge · MISLE 51285 · 8 July 1995 · activity 166546LBT 60 Tank Barge · MISLE 42799 · 6 April 1994 · activity 83400LBT 61 Tank Barge · MISLE 42806 · 6 April 1994 · activity 83400ITEL 101 Freight Barge · MISLE 167884 · 6 April 1994 · activity 83400CGB 426B Freight Barge · MISLE 331281 · 6 April 1994 · activity 83400AEP 3452 Freight Barge · MISLE 398401 · 6 April 1994 · activity 83400AEP 3453 Freight Barge · MISLE 398402 · 6 April 1994 · activity 83400AEP 3454 Freight Barge · MISLE 398403 · 6 April 1994 · activity 83400AEP 3455 Freight Barge · MISLE 398404 · 6 April 1994 · activity 83400

Inspection history · 37

27 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8168606
15 July 2024 Hull Examination · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7953663
20 June 2024 MTSA Verification · COI Inspection · Examination of Repairs · DAPI Audit
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7938844
18 September 2023 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7763800
31 August 2022 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7542748
8 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7302475
17 December 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7114646
16 September 2020 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7059100
25 August 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7031671
22 April 2019 Initial Certification · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6667311
14 September 2017 MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6265661
13 December 2016 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6057562
13 January 2014 Marine Casualty Follow Up
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4784954
8 January 2014 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4784024
22 August 2013 Marine Casualty Follow Up
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4694157
18 July 2013 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4658067
12 June 2013 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4622789
21 February 2013 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4536707
3 October 2012 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4476947
10 August 2012 Marine Casualty Follow Up · DAPI Audit
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4409389
10 August 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4416877
27 December 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4283493
28 November 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4197910
8 November 2010 Deficiency Check · MTSA Verification · Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3886933
2 December 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3377183
27 September 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368622
14 July 2005 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2622130
16 June 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2392677
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963373
8 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 126055
8 July 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 166546
12 April 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665366
21 March 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 709729
8 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212270
8 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213639
8 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214408
6 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83400

Deficiency record · 42

03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2025 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The vessels watertight doors would not dog down properly. Master needs to make sure all dogs are adjusted appropriately and the proper door seals are installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 6 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 July 2025 Resolved
Essential systems or equipment must be regularly tested and examined. Company needs to show proof of last time alarm set points were performed and Master needs to record testing of essential all essential equipment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2025
Resolved 6 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2024 Resolved
During an inspection of the tail shaft, it was noted that both cutlass bearings showed uneven wear. Replace both cutlass bearings in way of the tail shafts prior to credit for dry dock.
Action required: 705 - Other - as specified
Resolved 19 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2024 Resolved
Unable to conduct an inspection of the sea chest do to the blocking when the vessel was hauled out. There is only one raw water intake for this vessel for use with the fire/bilge pump. Make the valve available for inspection by a Coast Guard Marine Inspector prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 12 August 2024
Resolution: A new ball valve was fitted as was a new strainer over the sea chest.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 July 2024 Resolved
During an inspection in the lazarette, observed one transverse stiffener wasted and the adjoining gusset tripped. Crop and renew the wasted stiffener and gusset to the satisfaction of an attending Coast Guard Marine Inspector. This item is not required to be completed prior to credit dry dock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2024
Resolved 19 August 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2024 Resolved
A towing vessel that is: Certificated for rivers, lakes, bays, and sounds, less than 3 nautical miles from shore on the Great Lakes whose contract for construction was executed prior to August 27, 2003 must be equipped with either:An approved 160-B semi-portable fire-extinguishing system to protect the engine room; or A fixed fire-extinguishing system installed to protect the engine room. Vessel's 160-B had a nozzle fitting that was extremely deteriorated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2024
Resolution: Replaced hose and nozzle
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2024 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110, unless the towing vessel is limited to daytime operation, in which case no floating electric water light is required. All waterlights for the ring buoys onboard had deteriorated lines and the stbd ring buoy light had the wrong type battery installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 July 2024
Resolution: Rreplaced all.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2024 Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. The engine room bilge suction valve was leaking due to packing and or tightness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 22 August 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 July 2024 Resolved
Ensure all items that are required in the TVR are carried out and then recorded in accordance with 46 CFR 140.915(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 22 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Stbd main engine outboard cylinder head cover blow by had an extreme amount of exhaust fumes escaping due to bad cylinders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 5 July 2024
Resolution: Piped exhaust outside engine room until cylinder parts are aquired and repairs are made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 July 2024 Resolved
Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions. Vessel's port generator would not start due to bad cell in battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 5 July 2024
Resolution: Replaced battery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Vessel's Amperage Meter on the switchboard was broken and inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 22 August 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 July 2024 Resolved
Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Vessel's weathertight door gaskets are worn and need replacing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2024
Resolved 22 August 2024
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 1 July 2024 Resolved
Each towing vessel must verify the set points on all engine alarms and conduct an operational test of each alarm set point, twice in every five year period with no more than three years between the verification in accordance with 46 CFR 142.245(b). The vessel had a third party verify and test the alarm set points for the main engines and auxiliary generators but there was no entry recorded in the TVR for completion of these verifications and tests neither was there any documentation from the third party. Provide documentation confirming the set points and alarm tests are verified and completed and then make an entry into the TVR on the date this was performed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2024
Resolved 22 August 2024
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 18 September 2023 Resolved
This towing vessel subject to bridge to bridge requirements in accordance with 33 CFR 26.03(a)(3) must maintain a radio station log as prescribed by 47 CFR 80.409(f)(3). The Radiotelephony record logs entries must include all the requirements of 47 CFR 80.409 paragraphs (e)(1), (3), (5) (6), (7), (10), and (11). Provide and properly maintain a ships radio station log to the satisfaction of an attending Coast Guard Marine Inspector prior to October 17, 2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 2 October 2023
Resolution: Master provided pictures of the Radio log and enteries to prove compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 September 2023 Resolved
Each life float on a towing vessel must be in a serviceable condition and meet the functional requirements in accordance with 46 CFR 141.305(b). The life float had numerous spots with exposed flotation material and is considered in an unserviceable condition. In addition, the retro-reflective tape is worn and needs to be replaced. Either repair the life float following the manufacturers recommendations for repairs and affix new retro-reflective tape or replace the life float to the satisfaction of an attending Coast Guard Marine Inspector prior to October 7, 2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 25 October 2023
Resolution: New life float was received and was properly stowed and arranged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2023 Resolved
Each lifebuoy on a towing vessel must be fitted with retro reflective material that meets IMO Resolution A.658(16) in accordance with 46 CFR 141.360. The life ring buoy stowed on the port side bridge wing had retro-reflective tape in a poor condition and the grab line around the body of the buoy was rotted. Either replace the retro-reflective tape on each of the lifebuoys and the grab line on the port side buoy or provide new life ring buoys that are properly marked and outfitted to the satisfaction of an attending Coast Guard Marine Inspector prior to October 7, 2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 2 October 2023
Resolution: Both life ring buoys were replaced. Photographs of the new LRB's with markings, light and line were verified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 September 2023 Resolved
On each towing vessel, gauges must be installed that visually displays the RPM for each main engine and for each auxiliary generator in accordance with 46 CFR 143.230(c)(1) and (3). There was no gauge that showed RPM's in way of both the port and starboard main diesel engines and each auxiliary generator in the machinery space. Properly install an RPM gauge for all engines and demonstrate proper operation to the satisfaction of an attending Coast Guard Marine Inspector prior to October 7, 2023
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2023
Resolved 2 October 2023
Resolution: Rpm Gauges were installed in way of both auxiliary generators
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 September 2021 Resolved
The master of each towing vessel must keep an accurate list of crew members and their assigned duties and responsibilities on board in accordance with 46 CFR 140.400(a). The Master was not maintaining accurate records of the crew members in the Towing Vessel Record (TVR). Properly maintain records for all crew members and list out their assigned positions in the Towing Vessel Record. CORRECTED ON THE SPOT
Action required: 10 - Deficiency Rectified
Due 8 September 2021
Resolved 8 September 2021
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 September 2021 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The general alarm must be tested weekly and the emergency lighting system must be tested at least once every three months. The results of the tests required by this section must be recorded in the TVR. There were no records of tests for the general alarm or the emergency lighting system. Conduct all tests at the intervals prescribed in Table 143.245(b). CORRECTED ON THE SPOT
Action required: 10 - Deficiency Rectified
Due 8 September 2021
Resolved 8 September 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 August 2020 Resolved
The owner or managing operator must implement a health and safety plan in accordance with 46 CFR 140.500. There was no health and safety plan developed by the company. The plan must identify and mitigate the health and safety hazards outlined in 46 CFR 140.510 and be compiled in one single plan to the satisfaction of an attending Coast Guard Marine Inspector prior to September 24, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 16 September 2020
Resolution: Owner provided an electronic copy of the company developed Health and Safety Plan. The Health and Safety Plan provided details into the hazards outline in 46 CFR 140.510.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 August 2020 Resolved
All crew members must be provided with health and safety information and training in accordance with 46 CFR 140.515. Once the health and safety plan is developed, ensure all crew members are familiar with and have been provided training with the information in the health and safety plan and the training is documented in the company records to the satisfaction of an attending Coast Guard Marine Inspector prior to September 24, 2020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 16 September 2020
Resolution: Owner provided a copy of the training record that demonstrates all crew have been trained and are familiar with the Health and Safety Plan.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 August 2020 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing the duties expected of them during emergencies and documented in the TVR in accordance with 46 CFR 140.420. The vessel did not have any records of emergency drills and instructions in the TVR. Properly document emergency drills and crew instructions in the TVR to the satisfaction of an attending Coast Guard Marine Inspector prior to September 24, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 25 August 2020
Resolution: Master provided the required information including a brief description of the drill, participants and description of instruction upon completion of the Coast Guard witnessed drills
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 25 August 2020 Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system in accordance with 46 CFR 143.255. Provide a documented maintenance plan for all fuel systems for the main engines and generators to the satisfaction of an attending Coast Guard Marine Inspector prior to September 24, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 16 September 2020
Resolution: Owner provided a copy of the documented maintenance plan for the fuel systems.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 August 2020 Resolved
Means must be provided for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces in accordance with 46 CFR 144.605. The vents in the funnel stack had a means to secure the mechanical ventilation but did not have any closure device for the vents in the funnel. Provide a means of closing the vents in the event of an engine room fire to the satisfaction of an attending Coast Guard Marine Inspector prior to September 24, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2020
Resolved 16 September 2020
Resolution: The owner provided photographs of the closure devices for three ventilation openings for the machinery space.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 July 2019 Resolved
Update the Automatic Identification System on board the vessel to ensure the accuracy of all broadcasted dynamic, static and voyage information in accordance with 33 CFR 164.46(d). This vessel currently is transmitting an incorrect MMSI number and call sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 July 2019 Resolved
Vessels Personnel records does not keep an accurate list of crewmembers and their assigned positions and responsibilities aboard the vessel as described by 46 CFR 140.400. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 July 2019 Resolved
Vessels Emergency duties and duty stations does not include the following: Abandoning the vessel, Flooding, Launching survival craft, Heavy weather, Taking action relative to the tow, Taking action in the event of failure of propulsion, steering, or control system, Managing individuals onboard who are not crew members as described in 46CFR140.405. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 July 2019 Resolved
Vessels Emergency drills and instruction are not maintained in the TVR as described In 46CFR140.420(g). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 2 July 2019 Resolved
Vessels Fall overboard prevention procedures do not specifically address the items listed in 46CFR140.425. Produce Fall overboard prevention procedures in line with the requirements. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 2 July 2019 Resolved
Vessels navigation assessment does not itemize the items listed in 46CFR140.635 and recorded in TVR as described in 46CFR140.635(d). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 2 July 2019 Resolved
Vessel is subject to bridge to bridge requirements per 33CFR26.03(a)3 and unable to provide station logs as described by 47CFR80.409(f)(3). Ensure Radiotelephony record logs entries47CFR80.409(f)(3) paragraphs (e)(1), (3), (5) (6), (7), (10), and (11) of this section. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 July 2019 Resolved
Fire detection system does not have labels for all switches and indicator lights, identifying their functions as required by 46CFR142.330. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 July 2019 Resolved
Vessel life float is not fitted with a painter per 46CFR141.325(c). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 July 2019 Resolved
Vessel life float is not fitted with a electric water light approved under approval series 161.010. 46CFR141.325(c). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 July 2019 Resolved
Vessels Immersion suits do not have a life jacket light approved under 46CFR161.112 as required by 46CFR141.350(b) and 46CFR199.70(c)(4)(i). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 July 2019 Resolved
Vessels Immersion suits are not marked to identify the person or vessel to which it belongs as required by 46CFR141.350(b) and 46CFR199.70(c)(3). The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 July 2019 Resolved
Vessels bilge piping did not have a check/foot valve in the Cargo hold bilge suction that prevents unintended backflooding through bilge piping as required by 46CFR143.275. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 July 2019 Resolved
Vessels Electrical conductors were not watertight when passing though the aft bulkhead in upper engine room as described in 46CFR143.400. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 July 2019 Resolved
Vessel has a pinhole leak under the port watertight door coamming and does not meet the minimum requirements of 46CFR140.610. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 July 2019 Resolved
Vessels work vests storage container containing a work vest was not marked “WORK VEST” as described by 46CFR140.430(a). Mark all work vest storage containers. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2019 Resolved
Vessel fuel shut off did not indicate the purpose of the valve as described by 46CFR143.260. The vessel will be restricted from operating after August 2, 2019 if the deficiency has not been corrected to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019

Recorded names · 1

CREOLE BELLE (2008–2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.