Records from 2015 to 2025. Most recent: inspection, 14 July 2025.
Documentation record
Registered dimensions (L × B × D)34.3 ft × 10.6 ft × 6.0 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2015
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
14 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8185358
28 February 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8083449
28 February 2025
COI Inspection · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8086080
20 March 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7879532
10 November 2023
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7831742
28 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7640022
3 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7631490
18 July 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7510061
8 March 2022
Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7407793
11 February 2021
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7132410
7 August 2020
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7043131
2 March 2020
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6904627
16 July 2019
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6752598
12 February 2019
Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6618506
18 May 2018
Damage Survey · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6430600
18 May 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6443109
27 March 2018
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6379844
30 March 2017
Annual Inspection · DAPI Audit · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6117309
17 November 2016
DAPI Audit · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6043179
15 June 2016
Annual Inspection · Administrative Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5907061
20 November 2015
Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5791572
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. Vessel must complete a drydock examination and an internal structural examination prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2025
Resolution: Sector Charleston conducted drydock inspection and issued drydock credit on 11March2025.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 February 2023
Resolved
The high water visual indicators for the parachute stowage space and engine room are not operational (audible alarms work). Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 February 2023
Resolved
Mark the ring life buoy with the vessels name in block capital letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2019
Resolved
Replace cutlass bearing, rubber has detached from bearing housing.
Action required: 705 - Other - as specified
Resolved 13 February 2019
Resolution: New Cutlass installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2019
Resolved
Repair/replace propeller, corrosion was found at hub in multiple areas at a depth of 1/16in, believed to be from excess cavitation.
Action required: 705 - Other - as specified
Resolved 13 February 2019
Resolution: Replaced prop installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 May 2018
Resolved
Repair/renew turbo coolant hose. Proivide tech report once repairs are complted. Provide statement from master that witnesses U/W test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2018
Resolution: Hose replaced and tech report provided.
Electrical › Electrical Distribution System (service) › Fuse
Issued 27 March 2018
Resolved
CP01 - Replace all ATO type fuses with fuses of a cartridge type.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 22 May 2018
Resolution: Fuses replaced with cartridge type.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 March 2018
Resolved
CP02 - Renew the following publications with up to date publications. U.S Coast Pilot, Coast Guard light list, Tide tables, and current tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 22 May 2018
Resolution: Publications onboard
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 March 2018
Resolved
CP03 - Display sign stating "COI and Stability letter, available upon request from Captain or crew"
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2018
Resolved 22 May 2018
Resolution: Sign provided.
Lifesaving › Lifebuoys › Stowage
Issued 17 November 2016
Resolved
Make lifering readily accessible and stowed in a way to be easily cast loose
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 29 December 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 November 2016
Resolved
Provide first aid kit with all required contents
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 21 November 2016
Resolution: Procured new first aid kit
Communications › Radio Communications › VHF Radiotelephone
Issued 17 November 2016
Resolved
Program vessel radio with new MMSI
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 21 November 2016
Resolution: Programmed radio with MMSI
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 November 2016
Resolved
Label bilge high level indicators
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 21 November 2016
Resolution: Labeled indicators
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 November 2016
Resolved
Properly mark stern with vessel's hailing port
Action required: 705 - Other - as specified
Due 17 December 2016
Resolved 21 November 2016
Resolution: Marked hull with hailing port
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 June 2016
Resolved
Bilge high level alarm did not audibly or visually alarm.
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 15 June 2016
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 November 2015
Resolved
Vessel is restricted to operations only within 03 miles of the island of Key West for a short duration while taking the place of a delayed new construction vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 February 2016
Resolved 19 February 2016
Resolution: Vessel has completed service in KW AOR.