Records from 2016 to 2026. Most recent: inspection, 8 February 2026.
Inspection history · 54
8 February 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8307634
10 December 2025
MSP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8233460
27 November 2025
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8274661
23 February 2025
Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8083198
16 February 2025
Deficiency Check · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8080182
16 February 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8080286
15 February 2025
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8080034
22 January 2025
Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8066751
13 January 2025
Deficiency Check · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8063618
10 January 2025
Explosive Handling Operation-Commercial · Explosive Handling Operation-Military
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8073655
3 December 2024
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8042888
29 November 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8042072
30 October 2024
Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8027304
22 October 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8023974
13 August 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7980987
29 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7932397
29 March 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7887165
27 March 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7886421
9 March 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7876401
4 March 2024
Type not recorded
No type recorded · Activities Europe · Activity 7892840
22 February 2024
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7869346
19 February 2024
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7867267
9 February 2024
Administrative Inspection
Administrative · Activities Europe · Activity 7864744
7 December 2023
COI Inspection · MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Activities Europe · Activity 7820654
31 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Activities Europe · Activity 7817924
2 August 2023
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7758927
19 June 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7718735
17 May 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7691188
12 April 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7670033
7 March 2023
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7646817
22 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7640104
31 January 2023
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7637568
28 December 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7613755
27 December 2022
Annual Inspection · MSP Annual Oversight
Physical examination · Activities Europe · Activity 7613190
30 November 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7601808
19 October 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7581094
18 October 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7579964
2 August 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7522855
7 July 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500095
23 June 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7485756
22 May 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7457191
14 April 2022
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7431319
13 April 2022
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7430269
2 February 2022
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7413076
18 November 2021
Explosive Handling Operation-Military
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7355580
1 October 2021
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7324855
15 September 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7313098
29 August 2021
Explosive Handling Operation-Commercial
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7300419
23 July 2021
Explosive Handling Operation-Military
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7268391
23 June 2021
Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7233634
14 May 2021
MSP Initial Reflag · Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7221588
7 May 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7191506
6 May 2021
MARPOL Annex VI Survey · Ballast Water Examination · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7190561
9 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5794269
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Provide tech report to Coast Guard showing satisfactory operation of #1 and #3 start air compressors.
74SOLAS(20 Con)I/11(a)
Action required: 705 - Other - as specified
Due 29 December 2024
Resolved 14 January 2025
Resolution: 31DEC24: Extended at request of o/o to be due 08JAN25. 14Jan25 recieved report confirming operation of the air compressors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2024
Resolved
Each Captain of the Port may order a vessel to operate in the manner directed when the Captain of the Port has determined that such order is justified in the interest of safety by reason of weather, visibility, sea conditions, temporary port congestions, other temporary hazards circumstances, or the condition of the vessel.
While transiting to through the Sector Virginia regulated navigation area (RNA), as defined by Title 33, Code of Federal Regulation (CFR), 165.501 (a)(2): your vessel shall be escorted by either:
- One tug of not less than 3,000 horsepower and one tug of not less than 2,000 horsepower, or;
- Two tugs of not less than 50 Ton Aggregate Bollard Pull, or;
- One tug of not less than 50 Ton Bollard Pull.
33 CFR 160.111(c), 705c
Action required: 705 - Other - as specified
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The main L/O manual by-pass filter valve, although closed is actively leaking oil into the bilge.
74SOLAS(20 Con)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2024
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The central F.W. cooler temp control valve is actively leaking cooling water into the bilge.
74SOLAS(20 Con)I/11(a)
This deficiency originally issued code 17c, down graded to 705c and due NLT 29DEC24. See explanation in narrative.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2024
Resolved 15 January 2025
Resolution: Vessel Capt provided FAR from Lloyds crediting the repair and satisfaction to class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #3 SSDG is missing pipe lagging in the vicinity of the turbo. 705 c: Due in 7 days.
74SOLAS(20 Con) I/11(a)
Action required: 705 - Other - as specified
Due 11 December 2024
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 December 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. A smoke detector in the purifier room above the #2 purifier is being secured to its base with black electrical tape.
SOLAS (20 Con) II-2/14.2.1.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 December 2024
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #1 G/E lube oil booster pump in the purifier room is missing it's guard for the motor shaft flange coupling.
74SOLAS(20 Con)I/11(a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #2 G/E F/O heater in the purifier room is actively leaking fuel into a bucket which is located on the deck under piping. The heater pipe flange located under the leak is missing its lagging. The fuel leak appears to have saturated the surrounding piping lagging.
74SOLAS(20 Con)II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 31 December 2024
Resolution: Cleared on the basis of receipt and review of satisfactory class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The M/E leak off alarm pipe lagging is not properly secured on three pipes at the engine free end.
74SOLAS(20 Con)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2025
Resolved 15 January 2025
Resolution: 31DEC24: Extended at request of o/o to be due 08JAN25. Outstanding condition of class addressing lagging condition in general was also extended to 15JAN25. M/E leak off pipin properly lagged.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Some of the steam pipe lagging for the hot water heater is missing, and some destroyed.
74SOLAS(20 Con)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The oily bilge pumping system was modified, to include the addition of new piping, flanges, an air operated pump, and a cross connect to the sludge system. No approved plans were available to support the modifications.
74SOLAS(20 Con)I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2025
Resolved 15 January 2025
Resolution: 31DEC24: Sytem was restored to condition in original plans. Once LR approves the new plans, the updates will be reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 4 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. A saltwater pipe for the CHT system in the overhead of the purifier room above the #2 purifier is wasted.
74SOLAS(20 Con)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 31 December 2024
Resolution: Cleared on the basis of receipt and review of satisfactory class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Two of the three start air compressors are inoperable.
74SOLAS(20 Con)I/11(a)
74SOLAS(20 CONS) I / 11 c
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 8 December 2024
Resolution: Received survey report attesting to repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 30 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Vessel has an approximately 2 inch long crack, approximately 2 feet above the waterline, in the #4 starboard ballast tank.
74 SOLAS (20) 1/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2024
Resolved 16 January 2025
Resolution: Hull repair conducted in Charleston and confirmed by LR and evidenced by annual endorsement of Load Line cert and Safety Contruction Cert.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 11 December 2023
Resolved
The launching mechanism shall be so arranged that it may be actuated by one person from a position on the ship's deck and, except for secondary launching appliances for free-fall lifeboats, from a position within the survival craft or rescue boat. While lowering the port lifeboat, the crew utilized the davit remote control wire inside the lifeboat. The remote control stopped approximately 15-20 feet above the water which prevented the crew to lower the lifeboat to the water. Due to the vessel’s mooring condition, USCG was unable to verify operation of stbd lifeboat's davit remote control.
Cite: SOLAS III/Reg 16.1 LSA Code 6.1.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 December 2023
Resolution: Emails from LR indidicate deficiency was addressed by LR from issuance of certificates on 16Dec2023. No finding number was provided. 29Dec2023: emailed LR directly to ensure this was witnessed/verified by same.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 December 2023
Resolved
Posters or signs shall be provided on or in the vicinity of survival craft and their launching controls shall be easily seen under emergency lighting conditions Launching instructions for liferafts were not posted under an emergency light.
Cite: SOLAS (2009) III/Reg 9.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 21 February 2024
Resolution: Reviewed FSR Report 2219867, Version 1. Launching procedures were posted and witnessed by LR surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2023
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Identified the following improper electrical installations:
• Improper electrical connection (hole drilled in outlet and wire run through it with daisy chain to radio charger).
• Improper electrical connection and wiring to stbd light for accommodation ladder.
• 02 light diffusers were cracked in EDG room.
Cite: SOLAS (2009) II-1/Reg 40.1.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 21 February 2024
Resolution: Reviewed FSR Report 2219867, Version 1. Electrical installations were rectified by LR surveyor.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 December 2023
Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seaman serves, and the MMC, along with a valid medical certificate, must be presented to the master of the vessel at the time of employment or before signing Articles of Agreement. Two crew members were missing medical waivers, as required by the medical certificate and the medical waiver.
Cite: 46 CFR 15.401(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2024
Resolved 5 March 2024
Resolution: Master provided statement that crew members departed vessel and all crew members on board had medical certs and medical waivers (as necessary).
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 December 2023
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting division, and protection of openings and penetrations in these divisions. Two self-closing fire doors were found propped open: (1) the A-0 self-closing door from accommodations to the wheelhouse; (2) the A-0 self-closing door to the steering gear room.
Cite: SOLAS II-2/Reg 14.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Corrected during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 11 December 2023
Resolved
Periodic safety test must be conducted at periodic intervals specified by the Coast Guard to confirm vital systems and safety features continue to operate in safe, reliable manner. The PSTPs were missing the approval letter, The crew was testing to an unapproved revision, and the crew was unfamiliar with properly recording the PSTPs to ensure annual completion.
Cite: 46 CFR 61.40-6(b)
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Crew provided supporting documentation.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 December 2023
Resolved
The Oil Record Book (ORB) Part I shall be completed on each occasion, on a tank by tank basis if appropriate, whenever any of the following machinery space operations take place in the ship: Collection and disposal of oil residues. There were no ORB entries for weekly soundings completed from 10 Nov 2023 through 08 Dec 2023. The Chief Engineer reported he did not make entries due to tank cleaning while in drydock.
Cite: MARPOL Annex I/Reg 17 and Appendix III
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: The chief engineer updated the ORB.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 11 December 2023
Resolved
Except as provided by 15.725 of this part (sailing short), no vessel may be navigated unless it has in its service and onboard the crew complement required by the COI. Two Able Seamen (or 2 Ordinary Seaman with RFPNW) were missing from the provide crew list/COI required crew complement.
Cite: 46 CFR 15.515(a)
Action required: 10 - Deficiency Rectified
Resolved 11 December 2023
Resolution: Two ABs reported on board to fill MSM.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 7 December 2023
Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with national and international requirements. During a USCG Certificate of Inspection, the ship was missing two Able Seaman from its crew compliment. Also, two crewmembers did not have their medical waivers on board, as required by the medical certificate and medical waiver. Reviewed the SMS Form “Sign-On and Sign-Off Form” and noted no pre-screening or reference to medical waivers, only medications. Conduct an internal safety audit and corrective action of the hiring/manning process within the Safety Management System.
Action 705: Due 11Mar2024.
Cite: SOLAS (2009) IX/Reg 3.1, ISM Code Part A 6.2.1
Action required: 705 - Other - as specified
Due 11 March 2024
Resolved 2 April 2024
Resolution: 11Mar24: Extended CG-835 due to ACTEUR comms between LR and CVC on def. 18Mar24: CG-835 extended to 29Mar24 so LR can issue PR-17 to ABS. 29Mar24: Extended def. No further response from LR or ABS acceptance. 02Apr24: LR confirmed ABS PR-17 acceptance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2023
Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply
with the following: in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. All alarms were not relaying to the bridge for any of the pumps. Rectify issue prior to sailing from next foreign port (Hamburg, Germany 18JAN23).
Action required: 15 - Rectify deficiencies by next port
Due 18 January 2023
Resolved 18 January 2023
Resolution: Rcvd tech report attesting to proper operation of alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 27 December 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working
order and ready for immediate use. Port and starboard lifeboats both had large indents on both sides of each hull. Provide acceptable proof that both lifeboats are fit for service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2023
Resolved 18 January 2023
Resolution: Rcvd tech report attesting to safety of lifeboats, no visual cracks noted.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 30 November 2022
Resolved
Engines installed on vessels that were constructed on or after January 1, 2000, with power output of more than 130 kW must be covered by a valid EIAPP certificate, certifying the engine meets the applicable emission standards of Annex MARPOL Annex VI. Provide EIAPP Certificates for all applicable marine diesel engines as proof of emissions compliance with the IAPP. 40 CFR 1043.30
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 15 November 2023
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 14 April 2022
Resolved
All ships of 300 gross tonnage and upwards shall be fitted with an echo sounding device, or other electronic means, to measure and dispay the available depth of water. Vessel's echo sounding device is currently inoperable. Prove proper operations of echo sounding device prior to departure for Savannah, GA.
74 SOLAS Cons (2020) V/19.2.3.1
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: Recieved work order from vessel Captain verifying that the echo sounder has been repaired by McKay Marine is now operational. Because parts were unavailable in the US, a new JFE-680 200 khz unit was installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 21 June 2021
Resolved
Engines installed on vessels that were constructed on or after January 1, 2000, with power output of more than 130 kW must be covered by a valid EIAPP certificate, certifying the engine meets the applicable emission standards of Annex MARPOL Annex VI. Provide EIAPP Certificates for all applicable marine diesel engines as proof of emissions compliance with the IAPP. 40 CFR 1043.30
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 30 June 2021
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 14 May 2021
Resolved
In a space described in 113.25-9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red flashing light or rotating beacon, in addition to the general emergency alarm signal. General alarm lights are not working in the bosun's stores or bow thruster space. Vessel submitted risk mitigation plan to decrease personnel access to affected spaces during routine operations.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 30 June 2021