MAURY USCG vessel records
← All vessels

ROBIN MARIE

ROBIN MARIE is a 2016 towing vessel. The Coast Guard has recorded 33 inspections since 2016, most recently in February 2026, along with 41 deficiencies, 3 operational controls and 6 casualty investigations between 2016 and 2024.

Records from 2016 to 2026. Most recent: inspection, 4 February 2026.

Built
2016
Last inspected
4 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 4 February 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9753181
WDM6343
1323239
Flag
UNITED STATES
Maury page id
psix-1323239

Documentation record

Registered dimensions (L × B × D)142.6 ft × 50.0 ft × 28.7 ft
Registered tonnagegross 299 / net 203
ITC dimensions (L × B × D)142.6 ft × 50.0 ft × 28.7 ft
ITC tonnagegross 1,763 / net 528
BuilderVT HALTER MARINE INC · ESCATAWPA, MS, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 30 September 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it528 - Convention (Subpart B), Net Ton
203 - Regulatory (Subpart C or D), Net Ton
1763 - Convention (Subpart B), Gross Ton
299 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

Inspection history · 33

4 February 2026 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8305817
20 January 2026 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8297393
3 December 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8022904
18 June 2024 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7937718
3 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7925974
2 June 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7941114
17 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7914073
12 May 2024 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7911181
12 May 2024 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7911655
8 February 2024 TPO Audit
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7885380
6 February 2024 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7856290
2 December 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7832570
12 September 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7790183
11 September 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7795575
29 June 2023 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7726320
5 April 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7663405
12 December 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7608675
12 September 2022 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7557316
23 November 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7359364
20 July 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7010986
9 May 2020 COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6950716
3 April 2020 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6936164
2 March 2020 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6919278
6 February 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6904303
10 August 2019 Deficiency Check · In-Service Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6778503
29 April 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6673043
28 February 2019 Administrative Inspection · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6639939
22 June 2018 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6512942
17 August 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5975235
22 March 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5838239
22 March 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5864220
4 March 2016 MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5825670
4 March 2016 Industry Initiated Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5827339

Deficiency record · 41

05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 20 January 2026 Resolved
(a) Each towing vessel operating on oceans, coastwise, limited coastwise, or beyond 3 nautical miles from shore upon the Great Lakes must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon (EPIRB) that meets the requirements of 47 CFR part 80. (b) When the towing vessel is underway, the EPIRB must be stowed in its float-free bracket with the controls set for automatic activation and be mounted in a manner so that it will float free if the towing vessel sinks. The EPIRB's hydrostatic release was not marked with an expiration date and the installation date was not known. Install a new hydrostatic release and ensure the appropriate expiration date is appropriately marked on it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2026
Resolved 4 February 2026
Resolution: New hydro release with appropriate date of expiry marked on it has been installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2024 Resolved
46 CFR 143.205(a) Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed exhaust leaks on both MDE near the turbos.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 10 December 2024
Resolution: Repaired exhaust and lagging, conducted MDE test up to 900RPM.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 3 December 2024 Resolved
46 CFR 143.205(b) The crew of each towing vessel must demonstrate the ability to operate the primary and auxiliary machinery and electrical systems for which they are responsible, and to do so under normal and emergency conditions. MI observed that the crew was unable to test the emergency lighting due to an inoperable breaker.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 10 December 2024
Resolution: Conducted Emergency generator test with darken ship, inspected all emergency lighting was energized on Emergency Generator Power.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 December 2024 Resolved
46 CFR 144.320(b) Closure devices must be provided for deck house or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. MI observed port aft and starboard aft watertight closures with worn seals resulting in water intrusion when tested with firehouse. Closure devices require watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 10 December 2024
Resolution: Conducted fireman hose test on both port and stbd aft watertight enclosures with no protrusion of water below decks.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 3 December 2024 Resolved
46 CFR 137.320 A drydock and internal structural examination performed for a towing vessel to maintain a valid load line certificate issued in accordance with subchapter E of this chapter would count as an examination required under § 137.300. Vessel was unable to provide proof that vessel was dry docked during last load line survey.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 5 December 2024
Resolution: Provided clarification on LL certificate and UWILD enrollment for dry dock haul out. [name withheld] confirmed acknowledgement of UWILD enrollment at next dry dock.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 December 2024 Resolved
46 CFR 142.240 All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months. MI observed that the semi-portable extinguisher aft of the stbd MDE did not have a servicing tag.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 10 December 2024
Resolution: Semi-portable was servied, and had associated paperwork.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 December 2024 Resolved
46 CFR 136.212(b) The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable statutes and regulations for such vessels. The inspection will include inspections of the structure, pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire detecting and extinguishing equipment, pilot boarding equipment, and other equipment MI observed 02 A-60 doors that did not latch.
Action required: 10 - Deficiency Rectified
Due 3 December 2024
Resolved 3 December 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 December 2024 Resolved
46 CFR 136.212(b) The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended, and that it complies with the applicable statutes and regulations for such vessels. The inspection will include inspections of the structure, pressure vessels and their appurtenances, piping, main and auxiliary machinery, electrical installations, lifesaving appliances, fire detecting and extinguishing equipment, pilot boarding equipment, and other equipment. MI observed multiple areas on the 01 deck that need further gauging. Provide gauging report.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2024
Resolved 10 December 2024
Resolution: Inspected clad welding on 01 deck.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 3 December 2024 Resolved
46 CFR 142.325 All suction valves necessary for the operation of the fire main must be kept in the open position or capable of operation from the same place where the remote fire pump control is located. MI observed that the check valve on the main fire pump was malfunctioning.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 10 December 2024
Resolution: Observed new check valve installed on fireman.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 December 2024 Resolved
46 CFR 144.605 Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. MI observed that the port MDE damper was inoperable.
Action required: 10 - Deficiency Rectified
Due 3 December 2024
Resolved 3 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2024 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. SME turbo failed preventing proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2024 Resolved
Propulsion machinery must be maintained to ensure proper operation. Vessel experienced a loss of port propulsion engine while towing due to a failed turbo charger. Repair to the satisfaction of the Coast Guard. 46 CFR 143.205
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2024
Resolved 12 June 2024
Resolution: Engine repairs have been made and operational tests were SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 December 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel experienced control issue on port engine. 46 CFR 143.205(c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2023
Resolved 2 December 2023
Resolution: ABS attended vessel and confirmed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 September 2023 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel reported a loss of oil pressure on their reduction gear which resulted in a loss of propulsion on their starboard engine. Provide a technical report attesting to proper operation of the vessel. 46 CFR 143.205(c)(1) - 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2023
Resolution: Attended vessel to witness operation of the stbd engine and satisfactory reduction gear oil pressure. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 February 2021 Resolved
The owner and managine operator must ensure that the towing vessel is in compliance with this subchapter and other applicable laws and regulations at all times. This vessel is subject to a 5 year interval for dry dock, which expires february 13, 2021. Conduct a dry dock examination to the satisfaction of a CG marine Inspector prior to conducting any cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2021
Resolution: Conducted Satisfactory DD
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 May 2020 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The rescue boat davit system had a jumper wire for the limit switch. The 02 life rafts on board were improperly installed with the painter line attached to the vessel and not weak link. Life rafts were corrected on the spot. Rescue boat davit limit switch must be properly fixed for proper operation and fall service to be completed. Prior to departure into the gulf from LMR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2021
Resolution: Liferafts onboard were properly installed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2020 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: Crew state rooms did not have lights or phosphorescent adhesive lighting strips that are installed that are sufficiently visible to enable egress with no power. Galley and mess room had no emergency lighting or adhesive lighting strips. Provide proper lighting or adhesive lighting strips. Prior to departure into the gulf from LMR.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2021
Resolution: Verified E-lighting in the galley
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2020 Resolved
A towing vessel must carry adequate and up to date charts, maps and nautical publications for the intended voyage, US Coast Pilot [name withheld] list and other publications. Spoke to the Chief Mate after reviewing charts, Coast Pilot and determined they made the voyage from Port Sulphur to New Orleans with uncorrected charts, Coast pilot and Light List. Make all updates to current local charts, obtain charts for next destination and current publications. Prior to departure into the gulf from LMR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Updated charts with corrections and all electronic correspondance are available.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 11 May 2020 Resolved
The officer in charge of a navigational watch must conduct a navigation assessment for the intended route and operating prior to getting underway. The navigation assessment must incorporate the requirements of pilothouse resource management of 140.640 assess operational risks and anticipate and manage workload demands. Crew did not have knowledge and the difference between a voyage plan versus a navigation assessment and the requirement of updating of changes to navigation assessments. Provide proper training on the difference between voyage plan and navigation assessment. Prior to departure into the gulf from LMR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Captain provided voyage plan & navigation assessment and was knowledgeable in difference during attendance.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 11 May 2020 Resolved
The pilothouse alerter system may be reset physically, or the reset may be accomplished by a link to other pilothouse action such as rudder or throttle control movement or motion detection of personnel. Witnessed a line hanging from the ships whistle that could trip the alarm. The line needs to be looped up or made secure. Crew was also unfamiliar with the system and how to turn it on or off and test it. Prior to departure into the gulf from LMR.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Captain removed hanging line and handle and installed hook for the line to prevent movent infront of sensor. Captain knowledgeable of system operation during attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 May 2020 Resolved
Inspections and tests of lifesaving equipment must be recorded in TVR, Official log book or TSMS checklist. Master and Mate unaware of weekly lifesaving equipment checks per 46CFR141.235. Provide weekly checks for the lifesaving equipment. Prior to departure into the gulf from LMR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Weekly checklist provided, logs updated and provided during attendance.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 May 2020 Resolved
The following vessels must have a properly installed, operational, type approved AIS as of the date specified: Chief Mate did not update the AIS and was reflecting 09 persons on board, draught was incorrect and did not know how to update it to reflect current status. Ensure the crew make necessary changes and know the system process. Prior to departure into the gulf from LMR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Captain knowledgeable with AIS operations and correctly updated paramters during attendance.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 May 2020 Resolved
Each towing vessel operating on oceans must carry a Category 1, 406 MHz satellite Emergency Position Indicating Radio Beacon that meets the requirements of 47CFR part 80. The owner or manageing operator must maintain valid proof of registration. The document provided to NOAA had the incorrect length, type of vessel and 2nd 24 hour phone number. Company must update with current information. Prior to departure to the gulf from LMR.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: EPIRB registration provided with accurate information during attendance.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 May 2020 Resolved
Essential systems or equipment must be regularly tested and examined. Test and examinations must verify that the system or equipment functions as designed. Crew were not testing or properly logging test of General alarm, pilothouse alerter system, and emergency lighting. Provide proper documentation of testing of essential equipment and ensure crew understand testing intervals. Prior to departure into the gulf from LMR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 June 2020
Resolution: Captain provided official logs of testing of General Alarm, pilothouse alert. E-lighting under different deficiency.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 11 May 2020 Resolved
Towing vessels must meet the communications requirements of 33CFR part 26 and 33CFR 164.72 as applicable. Marine Inspectors found the bridge to bridge certificate was expired, shore based maintenance was expired, safety radio certificate expired, AC fault, no logs for GMDSS daily, weekly, monthly checks. Bridge to Bridge Prior to movement. All others prior to departure into gulf from LMR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2020
Resolution: Captain provided satisfactory logs and maintenance for Bridge navigation & communication equipment.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2020 Resolved
A 40 B:C portable fire extinguisher must be located near the storage room or cabinet. This is addition to the portable fire extinguisher required by tables 142.230(d)(1) and 142.230(d)(2) of 142.230. No portable fire extinguisher located near flammable locker in the fuel bunker station.Provide a portable 40 B:C fire extinguisher near the flammable locker by the fuel transfer area. As soon as possible but no later than 1 week.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2020
Resolved 12 June 2020
Resolution: Type 4-A / 80-B:C extinguisher mounted in fuel transfer area with proper labeling.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 May 2020 Resolved
A portable watertight container carried at the operating station. Portable watertight containers for pyrotechnic distress signals must be of a bright color and must be clearly marked in legible contrasting letters at least 0.5” inches high with “DISTRESS SIGNALS” Distress flares were in a green container and not properly marked. Provide proper container and mark properly. 1 week
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2020
Resolved 12 June 2020
Resolution: Containers colored Orange and marked during attendance.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 May 2020 Resolved
Each towing vessel must be operated in compliance with FWPCA, APPS, parts 151, 155, 156 as applicable. The Oily water separator is inoperable, the Sludge tank is at 50% capacity. : empty the sludge tank before it is 75% full 46CFR140.655 and Provide proper certification of the OWS prior to departure into the gulf from the river.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 12 June 2020
Resolution: Witnessed satisfactory operation of OWS system. Witnessed locked out discharge valve. Witness approval certificate for approved Oil Content Meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2020 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch MAWP must be equipped with an indicating pressure gauges and with one or more spring loaded relief valves. Inspector found #2 Air Receiver plugged. Crew corrected on the spot verified operation of the PV valve.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Crew removed plug from pressure relief valve.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 May 2020 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: High bilge levels. STBD bilge alarm was cut and inoperable. Crew rewired the bilge alarm and verified proper operation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Crew fixed the wiring for the bilge alarm.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 May 2020 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings and electrical system. Witnesses an excessive leak of the Port shaft seal. Crew tightened up the shaft packing seal to secure leak.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 May 2020
Resolution: Crew tighted up shaft seal to secure leak.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 May 2020 Resolved
Survival Craft Equipment: Provide minimum equipment for survival if recovery time is expected to be greater than 24 hours. Servicing reports for the inflatable life rafts show that the first aid kits expired in January of 2021 and flares expire in March of 2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
Resolution: New equipment is onboard
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2020 Resolved
A towing vessel whose construction was contracted for prior to January 18, 2000, may use an existing engine room monitoring system (with fire-detection capability) instead of a fire-detection system, if the monitoring system is operable and complies with paragraphs (a)(2) through (7) of this section, and uses detectors listed by an NRTL. Provide documentation attesting to the proper certification of the fire detection panel.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
Resolution: Class verified the installation of the fire control panel
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 May 2020 Resolved
All U.S.-flag vessels which engage in domestic voyages by sea (coastwise and intercoastal voyages) shall be subject to the applicable provisions of this part. Route is limited to within the boundary line until proof of valid load line is received and approved by the cognizant OCMI.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 November 2021
Resolution: Approved ABS Load Line submitted
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 9 May 2020 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Rescue boat davit is overdue for 5 year davit servicing. Additionally, the electrical systems within the control box are inoperable. Prove proper operation of the davit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2021
Resolution: Witness satisfactory rescue boat davit test. System operational.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 May 2020 Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Crew no longer has access to their Health and Safety plan (SMS).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2021
Resolution: Reviewed health and safety plan.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 May 2020 Resolved
One ship station license will be granted for operation of all maritime services transmitting equipment on board a vessel. Vessel's Station license is expired.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2021
Resolution: Verified presence of valid station license
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2020 Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Several life rings, as identified by MIs on 6SEPT2021, throughout the vessel needed Bung Holes replaced.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 November 2021
Resolution: Life rings replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 9 May 2020 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. While onboard MIs witnessed an abundance of spiders throughout the tug and barge unit, including several sightings of black widow spiders. Provide crew onboard with the means to control the population to eradicate the presence of deadly spiders.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 November 2021
Resolution: Vessel was clear of all spiders.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2020 Resolved
Vsl Shall comply with 46 CFR subchapter M requirements prior to departure.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2021
Resolution: Vessel was issued a COI
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 10 August 2019 Resolved
The vessel does not currently have a valid DOC and the COI is revoked.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2019
Resolved 15 October 2019

Casualty record · 6

22 March 2016Routine · role: Involved in a Marine Casualty · activity 5864220
17 August 2016Routine · role: Involved in a Marine Casualty · activity 5975235
29 June 2023Routine · role: Involved in a Marine Investigation (non-casualty) · activity 7726320
11 September 2023Routine · role: Involved in a Marine Casualty · activity 7795575
12 May 2024Routine · role: Involved in a Marine Casualty · activity 7911655
2 June 2024Routine · role: Involved in a Marine Casualty · activity 7941114
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DONNA J. BOUCHARD (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.