Records from 2014 to 2025. Most recent: inspection, 8 September 2025.
Documentation record
Registered dimensions (L × B × D)297.6 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNASHVILLE, TN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton
1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
8 September 2025
Drydock Exam · Cargo Tank Internal · Examination of Repairs · COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8214521
17 June 2025
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8156356
2 July 2024
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7947483
13 June 2023
Periodic Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7714344
19 May 2022
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7451958
24 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7417989
30 April 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7185914
22 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7182838
5 April 2021
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7168883
9 September 2020
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7062018
10 July 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7101657
9 December 2019
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6877142
24 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6840936
18 December 2018
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6599148
27 February 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6362299
20 February 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6358007
14 December 2017
Periodic Inspection · Deficiency Check · Administrative Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6324241
4 December 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6317887
16 August 2017
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6244734
17 October 2016
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6024236
27 September 2016
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6012792
21 September 2016
Damage Survey
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6006173
20 September 2016
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6006874
17 November 2014
Construction Oversight · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5214282
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 June 2023
Resolved
Scantlings, material, and workmanship, subdivision of
cargo spaces, fitting of cofferdams, and testing of
tanks shall be at least equivalent to the requirements
of the American Bureau of Shipping or other recognized
classification society.
Marine Inspector observed 1 inch sized hole along seam
on starboard corner of bow headlog.
Enact repairs to vessel prior to carriage of cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2023
Resolved 19 July 2023
Resolution: Marine Inspector observed satisfactory repairs per attached plate summary.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2021
Resolved
For vessels with a square bow, the name and hailing port must be marked on some clearly visible exterior part of the stern. Vessel had incorrect and unpainted hailing port.
46 CFR 67.123(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 May 2021
Resolved 30 April 2021
Resolution: Vessel rep sent picture of corrected Hailing Port
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 18 December 2017
Resolved
Each cargo tank must be equipped with high level alarm and tank overfill alarm that is able to be verified for proper operation prior to each transfer. Alarms inoperable when tested. Control Panel displayed High humidity code. 46 cfr 39.2009
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2017
Resolution: Vessel Rep had a repair technician troubleshoot and repair the Control Panel. Control Panel Repairs complete New Battery installed. Tested system. Passed operational test.
Documentation › Certificates/Documents › Permit, Other
Issued 18 December 2017
Resolved
Vessel that operates in fresh water at least six months in every 12 month period will be inspected IAW 31.10-21 (b). Fresh water exemption letter needs to be updated to operate in Corpus Christi AOR.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 20 February 2018
Resolution: Documentation was received identifying Fresh water operations meeting Fresh water Criteria.
Deck/Cargo › Cargo Stowage › General
Issued 17 October 2016
Resolved
Each cargo tank of a tank barge must have one of the following liquid protection arrangements:
Barge Cargo Tank High Level and Overfill protection alarm system not properly operating. Power Failure Alarm Indication and Overflow Control System Inop.
Prove Proper Operation in pressence of USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 November 2016
Resolved 18 October 2016
Resolution: Barge Rep [name withheld] to notify 835 work has be completed and requested MI to clear the 835. All repairs complete cleared 835.
Construction/Loadline › Hull › Hull Plating
Issued 21 September 2016
Resolved
Barge involved in collision experiencing significant damage to port bow. Barge to transit to Ingleside, TX to effect permanent repairs at Bloodworth prior to taking cargo. Contact local OCMI upon arrival.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 October 2016
Resolution: All Damage to Rack and Stern Box are complete. Tested satisfactory. Visual with soap and 2 psi on tank's.