MAURY USCG vessel records
← All vessels

MSC PETRA

MSC PETRA is a 2001 freight ship. The Coast Guard has recorded 35 inspections since 2018, most recently in February 2026, along with 27 deficiencies and 12 operational controls, 2 with no removal date recorded.

Records from 2018 to 2026. Most recent: inspection, 9 February 2026.

Built
2001
Last inspected
9 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
2 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 February 2026
…with no type recorded14
Operational controls 2 with no removal date recorded
Years with a record 6 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9222302
1323185
Flag
LIBERIA
Maury page id
psix-1323185

Documentation record

Tonnage as PSIX records it80238 - Dead Weight, Metric Ton
107027 - Displacement, Metric Ton
73157 - Convention (Subpart B), Gross Ton
41255 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DIANE MORAN Towing Vessel · MISLE 29710 · 4 September 2023 · activity 7785910ELIZABETH TURECAMO Towing Vessel · MISLE 475797 · 4 September 2023 · activity 7785910

Inspection history · 35

9 February 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8307926
9 December 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8282081
18 October 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8254942
19 August 2025 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8213228
3 March 2025 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8087177
29 November 2024 PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8041265
19 November 2024 PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8036819
9 September 2024 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7999750
7 September 2024 PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7991935
30 May 2024 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7921646
21 May 2024 PSC B · In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7916164
26 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7870266
23 February 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7867779
23 February 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7869649
18 February 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7866957
16 February 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7866511
10 February 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7863648
9 February 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7863586
6 December 2023 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7834585
23 November 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7828923
11 September 2023 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7786829
5 September 2023 PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7784789
4 September 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7785910
30 August 2023 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7780907
28 August 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7778335
23 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7775342
21 August 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773083
18 August 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7771422
31 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7701594
22 May 2023 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7694123
26 January 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7625109
19 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6815594
18 September 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6815128
4 December 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6591869
28 September 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6550789

Deficiency record · 27

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 September 2024 Resolved
In a ship in which oil fuel is used, the arrangements for storage, distribution, and utilization of oil fuel shall be such as to ensure the safety of the ship . DG #1, while not energized was observed to be excessively leaking fuel from filters. 74SOLAS (01 con) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 8 September 2024
Resolved 9 September 2024
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 September 2024 Resolved
Access doors normally closed at sea intended to ensure watertight integrity shall be provided with means of indicating locally & on the bridge. FWD port & stbd watertight doors on both tunnels were observed to have there indicators tied to indicated "closed" while doors remained open. 74SOLAS (04 con) II-1/25.9.3
Action required: 10 - Deficiency Rectified
Resolved 7 September 2024
Resolution: Crew remove both tie backs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 May 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementation of the ISM Code. An external audit report satisfactory to the COTP must be submitted prior to the clearance of this deficiency. 74 SOLAS (20) IX/3.1 ISM Code 10.1
Condition: Invalid
Action required: 30 - Ship detained
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 May 2024 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be as such to ensure the safety of the ship and persons on board. PSCO observed evidence of oil leakage from the space above the purifier room, which includes auxiliary engine #3. 74 SOLAS (2001 CONS) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 May 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed water accumulation around switchboards in both port and starboard emergency escape routes from the engine room. 74 SOLAS (04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 21 May 2024 Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed steam line leaks in both port and starboard emergency escape routes from the engine room. 74 SOLAS (04) II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 21 May 2024 Resolved
Every ship... shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for minimizing, collecting, storing, processing and disposing of garbage, including the use of equipment on board. PSCO observed excessive garbage accumulation throughout the engine room. MARPOL ANNEX V/10.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 May 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed freshwater line leak in purifier space. 74 SOLAS (20) I/11a 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 May 2024 Resolved
Electrical installations shall be such that: electrical services essential for safety will be ensured under various emergency conditions. PSCO observed 34 inoperable lights in the engine room, CO2 room, and both port and starboard emergency escape routes from the engine room. 74 SOLAS (04) II-1/40.1.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Please see Narrative to see resolution of deficiency.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 6 December 2023 Resolved
Under all sailing conditions, including manouvering, the speed, direction of thrust and, if applicable, the pitch of the propeller shall be fully controllable from the navigation bridge. Vessel reported that the remote control for the main engine was inoperable. 74 SOLAS (04) II-1/49.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2024
Resolved 23 May 2024
Resolution: Please see Narrative for clearing of deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 5 September 2023 Resolved
After any survey of the ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements, or material covered by the survey without the sanction of the Administration except the direct replacement of such equipment and fittings. PSC Officer observed oil content meter MEPC 107 installed on oily water separator. IOPP supplement Form A requires installation of MEPC 60. MARPOL 1/6.4.2 (17AC)
Action required: 17 - Rectify deficiencies prior to departure
Due 14 September 2023
Resolved 11 September 2023
Resolution: Cleared by classification society.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2023 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restricted even though one of the essential auxiliaries becomes inoperable. Special consideration shall be given to the malfunctioning of an air compressor and receiver for starting or control purposes. PSC Officer observed failed concentric valve on #1 air compressor. SOLAS(2020) II-1/26.3.9 (17AC)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 September 2023
Resolution: Received class report, confirming air compress was tested and found satisfactory.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 September 2023 Resolved
The oil record book Part 1 shall be completed whenever any of the following operations takes place in the ship: Discharge overboard of bilge water accumulated in machinery space. PSC Officer observed on 10AUG2023 ORB entry for overboard discharge did not match records found in MEPC 107 oil content meter. MARPOL1/17.2.4 (10C)
Action required: 10 - Deficiency Rectified
Resolved 5 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 September 2023 Resolved
Fire doors in main vertical zone bulkheads shall satisfy the following requirements: The doors shall be self-closing. PSC Officer observed inoperable self-closing door for upper deck duct trunk. SOLAS (2020) II-2/30.4.1 (10C)
Action required: 10 - Deficiency Rectified
Resolved 5 September 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 5 September 2023 Resolved
In calendar year 2023, the ship has received 5 Port State control exams I the United States (Charleston, New York, Virginia, Baltimore, Charleston). The technical and operational deficiencies recorded during the exams indicate a lack of effectiveness of the ISM Code. This ship is directed to complete an audit and implement corrective actions within 3 months. SOLAS (2020) IX/3.1 ISM CODE1.2 (50A)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2023
Resolved 23 November 2023
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 August 2023 Resolved
The arrangements for the utilization of flammable oils employed under pressure in power transmission systems shall be such as to ensure the safety of the ship and persons onboard. PSCO observed high pressure fuel oil leak on cylinder number two fuel pump of the number 3 generator. 74SOLAS(01)II-2/16.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2023
Resolution: Received class report attesting to repairs made by the crew rectifying the fuel pump leak on the number two cylinder of generator number three.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023 Resolved
All electrical apparatus shall be so installed as to not to cause injury when handled or touched in the normal manner. PSCO observed wires leading to previously installed motor controller that were taped up arcing and smoking when handled. At installed foam tank. 74SOLAS(04)II-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2023
Resolution: Received class report attesting that exposed wiring was properly isolated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 August 2023 Resolved
Boilers shall be provided with means to supervise and control the quality of the feedwater. Suitable arrangements shall be provided to preclude the entry of oil which may affect the boiler. PSCO observed "high oil level in feed water" indicator lit at the boiler alarm panel. 74SOLAS(04)II-1/32.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 11 September 2023
Resolution: Cleared by classification society.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 August 2023 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. PSCO observed expired inspection labels and no service record was able to be provided by the crew. 74SOLAS(20)II-2/14.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 11 September 2023
Resolution: Cleared by classification society.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023 Resolved
All electrical apparatus shall be so installed as to not to cause injury when handled or touched in the normal manner. PSCO observed multiple exposed wires during the engine room exam at seachest, exhaust gas scrubber automatic actuating valve, pump room, main engine junction box number three, pump motor by sea chest. 74SOLAS(04)II-1/45.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 11 September 2023
Resolution: Cleared by classification society.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 August 2023 Resolved
Where "A" class divisions are penetrated such penetrations shall be tested in accordance with the fire test procedures code. Such penetrations shall be suitably insulated by extension of the insulation at the same level of the division. PSCO observed approved sealant used for repair. 74SOLAS(20)II-2/9.3.3.1
Action required: 10 - Deficiency Rectified
Resolved 28 August 2023
Resolution: PSCO observed approved sealant used for repair
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 August 2023 Resolved
EFFICIENT GUARD RAILS OR BULLWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. MULTIPLE CONSECUTIVE PORT-SIDE RAILINGS WERE DISCOVERED TO BE SEVERLY BENT, CONSTITUTING A HAZARD TO CREW SAFETY.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 5 September 2023
Resolution: Class report received attesting to repairs to the railing onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 August 2023 Resolved
MAIN AND AUXILIARY MACHINERY ESSENTIAL FOR THE PROPULSION AND SAFETY OF THE SHIP SHALL BE PROVIDED WITH EFFECTIVE MEANS FOR ITS OPERATION AND CONTROL. VESSEL UNABLE TO CONTROL PROPULSION OF MAIN ENGINE VIA REMOTE CONTROL FROM BRIDGE.
Action required: 60 - Rectify deficiencies prior to movement
Due 21 August 2023
Resolved 27 August 2023
Resolution: Vessel submitted a class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 August 2023 Resolved
ANY REQUIRED FIXEDC FIRE DETECTION AND FIRE ALARM SYSTEM WITH MANUALLY OPERATED CALL POINTS OF IMMEDIATE OPERATION AT ALL TIMES. FIRE DETECTION SYSTEM FOR CARGO HOLDS EXPERIENCING ERRORS THAT IMPEDE EFFECTIVE OPERATION.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2023
Resolved 5 September 2023
Resolution: Vessel submitted a class report attesting to repairs. Vessel was given 14 days to rectify and allowed to leave the port. UPDATE: New class report submitted. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 4 December 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Marine Inspector found gel coat to be damaged on STBD side Rescue Boat. 74SOLAS(14)III/20.2 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2018
Resolved 19 September 2019
Resolution: Received, reviewed and accepted proper documentation from vessels Master verified by vessels class society, stating the deficiency was rectified. Crew cleaned rescue boat with fresh water and applied 02 coats of Gel Coat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 December 2018 Resolved
All electrical apparatus shall be constructed and so installed as not to cause injury when handled or touched in the normal manner. Marine Inspector found electrical stuffing tubes to be wasetful out on deck. 74SOLAS(04)II-1/45.1.3 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2018
Resolved 19 September 2019
Resolution: Received, reviewed and accepted class report of proper documentation from the vessels Master verified by vessels class society, stating the deficiency was rectified. Crew cropped & renewed wasted electrical componets, painted and operation test conducted.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Marine Inspector found lashing bridge supports wasted throughout vessel on deck. 74SOLAS(14)I-11(a) 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2018
Resolved 19 September 2019
Resolution: Received, reviewed and accepted class report of proper documentation from the vessels Master verified by vessels class society, stating the deficiency was rectified. Crew cropped & renewed wasted collapsible railings throughout the ship, applied paint.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.