Records from 2015 to 2026. Most recent: inspection, 4 May 2026.
Inspection history · 19
4 May 2026
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8361754
1 October 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8245015
11 December 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8035195
31 May 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7924041
19 April 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8087294
4 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7844792
6 December 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7605647
17 November 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7593815
16 February 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7397167
16 February 2022
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7397282
26 January 2022
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7386113
9 August 2021
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7281649
5 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7277619
2 April 2021
Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7168726
12 October 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7075827
4 October 2018
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6554909
7 August 2018
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6504043
3 June 2016
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5896108
30 June 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5169009
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 October 2025
Resolved
When conducting an examination of a towing vessel as required by this subpart, the surveyor must determine whether any defect, deterioration, damage, or modifications of the hull and related structure and components may adversely affect the vessel's seaworthiness or fitness or suitability for its route or service. Crop and renew weld repair on watertight bulkhead aft of port MDE at next Dry Dock Exam.
46 CFR 137.325(a)
Action required: 705 - Other - as specified
Resolved 30 June 2026
Resolution: This was rectified under activity # 7844792. An MI oversaw repair and witnessed NDT using CG-CVC Policy Letter 21-03 guidance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation. Cracked and wasted hoses on port MDE leading to expansion tank.
46 CFR 143.205(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2025
Resolved 5 November 2025
Resolution: Replaced Hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Bracket on port MDE jacket water cooling pipe not secured.
46 CFR 143.205(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2025
Resolved 5 November 2025
Resolution: Secured Bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Fuel transfer pump not secured.
46 CFR 143.205(a)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: Secured with a bolt, corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 15 October 2025
Resolved
Survival craft must be stowed in accordance with the requirements of § 199.130 of this chapter, as far as is practicable on existing towing vessels. (7) Each liferaft or group of liferafts must be arranged for float-free launching. Hydrostatic release for Life raft incorrectly attached.
46 CFR 141.130
46 CFR 199.130(c)(7)
Action required: 10 - Deficiency Rectified
Resolved 15 October 2025
Resolution: Arranged hydrostatic release to upright position on liferaft, corrected on the spot. Cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2025
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must:(1) Be maintained to ensure proper operation. Cracked and wasted hoses on STBD generator.
46 CFR 143.205(c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2025
Resolved 5 November 2025
Resolution: Replaced Hose
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 January 2024
Resolved
46CFR142.240(b) All fire-suppression and detection equipment and systems on board a towing vessel must be maintained in accordance with the attached nameplate, manufacturer's approved design manual. Fixed fire pump is leaking water when in use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2024
Resolved 26 January 2024
Resolution: Replaced fixed fire pump, now in good working order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 January 2024
Resolved
46CFR140.610(b): The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Port and STBD watertight doors leading into the engineering department have broken and degrading gaskets.
Action required: 705 - Other - as specified
Due 11 January 2024
Resolved 26 January 2024
Resolution: Replaced degrading gaskets on Port and STBD watertight doors leading into the engineering department, now in good working order.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 January 2024
Resolved
46CFR137.325(a): When conducting an examination of a towing vessel as required by this subpart, the surveyor must determine whether any defect, deterioration, damage, or modifications of the hull and related structure and components may adversely affect the vessel's seaworthiness or fitness or suitability for its route or service. STBD AFT engineering space weld seam adjacent to potable water tank is leaking water into engineering space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 26 January 2024
Resolution: Welded and NDT STBD AFT engineering space weld seam adjacent to potable water tank. No leaking observed by MI during def check.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 January 2024
Resolved
46CFR141.375(e)(1) : A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high with “DISTRESS SIGNALS”. Portable watertight container for distress signals not marked with “DISTRESS SIGNALS”. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 4 January 2024
Resolved 4 January 2024
Resolution: Portable watertight container marked with “DISTRESS SIGNALS”.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2024
Resolved
46CFR141.360(b)(4): Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel. STBD lifebuoy missing vessels name. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 4 January 2024
Resolved 4 January 2024
Resolution: STBD lifebuoy marked with vessels name.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 January 2024
Resolved
46CFR143.400(a) : Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Observed exposed dead cable center line in engineering overhead deck cable tray. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 4 January 2024
Resolved 4 January 2024
Resolution: Capped off exposed dead cable.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 November 2022
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the 33 CFR part 84 as appropriate to its area of operation. Vessel's starboard navigation light inoperable. 46CFR140.720
Action required: 10 - Deficiency Rectified
Due 18 November 2022
Resolved 18 November 2022
Resolution: Corrected on the spot
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 November 2022
Resolved
Emergency lighting must be provided for all internal crew working and living area. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Automatic, battery-operated with a duration of no less than 2 hours. Vessel's emergency lighting was insufficient. Replace battery pack. 46CFR140.715(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 6 December 2022
Resolution: Vessel replaced battery with larger batter and charger. Witnessed emergency lights.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 November 2022
Resolved
The VHF-FM radio must be installed at each operating station and connected to a functioning battery backup. Vessel's secondary power source is insufficient. Replace battery pack. Vessel is restricted to daylight operations. 46CFR143.555(a)(3)
Action required: 705 - Other - as specified
Due 24 November 2022
Resolved 6 December 2022
Resolution: Vessel replaced battery with larger battery and charger. Witnessed Captain conduct a successful radio check.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 17 November 2022
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. Fresh water tank has pinhole leak penetrating aft bulkhead of ER, stbd side at weld seam. Submit repair plan. 46CFR143.270
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 6 December 2022
Resolution: Vessel did not submit a repair plan. Instead, they grinded down to good metal and rewelded on from and back of bulkhead. Completed hydro NDT. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 November 2022
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, in the machinery space. Fuel transfer pump in ER is leaking diesel fuel, and requires repair. 46CFR143.220(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2022
Resolved 6 December 2022
Resolution: Witnessed operation of fuel transfer pump with no leaks observed. All sat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 18 October 2021
Resolved
If the cognizant OCMI has reasonable cause to believe that a vessel's survey program is deficient; that OCMI may require an audit or survey of the vessel in the presence of a representative of the cognizant OCMI, increase the frequency of the audits, or require any other specific action within his/her authority that he/she considers appropriate. Due to the number of deficiencies discovered and lack of objective evidence, the vessel is required to undergo an external vessel survey completed by the TPO in the presence of Coast Guard.
46CFR137.212
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 January 2022
Resolution: MI's attended vessel survey on 2Oct21, Sabine provided copy of findings report 06Jan22
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 18 October 2021
Resolved
If the cognizant OCMI has reasonable cause to believe that a vessel's survey program is deficient; that OCMI may require an audit or survey of the vessel in the presence of a representative of the cognizant OCMI, increase the frequency of the audits, or require any other specific action within his/her authority that he/she considers appropriate. Due to the number of deficiencies discovered and lack of objective evidence, the vessel is required to undergo an external vessel audit completed by the TPO in the presence of the Coast Guard.
46CFR137.212
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 January 2022
Resolution: MI's attended vessel audit on 03Oct21, Sabine provided copy of findings report 06Jan22
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2021
Resolved 16 November 2021
Resolution: Temp COI issued by Sec VA.